GE GTD69EBPTDG Installation Instructions Manual Download Page 16

EXHAUSTING THE DRYER (cont.)

NEVER LEAVE THE BACK OPENING WITHOUT THE 

PLATE. 

(Kit WE49X22606)

Installation Instructions

SIDE OR BOTTOM VENTING (cont.)

Connect standard metal elbows and ducts to 

complete the exhaust system. Cover back opening 

with a plate (Kit WE49X22606) available from your  

local service provider. Place dryer in final location.

ADDING COVER PLATE TO REAR OF CABINET

ADDING ELBOW AND DUCT FOR EXHAUST TO 

LEFT OR RIGHT SIDE OF CABINET (cont.)

Plate  

(Kit WE49X22606)

 

Apply duct tape as 

shown on the joint 

between the dryer 

internal duct and the 

elbow, and also the joint 

between the elbow and 

the side duct.

Use 4” rigid metal ducting only inside the dryer. 

Internal duct joints must be secured with tape, 

otherwise they may separate and cause a safety 

hazard.

16

DUCT

TAPE

ADDING ELBOW FOR EXHAUST THROUGH 

BOTTOM OF CABINET

 Insert the elbow through the rear opening and 

connect it to the dryer internal duct.

 

Apply duct tape as 

shown on the joint 

between the dryer 

internal duct and the 

elbow, and also the 

joint between the 

elbow and the bottom 

duct.

Internal duct joints must be secured with tape; 

otherwise, they may separate and cause a safety 

hazard.

Duct tape

FINAL SETUP

 LEVEL THE DRYER

 

PLUG

 

DRYER

 

IN

1

2

 DRYER START-UP

Press the Power button.

Power

NOTE: If the dryer has been exposed to 

temperatures below freezing for an extended 

period of time, allow it to warm up before pressing 

Power. Otherwise, the display will not come on.
The dryer is now ready for use.

3

Ensure

 

proper 

ground

 

exists 

before

 

use.

 

Stand the dryer upright near the final location and adjust 

the leveling legs at the corners to ensure the dryer is level 

side-to-side and front-to-back. Then, adjust the two anti-tip 

legs at the front inner corners, taking care that they are 

touching the floor to avoid unit tip over. The installation is not 

complete until this process is finished.

Summary of Contents for GTD69EBPTDG

Page 1: ...ES 800 432 2737 or visit our Web site at GEAppliances ca Fire Hazard WARNING Clothes FOR GAS DRYERS ONLY IN THE COMMONWEALTH OF MASSACHUSETTS THE FOLLOWING INSTALLATION INSTRUCTIONS APPLY Installation...

Page 2: ...e Kit hoses Y adapter washers included OR WE1M847 Long Hose and WE01X22395 Short Hose PM14X10056 Dryer door opening vent brush not included WX14X10007 LintEater Dryer rotary tube brush not included 2...

Page 3: ...immediately upstream of the gas supply connection to the dryer POWER CORDS GE strongly recommends the use of factory specified parts Select the power cord to fit your installation requirements Order...

Page 4: ...the rubber flat washer is in place and attach the dryer s long inlet hose to one male end of the Y connector Tighten by hand until firmly seated 6 Ensure the rubber flat washer is in place and attach...

Page 5: ...F position Disconnect and discard old flexible gas connector and ducting material Shut off Valve MATERIALS YOU WILL NEED 10 Adjustable wrenches 2 8 Pipe wrench Flat blade screwdriver Level Slip joint...

Page 6: ...e sea level Installation must conform to local codes and ordinances or in their absence the NATIONAL FUEL GAS CODE ANSI Z223 Explosion Hazard WARNING Use a new CSA International approved flexible gas...

Page 7: ...SUPPLY cont Open the gas shut off valve F Apply pipe compound or PTFE tape to all male threads Shut Off Valve Plugged Tapping CONNECTING THE DRYER TO THE GAS SUPPLY Install a female 3 8 NPT elbow at t...

Page 8: ...receptacle Ensure proper ground exists before use GROUNDING INSTRUCTIONS This dryer must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by prov...

