Dimensions and Installation Information (in inches) 

Listed by 

Underwriters 

Laboratories

Specification Revised 2/15

GUD27ESSJ/27GSSJ 

GE

®

 27" Unitized Spacemaker

®

 3.2 DOE Cu. Ft. Washer and 5.9 Cu. Ft. Dryer

For complete information, see installation instructions packed with your dryer.
Ducting Materials: 

For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If rigid metal  

duct cannot be used, then UL-listed flexible metal (semi-rigid) ducting can be used (Kit WX08X10077). In special 

installations, it may be necessary to connect the dryer to the house vent using a flexible metal (foil-type) duct.  

A UL-listed flexible metal (foil-type) duct may be used ONLY in installations where rigid metal or flexible metal  

(semi-rigid)  ducting cannot be used AND where a 4" diameter can be maintained throughout the entire length  

of the transition duct. Please see installation instruction packed with your dryer for complete instructions when 

using flexible metal (foil type) ducting.
Exhaust Length Calculation: 

1.  Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, 

add one turn.

2.  The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown  in the table.
For every extra 90° elbow, reduce the allowable vent system length by 10 ft.
Two 45° elbows will be treated like one 90° elbow.
For the side exhaust installations, add one 90° elbow to the chart.
The total vent system length includes all the straight portions and elbows of the system (transition duct 

included)..
Dryers 

must be exhausted to the outside.

Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl 

space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. 

Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint 

and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap 

must also be located at least 12" above the ground or any other obstruction with the opening pointed down.

Special Installation Requirements
Alcove or Closet Installation:
 

• 

If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back. 

• The dryer MUST be exhausted to the outside.

 

•  Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:

 

                0" either side and rear 

                1" front and top

• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 76-1/2

". 

•  Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area 

equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. 

of open area equally distributed.

• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.

Bathroom or Bedroom Installation:

• The dryer MUST be exhausted to the outdoors.

 

•  The installation must conform with the local codes, or in the absence of local codes, 

 

with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.

Minimum Clearances other than Alcove or Closet Installation:

•  Minimum clearances to combustible surfaces

 

               0" either side and rear 

               1" front and top

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

geappliances.com or call GE Answer Center

®

 

service, 800.626.2000.

GUD27 DRYER EXHAUST LENGTH

4" DIA.

4"

4" DIA.

4" DIA.

2-1/2"

RECOMMENDED MAXIMUM LENGTH

Exhaust Hood Types

Recommended

No. of 90º

Elbows

Rigid

Metal

Rigid

Metal

56 Feet

48 Feet

40 Feet

32 Feet

0

1

2

3

42 Feet

34 Feet

26 Feet

18 Feet

Use only for short

run installations

Summary of Contents for GUD27ESSJ

Page 1: ...GE Appliances Date Created 07 14 15 ...

Page 2: ...ombination Speeds are matched to fabric type for great clothes care Auto load sensing with 4 water levels Washer will automatically measure the load size and add just the right amount of water Rotary electronic controls washer Simplify cycle selection Bleach and fabric softener dispensers Solutions are automatically mixed with wash water for bright soft to the touch results Warranty Information La...

Page 3: ...ed for 120 volt operation Gas Requirements GUD27GSSJ Gas Dryer This appliance should be connected to an individual branch circuit with 120 volt single phase 60 Hz electrical service and should be protected by 20 amp time day fuses or circuit breakers This appliance is equipped with a 4 foot long flexible U S listed 20 amp power cord to match a 20 amp receptacle Note Gas Rated input 20 000 BTU HR F...

Page 4: ...e hazard or moisture could cause damage Never terminate the exhaust into a common duct or plenum with a kitchen exhaust since the combination of lint and grease could create a fire hazard Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts bird nesting etc The wall cap must also be located at least 12 above the ground or any other obstruction with the opening pointed d...

Page 5: ...n speed combinations Speeds are matched to fabric type for great clothes care Auto load sensing with 5 water levels Washer will automatically measure the load size and add just the right amount of water Rotary electronic controls washer Simplify cycle selection Bleach and fabric softener dispensers Solutions are automatically mixed with wash water for clean bright soft to the touch results Cycle s...

Reviews: