background image

11

Installation Instructions

CONNECTING DRYER USING 

3-WIRE CONNECTION

CONNECTING AN ELECTRIC DRYER

3-wire Connection

NOT for use in Canada.

DO NOT use for Mobile Home Installations.

NOT for use on new construction.

NOT for use on recreational vehicles.

NOT for use in areas where local codes prohibit 

grounding through the neutral conduction.

CONNECTING DRYER USING 4-WIRE 

CONNECTION (MUST BE USED FOR 

MOBILE HOME INSTALLATION)

NOTE:

 Since January 1, 1996, the National Electrical 

Code requires that new constructions use a 4-wire 

connection to an electric dryer. A 4-wire cord must also 

be used where local codes do not permit grounding 

through the neutral.
3-wire connection is NOT for use on new construction.

1.

 Turn off the circuit breaker(s) (30 amp) or remove 

the dryer’s circuit fuse at the electrical box.

2.

 Be sure the dryer cord is unplugged from the wall 

receptacle.

3.

 Remove the power cord cover located at the lower 

back.

4.

 Remove and discard ground strap. Keep the green 

ground screw for Step 7.

5.

 Install 3/4 in. UL-recognized strain relief to power 

cord entry hole. Bring power cord through strain 

relief. 

6.

 Connect power cord as follows:

 

A.

  Connect the 2 hot lines to the outer screws of the 

terminal block (marked L1 and L2).

 

B.

  Connect the neutral (white) line to the center of 

the terminal block (marked N).

7.

 Attach ground wire of power cord with the green 

ground screw (hole above strain relief bracket). 

Tighten all terminal block screws (3) securely.

8.

 Properly secure power cord to strain relief.

9.

 Reinstall the cover.

NEVER LEAVE THE COVER OFF OF THE 

TERMINAL BLOCK.

NEVER LEAVE THE COVER OFF OF THE 

TERMINAL BLOCK.

1.

 Turn off the circuit breaker(s) (30 amp) or remove 

the dryer’s circuit fuse at the electrical box.

2.

 Be sure the dryer cord is unplugged from the wall 

receptacle.

3.

 Remove the power cord cover located at the lower 

back.

4.

 Install 3/4-in. UL-recognized strain relief to power 

cord entry hole. Bring power cord through strain 

relief. 

5.

 Connect power cord as follows:

 

A.

  Connect the 2 hot lines to the outer screws of the 

terminal block (marked L1 and L2).

 

B.

  Connect the neutral (white) line to the center of 

the terminal block (marked N).

6.

 Be sure ground strap is connected to neutral 

(center) terminal of block and to green ground 

screw on cabinet rear. Tighten all terminal block 

screws (3) securely.

7.

 Properly secure power cord to strain relief.

8.

 Reinstall the cover.

If required, by local code, install external ground 

(not provided) to grounded metal, cold water 

pipe, or other established ground determined by 

a qualified electrician.

Screws 

(2)

Remove ground strap 

and discard. Keep 

green ground screw

Hot 

Wire

Relocate 

green 

ground 

screw 

here

Green 

Wire

3/4” UL  

Recognized 

Strain Relief

4 #10 AWG minimum copper conductors or 120/240V 30A power 

supply cord kit marked for use with dryers and provided with closed 

loop or spade terminals with upturned ends (not supplied).

Hot 

Wire

Neutral 

(white)

Strain 

Relief 

Bracket

Cover

Screw

Screws 

(2)

Hot 

Wire

3/4” UL  

Recognized 

Strain Relief

Hot 

Wire

Neutral 

(white)

Strain 

Relief 

Bracket

Cover

Screw

Green Ground Screw 

& Ground Strap

3 #10 AWG minimum copper conductors or 120/240V 30A power 

supply cord kit marked for use with dryers and provided with closed 

loop or spade terminals with upturned ends (not supplied).

Summary of Contents for GTD84GCSNWS

Page 1: ...t not exceed 4 feet FOR GAS DRYERS ONLY BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTANT Save these instructions for local electrical inspector s use IMPORTANT Observe all g...

Page 2: ...Order on line at GEApplianceparts com 24 hours a day or by phone at 877 959 8688 during normal business hours STEAM WATER HOSES for steam dryer models only ACCESSORIES Order on line at GEAppliancepart...

