INSTALL GROUNDING CLAMP
DANGER:
Failure to properly attach
ground clamp could result in electrical shock
.
If plumbing is metal, to
maintain electrical ground
continuity
in the house cold water piping, install the
included ground clamp as shown.
• Clean pipe with emery paper in the area where
the clamp is to be installed.
• Install grounding clamps as shown, making sure
clamps fit freely around pipe.
• Make sure lock washer is in place.
• Handtighten screw, then one more full turn with
screwdriver.
NOTE:
When replacing an existing softener, also
replace grounding clamps. If removing softener
completely, hard-plumb the water line with same
type of pipes as the original to assure plumbing
integrity and ground continuity over the life of
the home.
6
Ground
clamp
From valve
outlet
To valve inlet
Installation Instructions
9
FLUSH PIPES, EXPEL AIR FROM
SOFTENER AND TEST YOUR
INSTALLATION FOR WATER
LEAKS
(CONT.)
•
Place bypass valve in the “service” position
EXACTLY as follows. KEEP SOFT WATER FAUCETS
OPEN.
SLOWLY pull or slide the valve stem (out) toward
the service position, pausing several times to
allow the softener to pressurize slowly.
•
After about 3 minutes, open a HOT water faucet
for 1 minute, or until all air is expelled, then
close. NOTE:
If water appears cloudy or has salty
taste, allow to run for several more minutes, or
until clear.
•
Close all water faucets.
•
Check your plumbing work for leaks and fix
right away if any are found. Be sure to observe
previous caution notes.
•
Turn on the gas or electric supply to the water
heater. Light the pilot, if applicable.
7
ADD WATER AND SALT TO THE
BRINE TANK
• Lift the salt hole cover. Add about 3 gallons of
water into the tank. Do not add into the brinewell.
• Fill tank with NUGGET, PELLET or coarse SOLAR
water softener salt with a purity of 99.5% or
higher.
Do not use
rock, block, granulated and ice
cream-making salts, or
salt with iron-removing
additives
(except for Diamond Crystal
®
Red•Out
®
brand salt). Maximum salt storage capacity is
approximately 200 lbs. Keep the salt hole cover
closed unless servicing the unit or refilling
with salt.
NOTE:
If the softener is installed in a humid
basement or other damp area, it is better to
fill the
tank with less salt, more frequently.
Eighty to 100
lbs. of salt will last for several months, depending on
water hardness, family size and water softening
system model.
8
FLUSH PIPES, EXPEL AIR FROM
SOFTENER AND TEST YOUR
INSTALLATION FOR WATER LEAKS
CAUTION:
To avoid water or air
pressure damage to softener inner parts, be
sure to do the following steps in exact order.
•
Fully open 2 cold soft water faucets nearby
the softener.
•
Place bypass valve in “bypass” position by
pushing the stem inward.
•
Fully open the house main water pipe shutoff
valve. Observe a steady flow from both faucets
opened above.
7
Summary of Contents for GXSF40H
Page 24: ...24 Notes...
Page 25: ...25 Notes ge com...
Page 26: ...26 Notes...
Page 28: ...28 Parts list...
Page 57: ...57 Notas ge com...
Page 59: ...59 ge com...