17
To remove an error code: 1.
Unplug transformer.
2.
Correct defect.
3.
Plug transformer in.
4.
Wait for at least 6 minutes. The error code will return if the reason for
the error code was not corrected.
NO SOFT
WATER
CONTROL SHOWS
WRONG TIME AND
DAY, AND/OR IS
FLASHING.
CONTROL
DISPLAY
BLANK.
CONTROL DISPLAY
SHOWS CORRECT TIME
AND DAY AND IS
STEADY.
Check electrical
power to control
(outlet,
transformer,
power cable, all
connections).
Do manual
diagnostics.
NO POWER
POWER OK
REPAIR AS
NEEDED
CONTROL
DEFECTIVE
Do manual
diagnostics
to verify
proper
function.
Electrical power was
off. Reset the correct
time of day.
Investigate reason for
power loss.
GEAppliances.com
Service: Electronic Demand Time Features and Service
If you are not getting soft water, and an error
code is not displayed, use the procedures below
to find the problem. First make the following
visual checks.
VISUAL CHECKS:
1.
Is there electrical power to the outlet the water
softening system transformer is plugged into?
2.
Is there sufficient salt in the storage tank?
3.
Is the softener bypass valve directing water
for soft water service?
4.
Is the valve drain hose open to the drain,
not more than 8
′
above the softener, and
unobstructed? If hose is above 8
′
, see
page 8, step 4.
If you do not find a problem with the visual
checks, continue below.
Service: Timer/Softener, Service Checkout Procedure
ERROR CODE
DISPLAYED
ERR 01
ERR 02
ERR 03
ERR 04
ERR 05
POSSIBLE DEFECT
• Motor
•Position
•Motor
•Position
•Control
inoperative
switch
inoperative
switch or
or wiring
wiring
harness
harness
• Wiring
•Control
•Control
•Control
harness or
connection
to switch
• Position
switch
• Control