ADJUSTABLE FEATURES
SX TRANSISTOR CONTROLS
Page 34
July 2001
FUNCTION 27
HOUR METER MINUTES
(Push CONT 12)
This function adjusts the number of 30 second intervals
registering in the hour meter. This function is typically not
set by an OEM, it is usually only read from the register.
Range
0 to 60 minutes
Resolution 0.5 minutes per set unit
Setting
0 to 120
Example
Setting of 60 = 60 x 0.5 = 30 minutes
FUNCTION 28
STORED STATUS CODE COUNT
POINTER
( Push CONT 13)
This register contains the location of the last stored status
code recorded of the 16 stored status codes. These stored
status codes have caused a PMT controller shutdown
and/or disruption of normal vehicle operation.
To determine which stored status code was the last one
recorded, read the number stored in Function 28. Using the
Memory Map for your logic card, match the "stored status
code pointer number" [the number shown in (bold italics)
in the HS (Handset) number column] on the memory map,
with the number obtained from Function 28. This will be the
last stored status code recorded.
Note: When scrolling through the stored status code
register, the register always starts at status code 1 and
scrolls to status code 16. Instructions for scrolling the
register are in section 5.3.2 of this instruction booklet.
FUNCTION 29
HOUR METER TENS AND UNITS
HOURS
SET
( Push CONT 14)
This function allows for the adjustment of the tens and
units hours of the hour meter.
Range
0
to
99
Set
0
to
99
Example
9999 Hours
FUNCTION 30
HOUR METER THOUSANDS
AND HUNDREDS HOURS SET
( Push CONT 15)
This function allows for the adjustment of the thousands
and hundreds hours of the hour meter.
Range
0
to
99
Set
0
to
99
Example
9999 Hours