DIAGNOSTIC STATUS CODES
IT TRANSISTOR CONTROL
Page
34
TRACTION
STATUS CODE
DESCRIPTION OF STATUS
CAUSE OF STATUS INDICATION
-66
The field current exceeds the current
limit of the field transistor.
This status code will be displayed when the field
transistor exceeds its current limit. The line contactor
will drop out and the key switch will have to be
recycled to restart the control.
MEMORY RECALL
YES
CORRECTIVE ACTIONS
TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Traction
Controller
SYMPTOM
Control will not operate or is sluggish on
start up. Line contactor opens.
POSSIBLE CAUSES
•
Shorted field F1 to F2
•
F1 or F2 terminals shorted to battery
positive (B+) or to battery negative (B-)
•
Binding line contactor
•
Visually inspect tips, clean them with a
solvent.
•
Blown FU1 fuse.
•
Noise
•
Confirm that all inductive
loads/accessories are suppressed.
•
Excessive motor and control heating
(controls are in thermal cutback)
FU5
KEY SWITCH
L
SEAT
SW
./
CH
A
R
G
E
R
ST
AR
T SW
.
F
O
RWA
RD S
W
.
R
EVER
SE SW
.
BRAKE SW.
B
SW
1
SW
2
P1
P17
P2 P6
P9
P3
P7
P8
P4
P5
P10
P21
ACC POT
BUZZER
P18
P15
PLUG PY
CONNECTIONS
OSCILLATOR CARD
+5V
NEG
PY11
PY12
P14 P20
TACH
P12
P22
P23
RS
-232
FU1
POWER
CONNECTIONS
POS
A1
F1
NEG
A2
F2
FI
E
L
D
AR
M
ATU
R
E
A2
A1
FU6
LINE
+
-
TRACTION
STATUS CODE
DESCRIPTION OF STATUS
CAUSE OF STATUS INDICATION
-67
The armature current exceeds the
armature transistor limit.
This status code will be displayed when the armature
transistor exceeds its specific current limit. The
control is reset by recycling the key switch.
MEMORY RECALL
YES
CORRECTIVE ACTIONS
TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Traction
Controller
SYMPTOM
Control will not operate.
POSSIBLE CAUSE
•
Shorted motor armature A1 to A2
•
Power cables may be shorted to
each other (Measure at control
terminals)
•
A1 to A2 terminals may be shorted
to battery positive or negative
FU5
KEY SWITCH
L
SEAT
SW
./
CH
A
R
G
E
R
ST
AR
T SW
.
F
O
RWA
RD S
W
.
R
EVER
SE SW
.
BRAKE SW.
B
SW
1
SW
2
P1
P17
P2 P6
P9
P3
P7
P8
P4
P5
P10
P21
ACC POT
BUZZER
P18
P15
PLUG PY
CONNECTIONS
OSCILLATOR CARD
+5V
NEG
PY11
PY12
P14 P20
TACH
P12
P22
P23
RS
-232
FU1
POWER
CONNECTIONS
POS
A1
F1
NEG
A2
F2
FI
E
L
D
AR
M
ATU
R
E
A2
A1
FU6
LINE
+
-
November 2005