Page 3: ...he floor for a garage installation Failure to do so can result in death explosion or fire The dryer MUST be vented to the outdoors Minimum clearance between dryer cabinet and adjacent walls or other s...

Page 4: ...n at the same time NOTE Use new inlet hoses never use old hoses 1 Turn the cold water faucet off Remove the washer inlet hose from the washer fill valve connector cold 2 Ensure the rubber flat washer...

Page 5: ...discard old flexible gas connector and ducting material Shut off Valve MATERIALS YOU WILL NEED 4 dia metal elbow Pipe compound or PTFE tape Flexible gas line connector Duct clamps 2 or Spring clamps...

Page 6: ...not exceed 4 feet Use a new CSA International approved flexible gas supply line Never reuse old flexible connectors Install an individual manual shut off valve within 6ft of the dryer in accordance w...

Page 7: ...ER TO THE GAS SUPPLY cont Open the gas shut off valve F Apply pipe compound or PTFE tape to all male threads Shut Off Valve Plugged Tapping CONNECTING THE DRYER TO THE GAS SUPPLY Install a female 3 8...

Page 8: ...down grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This dryer uses a cord having an equipment grounding conductor and a grounding plug T...

Page 9: ...ILL NEED Slip joint pliers Level 4 dia UL listed flexible metal duct if needed Dryer power cord kit not provided with dryer UL rated 120 240V 30A with 3 or 4 prongs Identify the plug type as per the h...

Page 10: ...his dryer must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This dryer uses a co...

Page 11: ...EAVE THE COVER OFF OF THE TERMINAL BLOCK NEVER LEAVE THE COVER OFF OF THE TERMINAL BLOCK 1 Turn off the circuit breaker s 30 amp or remove the dryer s circuit fuse at the electrical box 2 Be sure the...

Page 12: ...ada and the United States only transition ducts that comply with UL 2158A STANDARD FOR CLOTHES DRYER TRANSITION DUCT shall be used Avoid resting the duct on sharp objects For best drying performance 1...

Page 13: ...45 elbows will be treated like one 90 elbow For the side exhaust installations add one 90 elbow to the chart For every additional 90 elbow reduce the allowable vent system length by 10 feet When calcu...

Page 14: ...rflow and should require little or no maintenance to prevent clogging Wall caps must be installed at least 12 above ground level or any other obstruction with the opening pointed down SEPARATION OF TU...

Page 15: ...e screw saved previously to secure the duct in place through the tab on the appliance base ADDING ELBOW AND DUCT FOR EXHAUST TO RIGHT ELECTRIC MODELS ONLY OR LEFT SIDE OF CABINET Preassemble 4 elbow w...

Page 16: ...up before pressing Power Otherwise the display will not come on The dryer is now ready for use 3 Connect standard metal elbows and ducts to complete the exhaust system Cover back opening with the plat...

Page 17: ...ewdriver n Tape tipped putty knife n Small flat blade screwdriver Before you start Unplug the dryer from its electrical outlet Choose the REVERSING THE DOOR instructions A or B for your model A REVERS...

Page 18: ...d in step 3 into the lower left side screw holes and firmly tighten all 4 screws 6 Install the 4 plastic caps removed in step 1 into the 4 right side front panel holes NOTE To return the door to the o...

Page 19: ...oles 2 on the left and 2 on the right 3 Loosen each top hinge screw on right side Remove the door and place it on a protective flat surface to avoid any damage Plastic Cap 4 Left side of front panel L...

Page 20: ...you finish Plug the dryer back into its electrical outlet Door Hang door and tighten screws B REVERSING THE DOOR GLASS PANEL DOOR MODELS cont 6 Remove and swap the 2 plastic caps and the 2 hinges 7 Ro...

Page 21: ...A GAS NICAMENTE ANTES DE COMENZAR Lea estas instrucciones por completo y con detenimiento IMPORTANTE Guarde estas instrucciones para el uso de inspectores el ctricos locales IMPORTANTE Cumpla con tod...

Page 22: ...t Manguera corta adaptador en Y arandelas y WE1M847 Manguera Larga O POR SEPARADO WE1M847 Manguera Larga y WE1M848 Manguera Corta Instrucciones de instalaci n Incline la secadora de costado y saque lo...

Page 23: ...r una explosi n incendio o la muerte Esta secadora DEBE tener una ventilaci n al exterior El espacio libre m nimo entre el armario de la secadora y las paredes adyacentes u otras superficies es 0 sobr...

Page 24: ...sta que est firmemente asentada 5 Aseg rese de que la arandela de goma plana se encuentra en su posici n y coloque una manguera de entrada de agua de 4 a 6 pies de largo puede ser necesario comprarla...

Page 25: ...as y el material del conducto V lvula de cierre MATERIALES NECESARIOS Codo de metal de 4 di metro Compuesto o PTFE cinta para tuber as Conector de tuber a de gas flexible Abrazaderas de tuber a 2 o ab...

Page 26: ...da por CSA International Nunca vuelva a usar conectores flexibles viejos Instale una v lvula de cierre manual individual dentro de 6 pies de la secadora en acuerdo con el C digo Nacional de Gas Combus...

Page 27: ...do del gas F Aplique compuesto para tuber a o cinta PTFE en todas las roscas macho V lvula de apagado Toma a rosca C MO CONECTAR LA SECADORA AL SUMINISTRO DE GAS Instale un codo hembra NPT de 3 8 al f...

Page 28: ...ecadora est instalada en su posici n final Si el circuito tiene un recept culo de 2 clavijas es responsabilidad del propietario de reemplazarlo con un recept culo de 3 clavijas debidamente conectado a...

Page 29: ...IAS Pinzas Nivel Conducto de metal flexible de 4 de di metro si fuese necesario Kit de cable de energ a de la secadora no incluido con la la secadora Clasificado UL de 120 240V 30A con 3 o 4 patas Ide...

Page 30: ...onectado a tierra En caso de mal funcionamiento o aver a la conexi n a tierra reducir el riesgo de descargas el ctricas al brindar un camino con una resistencia menor para la corriente el ctrica Este...

Page 31: ...trav s del alivio de tensi n 5 Conecte el cable de energ a de la siguiente manera A Conecte los dos cables vivos a los tornillos externos del bloque terminal marcado L1 y L2 B Conecte el cable neutra...

Page 32: ...dan aplastar o doblar CONDUCTO DE TRANSICI N DE METAL FLEXIBLE SECADORA DE ROPA DE LA LISTA DE UL Si un conducto de metal r gido no puede ser utilizado entonces un conducto de metal flexible aprobado...

Page 33: ...ser considerados como un codo de 90 Para el escape lateral agregue un codo de 90 a la tabla Para cada codo adicional de 90 reduzca en 10 pies la longitud permisible del sistema de escape En el c lculo...

Page 34: ...obstrucci n con la abertura apuntando hacia abajo SEPARACI N DE CURVAS Para un mejor desempe o separe todas las curvas con 4 pies de conducto recto como m nimo incluyendo la distancia entre la ltima...

Page 35: ...echa s lo modelos a el ctrico Izquierda Parte inferior Vuelva a conectar la porci n cortada A del conducto a la caja del ventilador Aseg rese de que el conducto m s corto se encuentre alineado con la...

Page 36: ...A A TRAV S DE LA PARTE INFERIOR DEL GABINETE NIVELE LA SECADORA ENCHUFE LA SECADORA 1 CONFIGURACI N FINAL 2 INICIO DE LA SECADORA Presione el bot n Power Encendido NOTA Si la secadora ha sido expuesta...

Page 37: ...nta cubierta con cinta n Destornillador de punta plana peque a Antes de Comenzar Desenchufe la secadora del tomacorriente A INVERSI N DE LA PUERTA MODELOS DE PUERTA S LIDA 1 Abra la puerta aproximadam...

Page 38: ...agujeros inferiores del lado izquierdo y apriete firmemente los cuatro tornillos 6 Instale las cuatro tapas de pl stico retiradas en el paso 1 en los 4 agujeros del panel frontal derecho NOTA Para reg...

Page 39: ...s mismas en posiciones opuestas Tapa de pl stico 4 Lado izquierdo del panel frontal Placa ciega Placa de refuerzo 3 Afloje cada tornillo de la bisagra superior en el lado derecho Retire la puerta y co...

Page 40: ...a enchufar la secadora en la salida el ctrica Puerta Sostenga la puerta y ajuste los tornillos Tapa de pl stico 4 Lado derecho del panel frontal B INVERSI N DE LA PUERTA MODELOS CON PANEL DE CRISTAL...

Reviews: