background image

29

Parts catalog.

ge.com 

GENERAL ELECTRIC PARTS CATALOG

G

G

X

X

S

S

F

F

3

4

5

0

E

H

REF. NO.

PART NO.

PART DESCRIPTION

(02) (02)

0003

WS35X10001

O-RING SEAL KIT

1

1

0004

WS34X10015

DECAL, FACEPLATE

1

1

0005

WS07X10004

HOSE, DRAIN, 20 FT.

1

1

0007

WS14X10002

DISTRIBUTOR, TOP

1

1

0008

WS14X10001

DISTRIBUTOR, BOTTOM

1

1

0009

WS01X10002

RESIN, 1 CU. FT.

1

1

0010

WS32X10011

RESIN TANK, 9 X 40

1

1

0011

WS31X10022

COVER, TOP W/ LENS

1

1

0012

WS31X10023

FACEPLATE

1

1

0013

WS21X10016

CONTROL

1

WS21X10018

CONTROL

1

0016

WS26X10013

TRANSFORMER WITH 
POWER CORD

1

1

0017

WS31X10021

COVER, SALT HOLE, 
WITH LABELS

1

1

0018

WS33X10001

VAPOR BARRIER

1

1

0019

WS33X10007

RIM

1

1

0020

WS31X10024

COVER, BRINEWELL W/ DECAL

1

1

0021

WS02X10009

NUT

1

1

0022

WS32X10017

BRINEWELL W/ DECAL

1

1

0023

WS02X10027

SCREW

1

1

0024

WS32X10016

TANK, BRINE, ROUND 

1

1

0025

WS18X10003

CLAMP, HOSE

2

2

0026

WS22X10016

ADAPTER, HOSE

1

1

0027

WS22X10017

GROMMET

1

1

0028

WS35X10035

GROUND CLAMP KIT

1

1

0029

WS15X10035

BRINE VALVE ASM.

1

1

0030

WS35X10036

FLOAT, STEM & GUIDE

1

1

0031

WS03X10006

CLIP

1

1

0032

WS15X10006

VALVE BODY, BRINE

1

1

0033

WS03X10007

CLIP

1

1

0034

WS03X10008

SCREEN

1

1

0035

WS07X10002

TUBING ASM.

1

1

0036

WS07X10015

BRINE TUBE ASM.

1

1

0037

WS31X10018

BACK COVER, ELECTRONICS

1

1

0038

WS02X10029

SPACER

1

1

0039

WS02X10030

FACEPLATE SUPPORT

1

1

0055

WS28X10003

RETAINER CLAMP

2

2

0056

WS28X10004

CLAMP

2

2

0101

WS02X10012

SCREW

1

1

0102

WS02X10013

SPACER

1

1

0103

WS21X10003

SWITCH

1

1

0104

WS03X10009

PIN, EXPANSION

1

1

0105

WS02X10014

SCREW

5

5

0106

WS31X10006

COVER, VALVE

1

1

0107

WS03X10010

WAVE SPRING

1

1

0108

WS26X10002

ROTOR & DISC ASM.

1

1

0109

WS19X10004

CAP, VENTURI

1

1

0110

WS03X10011

SEAL, O-RING

1

1

NOTE: 

Codes in the State of Massachusetts require installation by a licensed

plumber and do not permit the use of the saddle valve. For installation, use
plumbing code 248-CMR of the Commonwealth of Massachusetts.

Summary of Contents for GXSF40H

Page 1: ...pa ol empieza en la p gina 33 Sistema Suavizante de Agua ge com 7283934 215C1173P019 49 50176 06 06 JR Write the model and serial numbers here Model ________________ Serial ________________ To find th...

Page 2: ...OPER INSTALLATION Install or store where it will not be exposed to temperatures below freezing or exposed to any type of weather Water freezing in the system will break it Do not attempt to treat wate...

Page 3: ...CONT Use care when handling the softener Do not turn upside down drop drag or set on sharp protrusions Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi nighttime p...

Page 4: ...n be ordered from GE Parts at 800 626 2002 part number WS07X10004 If a rigid valve drain is needed to comply with plumbing codes you can buy the parts needed to connect a 1 2 copper tubing or plastic...

Page 5: ...e cover SALT GOES HERE Brinewell O rings 2 1 NPT male adapter 2 Clips 2 1 female adapter 2 not supplied Clips O rings 2 INLET Hard water to outside faucets Fig 1 CROSSOVER Use if water supply flows fr...

Page 6: ...cut and drain the house water pipes Open both hot and cold faucets at the lowest location possible NOTE For easier installation remove the top cover Release 2 clips at rear of cover Rotate cover forwa...

Page 7: ...ions to the bypass valve and snap clips into place Be sure the clips for the bypass valve and NPT adapters snap into place Pull on the bypass valve and NPT adapters to make sure the parts are held sec...

Page 8: ...tore 4 Drain fitting on valve Valve drain hose FLOOR DRAIN Tie or wire hose in place 11 2 air gap LAUNDRY TUB SUMP Clamp STANDPIPE Blue indicator light Clip 1 4 NPT threads 1 2 O D copper tube not pro...

Page 9: ...run for several more minutes or until clear Close all water faucets Check your plumbing work for leaks and fix right away if any are found Be sure to observe previous caution notes Turn on the gas or...

Page 10: ...the correct model A beep sounds while pressing buttons for control programming One beep signals a change in the control display Repeated beeps mean the control will not accept a change from the butto...

Page 11: ...of brine well inside brine tank see illustration on page 5 3 Press UP or DOWN button to set the SALT LEVEL to correspond to level on yellow indicator in brine tank NOTE Each press of a button changes...

Page 12: ...DE button to return to the normal run display SALT LEVEL SALT LEVEL E SALT LEVEL SIGNALS LOST TIME SIGNAL If time is lost on the display due to power interruption the blue indicator light will flash 4...

Page 13: ...RTANT Press and hold for 3 seconds the faceplate RECHARGE button to start an immediate recharge RECHARGE begins to flash in the display The bleach will be drawn through the water softener and out the...

Page 14: ...l with the hard water Automatic Hard Water Bypass During Recharge Fill Salt dissolved in water is called brine Brine is needed to clean the hard minerals from resin beads To make the brine water flows...

Page 15: ...k during recharge If it becomes plugged with sand dirt etc the water softening system will not work and you will get hard water To get to the nozzle and venturi remove the water softening system top c...

Page 16: ...g system begins an immediate recharge and when over in about two hours you will have a new supply of soft water Once started you cannot cancel this recharge Feature Optional Recharge Controls Feature...

Page 17: ...u are not getting soft water and an error code is not displayed use the procedures below to find the problem First make the following visual checks VISUAL CHECKS 1 Is there electrical power to the out...

Page 18: ...onnect bypass valve from body Check turbine for binding or restriction due to debris If this does not correct the problem the Timer Sensor or Turbine may require replacement 4 Historical data about th...

Page 19: ...alt See Care and cleaning of the water softening system section If the water softening system does not draw brine check nozzle and or venturi dirty or defective defective nozzle and venturi seal nozzl...

Page 20: ...mond Crystal Red Out brand salt Checking the Salt Storage Level and Refilling Your water softening system takes hardness minerals calcium and magnesium out of the water Also it can control some see th...

Page 21: ...Electrical outlet on a circuit that can NOTE The electrical outlet for the softener should be continuously be switched off live so it cannot be accidentally switched off Manual bypass valve in bypass...

Page 22: ...m section page 15 Water is blue color Acidic water in copper plumbing Have the water tested at once after water softening system was installed Water softening system Meter turbine stuck See the Servic...

Page 23: ...rom the unit This is normal into a drain during recharge Water has air bubbles Air in system after installation Will go away after it runs for a while and is cloudy Error Code on control Wiring may ha...

Page 24: ...24 Notes...

Page 25: ...25 Notes ge com...

Page 26: ...26 Notes...

Page 27: ...3 3 3 7 8 9 10 11 12 56 55 17 18 19 20 21 22 38 23 24 25 26 27 28 29 30 31 32 33 34 35 36 4 55 56 999 2 39 5 27 Parts list ge com...

Page 28: ...28 Parts list...

Page 29: ...E 2 2 0026 WS22X10016 ADAPTER HOSE 1 1 0027 WS22X10017 GROMMET 1 1 0028 WS35X10035 GROUND CLAMP KIT 1 1 0029 WS15X10035 BRINE VALVE ASM 1 1 0030 WS35X10036 FLOAT STEM GUIDE 1 1 0031 WS03X10006 CLIP 1...

Page 30: ...AIN HOSE 1 1 0133 WS03X10021 O RING 5 8 X 13 16 1 1 0134 WS03X10022 PLUG FLOW RINSE CONTROL 1 1 0135 WS03X10023 CLIP 1 1 0136 WS26X10003 CAM GEAR 1 1 0137 WS26X10004 BEARING 1 1 0138 WS26X10005 PLATE...

Page 31: ...amage caused by possible defects with this appliance its installation or repair Product not accessible to provide required service This warranty is extended to the original purchaser and any succeedin...

Page 32: ...ated service costs original purchase Service trips to your home to teach you how to use the product Improper installation delivery or maintenance Failure of the product if it is abused misused altered...

Page 33: ...nes 49 Servicio 46 50 52 Sistema de descalcificaci n de agua 46 52 Cuidado y limpieza 53 Consejos para la soluci n de aver as 54 56 Soporte al cliente Garant a 62 Lista de partes cat logo 58 61 Soport...

Page 34: ...no quede expuesto a temperaturas por debajo del punto de congelaci n ni est expuesto a ning n tipo de inclemencias atmosf ricas Si el agua llega a congelarse dentro del sistema ste podr a romperse No...

Page 35: ...e ni lo apoye en protuberancias La presi n de entrada m xima permitida es de 125 psi Si la presi n durante el d a es por encima de 80 psi la presi n nocturna podr a exceder el m ximo Use una v lvula r...

Page 36: ...al 800 626 2002 no de parte WS07X10004 Si necesita una v lvula r gida de drenaje para cumplir con los c digos de plomer a podr comprar las partes necesarias para conectar un drenaje de tuber a de cobr...

Page 37: ...5 cm 2 Clips 2 Clips Aros t ricos 2 ENTRADA Fig 1 V A DE ENLACE sela si el flujo de suministro fluye desde la izquierda Incluya una derivaci n sencilla o de 3 v lvulas Agua dura Agua descalcificada Ha...

Page 38: ...rifos de agua caliente y los de agua fr a en una ubicaci n baja NOTA Para una m s f cil instalaci n remueva la cubierta superior Libere los dos ganchos en la parte posterior de la cubierta Rote la cub...

Page 39: ...y asegure los clips en su lugar Compruebe que los clips para la v lvula de bypass y los adaptadores NPT se aseguran en su lugar Jale la v lvula de bypass y los adaptadores NPT para verificar que las...

Page 40: ...as presiones de entrada entre 20 y 50 psi no eleve m s de 8 pies 2 67 m por encima del piso Para la presi n de entrada por encima de 50 psi la manguera de drenaje podr a levantarse a una altura m xima...

Page 41: ...a o tiene un sabor salado permita que el sistema funcione por unos minutos m s o hasta que se aclare Cierre todos los grifos de agua Inspeccione en b squeda de fugas en la tuber a que se acaba de llev...

Page 42: ...bot n DOWN Luego oprima el bot n MODE modo para aceptar el modelo correcto Un bip sonar mientras usted oprime los botones para la programaci n del control Un bip significa un cambio en la pantalla de...

Page 43: ...ro del tanque de salmuera vea la ilustraci n de la p gina 37 3 Presione el bot n UP o DOWN para fijar el SALT LEVEL nivel de sal que corresponda al nivel en el indicador amarillo en el tanque de salmu...

Page 44: ...T LEVEL E SALT LEVEL SE ALS SE AL DE HORA PERDIDA Si la hora se pierde en la pantalla debido a una interrupci n en el suministro el ctrico la luz indicadora azul se enciende cuatro veces intermitentem...

Page 45: ...comenzar una recarga inmediata El indicador de RECHARGE recarga aparece intermitente en la pantalla El cloro es llevado a trav s del descalcificador de agua Este proceso dura aproximadamente 2 horas 4...

Page 46: ...s llamada salmuera La salmuera es necesaria para limpiar los minerales duros de las diminutas part culas de resina Para formar la salmuera el agua fluye hacia el interior del tanque de sal durante el...

Page 47: ...ente de sal La sal debe estar floja desde arriba hasta el fondo del tanque Tome un palo de escoba o algo parecido y con cuidado emp jelo hacia el interior del dep sito de sal introduci ndolo y sac ndo...

Page 48: ...asta que est n limpios Si es necesario use un cepillo peque o para remover el hierro o la suciedad Tambi n inspeccione y limpie la junta NOTA Algunos modelos tienen un peque o tap n de flujo localizad...

Page 49: ...carga inmediata y cuando termine en unas dos horas usted tendr un nuevo suministro de agua descalcificada Una vez haya iniciado usted no puede cancelar la recarga Funci n Controles opcionales de recar...

Page 50: ...te procedimiento para encontrar la fuente del problema Primero realice las siguientes inspecciones visuales INSPECCIONES VISUALES 1 Hay energ a el ctrica entrando hacia el tomacorriente en el cual el...

Page 51: ...de agua que pasar por el metro El control produce un sonido por cada gal n Si no hay lectura en la pantalla con el grifo abierto revise el sensor Hale el sensor del puerto de salida de la v lvula y p...

Page 52: ...agua 2 Despu s de observar el llenado presione el bot n RECHARGE recarga para llevar al sistema de descalcificaci n de agua al proceso de salado Un flujo lento de agua hacia el drenaje debe comenzar...

Page 53: ...stal Red Out Inspeccione el nivel de almacenamiento de la sal y el rellenado Su sistema de descalcificaci n de agua toma la dureza de los materiales calcio y magnesio y la extrae del agua Tambi n pued...

Page 54: ...El tomacorriente para el interruptor del El tomacorriente est en un circuito que descalcificador debe estar permanentemente conectado para que no no puede ser desconectado pueda ser desconectado accid...

Page 55: ...descalcificaci n de agua El sistema de El sistema de descalcificaci n de No usa tanta sal para regenerarse es muy eficiente descalcificaci n de agua agua es una unidad de demanda no est usando ninguna...

Page 56: ...era de drenaje restringida Limpie y reconecte la manguera Revise en busca de giros en la l nea de drenaje Agua de color La unidad estuvo inoperante Complete los Procedimientos de desinfecci n de la p...

Page 57: ...57 Notas ge com...

Page 58: ...3 3 3 7 8 9 10 11 12 56 55 17 18 19 20 21 22 38 23 24 25 26 27 28 29 30 31 32 33 34 35 36 4 55 56 999 2 39 5 Lista de partes 58...

Page 59: ...59 ge com...

Page 60: ...7 TORNILLO 1 1 0024 WS32X10016 TANQUE DE SALMUERA REDONDO 1 1 0025 WS18X10003 ABRAZADERA DE LA MANGUERA 2 2 0026 WS22X10016 ADAPTADOR DE LA MANGUERA 1 1 0027 WS22X10017 ARANDELA DE GOMA 1 1 0028 WS35X...

Page 61: ...ADURA DE LA 1 1 BOQUILLA VENTURI 0130 WS35X10005 KIT DEL SELLO 3 4 1 1 0132 WS22X10023 ADAPTADOR MANGUERA 1 1 DE DRENAJE PARA DRENAJE 0133 WS03X10021 ARO T RICO 5 8 X 13 16 1 1 0134 WS03X10022 TAP N D...

Page 62: ...causada por defectos posibles de este electrodom stico su instalaci n o reparaci n Producto no accesible para facilitar el servicio requerido Lo que no est cubierto Esta garant a se extiende al compr...

Page 63: ...lamar al 800 626 2224 durante horas normales de oficina GE Consumer Home Services estar a n ah cuando su garant a termine Piezas y accesorios ge com Aquellos individuos con la calificaci n necesaria p...

Page 64: ...fect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories ge com Indivi...

Reviews: