Mounting Bracket to Cabinet Wall

The bracket can be used as a template for marking the location of the mounting screws. When determining the

location of the bracket make sure you leave 1-1⁄2

″ 

to 2

″ 

of free area under the sumps to allow for sump removal and

enough space on either side to make the tubing connections.

Make Tubing Connections

Run the length of 3⁄8

tubing, connected to the bottom of faucet, to the filter system outlet, Fig.1 in the

Installation Overview 

section. Allow enough slack in the tubing to be able to place the system on the floor in front

of the sink. Measure and cut the end of the tubing square.

Slide a compression nut onto the end of the tubing and push a tubing insert into the tubing.

Connect the tubing and tighten the compression nuts securely.

Repeat the preceding steps to connect a length of tubing between the filter system inlet and the water

supply/saddle valve, Fig. 1 in the 

Installation Overview 

section.

4

3

2

1

CAUTION: 

Never remove sumps with water pressure in the Water Filtration system.

Close the water supply/saddle valve (Fig. 1 and 2A) to the filter.

Open the filtered water faucet.

Turn the sump off of the filter head as shown (use the sump wrench provided). Be careful, the sump 

is full of water. Locate and save the large o-ring seal. Remove and discard the used filter cartridge.
Be sure the inside of the sump is clean. Thoroughly wash with hot, soapy water and rinse.
Remove the wrapper and labels from the new filter cartridge and insert the filter cartridge in the sump. Some

cartridges fit either way, while others fit only one way. Observe markings on the end of the cartridge. The sediment

(FXUSB)

filter cartridge should always be placed in the 

Filter I

sump. 

Lightly lubricate the o-ring seal, in the sump, with clean silicone grease. Be sure it is fully seated in its groove.
Hold the sump up to the filter head, aligning the center hole in the cartridge with the protrusion on the bottom

of the head.

NOTE: 

If the sump will not tighten up to the head, you may have the cartridge in upside down. Take the cartridge

out and check the markings on the end of the cartridge for correct orientation.

Being careful not to cross-thread, turn the sump onto the filter head and hand tighten securely (see Fig. 5).

CAUTION: 

If using the sump wrench to tighten the sump, do not overtighten.

7

6

5

4

3

2

1

Fig. 4

Filter

Ι

Filter

ΙΙ

Sump

Mounting
screws

Tubing
connector

Tubing
connector

Mounting
bracket

Sump

7-9⁄16

1-1⁄2

to 2

10

Summary of Contents for GXSL03B

Page 1: ...nd Installation Faucet GNUT03B GXUT03B and GXSL03B are Tested and Certified by NSF International against ANSI NSF Standard 42 for Particulate Reduction Class I Chlorine Reduction Class I and Taste and...

Page 2: ...you need quality appliances for your home FOR YOUR RECORDS Write the model and serial numbers here You can find them on the sump bracket Staple sales slip or cancelled check here Proof of the original...

Page 3: ...manual must be followed to minimize the risk of property damage or personal injury SAFETY PRECAUTIONS Check with your local public works department for plumbing codes You must follow these guidelines...

Page 4: ...Safety Instructions Installation Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions Customer Service Troubleshooting Tips Installat...

Page 5: ...the o ring seal in the sump with clean silicone grease Be sure it is fully seated in its groove Hold the sump up to the filter head aligning the center hole in the cartridge with the protrusion on th...

Page 6: ...ation system filter elements should be discarded and the filtration system flushed Circumstances that may require flushing the system are Boil water advisory Flooding of the Water Filtration system Lo...

Page 7: ...should be tested periodically to verify that the system is performing satisfactorily Small parts remaining after the installation could be a choke hazard Discard safely Slotted and Phillips screwdrive...

Page 8: ...uctions Operating Instructions Turn off the cold water supply and attach saddle valve as shown in Fig 2B DANGER To protect yourself from serious injury or fatal shock use a battery powered hand drill...

Page 9: ...drill bits may be needed Place small gasket base and large gasket in that order on to the faucet stem Next place lock washer and hex nut onto faucet stud Insert washer into tubing adapter Securely ti...

Page 10: ...llation Overview section 4 3 2 1 CAUTION Never remove sumps with water pressure in the Water Filtration system Close the water supply saddle valve Fig 1 and 2A to the filter Open the filtered water fa...

Page 11: ...supply and open the filtered water faucet Then disassemble the filter and check the o ring for cuts flat spots etc and sealing surfaces for foreign material Clean the o ring and lubricate with clean s...

Page 12: ...ter cartridges contain Turn on the filtered water faucet and allow these black particles activated carbon which is a harmless carbon particles to purge from the cartridge harmless black powder Turn of...

Page 13: ...protection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher washer and dryer range TV VCR and much mo...

Page 14: ...tment Complete and mail your Consumer Product Ownership Registration today Have the peace of mind of knowing we can contact you in the unlikely event of a safety modification After mailing the registr...

Page 15: ...ng Instructions Safety Instructions Installation Instructions NOTE Codes in the state of Massachusetts require installation by a licensed plumber and do not permit the use of the saddle valve For inst...

Page 16: ...2 2 2 0004 WS22X10007 INSERT 3 8 U 2 2 2 0005 WS02X10003 SCREW 10 14 X 1 4 2 2 2 0006 WS22X10002 ELBOW 3 8 NPT X 3 8 2 2 2 0007 WS19X10011 HEAD 2 2 2 0008 WS03X10001 O RING 3 3 8 X 3 5 8 2 2 2 0009 W...

Page 17: ...Notes Customer Service Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions 17...

Page 18: ...ty Instructions Installation Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions Customer Service Troubleshooting Tips Installation...

Page 19: ...nsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts Filter cart...

Page 20: ...substantial discount GE Consumer Service will still be there after your warranty expires Parts and Accessories 800 626 2002 Individuals qualified to service their own appliances can have parts or acc...

Reviews: