ADJUSTABLE FEATURES
SX TRANSISTOR CONTROLS
Page
32
May 2000
Section 5.3 Setup Function Procedures
With the Handset connected, hold down the
CONT
key and
turn on the key switch. This will place you in the setup
mode, ready to monitor or adjust control function settings.
NOTE: The term “Push” means to depress key for
approximately one second.
Section 5.3.1 Setup Mode
SET-UP MODE
Hold Down CONT
And Turn On Key
8 8 8 8
Segment Check
Displayed
ACTION
DISPLAY
SHOWS
REMARKS
Push Function Number
U 0 0 5
Selected Function No.
Is Displayed
After One Second
Time Delay
0 8 5
Stored Value For The
Function Is Displayed
Push CONT
0 8 5
Display Value
Will Blink
Change Value with
Adjustment Knob
Value Changes
While Blinking
Push STORE
125
New Value Stored And
Blinking Stops
Push ESC
8 8 8 8
Segment Check
Displayed
125
At this point, another function can be monitored/changed
by pushing another function number, or the vehicle can be
placed in the run mode by holding the
ESC
key down for
one second or longer. The display will return to either the
diagnostics mode, the BDI display, or a blank display (if
BDI is not used and there are no fault codes). The vehicle
can now be operated with the Handset connected or the
Handset can be disconnected before operation.
NOTE: You can return to the segment check mode at any
time, by holding down the ESC key until 8888 appears in
the display.
Section 5.3.2 Status Code Scrolling
The SX family of controllers furnishes a function register
that contains the last 16 “stored status codes” that shut
down vehicle operation (a PMT type fault that is reset by
cycling the key switch) and the battery state of charge
reading at the time the fault occurred. The first of the 16
status codes will be overwritten each time a new status
code occurs. This stored status code register can be
cleared from memory by using the Handset.
-
Key Switch Off
Push ESC and CONT
At The Same Time
Release ESC and CONT
Key
Status Code Displayed
Push CONT Key
Displays Battery
State-Of-Charge When
Fault Occurred
Push CONT Key
Display Hourmeter Reading
When Fault Occurred
Push CONT Key
Push CONT Key
ACCESSING STORED STATUS CODES
WITH GE HANDSET
Section 5.3.3 SX Family Handset, Plug
Connections and Outline Drawing
“Y“ Plug
Handset Cable Part Number - 328A1550ATP1 (12 pin plug)
Handset Part Number - IC3645LXHS1EC2 (12 pin plug)
(includes handset, cable and case)