Page 9: ...p joint pliers Flat blade crewdriver Phillips screwdriver Level TOOLS YOU WILL NEED MATERIALS YOU WILL NEED 4 dia metal elbow 3 4 strain relief UL recognized 4 duct clamps 2 or 4 spring clamps 2 Safet...

Page 10: ...lure to do so can result in death fire or electrical shock GROUNDING INSTRUCTIONS For a grounded cord connected dryer This dryer must be grounded In the event of a malfunction or breakdown grounding w...

Page 11: ...the dryer s circuit fuse at the electrical box 2 Be sure the dryer cord is unplugged from the wall receptacle 3 4 ground screw for Step 7 5 Install 3 4 in UL recognized strain relief to power cord en...

Page 12: ...TOOLS AND MATERIALS YOU WILL NEED TO INSTALL EXHAUST DUCT PARTS AVAILABLE FROM GE APPLIANCES CA OR LOCAL SERVICE ORGANIZATIONS Phillips head screwdriver Duct tape or duct clamp flexible metal 4 10 2...

Page 13: ...ill be treated like one 90 elbow For every additional 90 elbow reduce the allowable vent system length by 10 feet When calculating the total vent system length you must add all the straight portions a...

Page 14: ...nce to the exhaust airflow and should require little or no maintenance to prevent clogging Wall caps must be installed at least 12 above ground level or any other obstruction with the opening pointed...

Page 15: ...ppliance base ADDING ELBOW AND DUCT FOR EXHAUST TO SIDE OF CABINET TAB LOCATION Fire Hazard WARNING Close the back opening with cover plate Kit WE1M454 Disconnect dryer from electrical supply Wear glo...

Page 16: ...ET Insert the elbow through the rear opening and connect it to the dryer internal duct Apply duct tape as shown on the joint between the dryer internal duct and the elbow and also the joint between th...

Page 17: ...putty knife Small flat blade screwdriver Before you start Unplug the dryer from its electrical outlet Choose the REVERSING THE DOOR instructions A or B for your model A REVERSING THE DOOR SOLID DOOR M...

Page 18: ...er left side screw holes and firmly tighten all 4 screws 6 Install the 4 plastic caps removed in step 1 into the 4 right side front panel holes NOTE To return the door to the original setup follow the...

Page 19: ...holes 2 on the left and 2 on the right 3 Loosen each top hinge screw on right side 5HPRYH the door and place it on a protective flat surface to avoid any damage Plastic Cap 4 Left side of front panel...

Page 20: ...dryer back into its electrical outlet Door Hang door and tighten screws B REVERSING THE DOOR GLASS PANEL DOOR MODELS cont 6 5HPRYH DQG VZDS WKH SODVWLF FDSV DQG WKH hinges 7 5RWDWH WKH RXWHU GRRU GHJU...

Page 21: ...ou visitez notre site web www electromenagersGE ca Risque d Incendie AVERTISSEMENT L installation de la s cheuse doit tre effectu e par un installateur qualifi Installez la s cheuse conform ment ces i...

Page 22: ...95 Tuyau Court PM14X10056 Brosse pour sortie d air de s cheuse non inclus WX14X10007 Brosse pour tube rotatif de s cheuse LintEater non inclus 2 DIMENSIONS APPROXIMATIVES Avertissement sur la Proposit...

Page 23: ...tement d utiliser les pi ces sp cifi es du fabricant Choisissez le fil lectrique qui convient aux besoins de l installation Num ro de Pi ce Type Longueur Amp rage WX9X2 3 Broches 4 Pieds 30 WX9X3 3 Br...

Page 24: ...bout en Y Serrez fermement la main 6 S assurez que le joint plat en caoutchouc soit en place et attache l autre embout du long tuyau d arriv e de la s cheuse l embout de la valve de remplissage au bas...

Page 25: ...mat riel des conduits Vanne d Arr t MAT RIAUX DONT VOUS AUREZ BESOIN Cl s molette de10 2 Cl tuyau de 8 Tournevis plat Niveau Pince joint coulissant Coude en m tal de 4 de diam P te joint ou ruban PTFE...

Page 26: ...lle dans les 6ft de la s cheuse conform ment au Code national du gaz combustible ANSI Z223 1 NFPA 54 Serrez fermement tous les embouts de gaz Si raccordez au gaz propane GPL demandez une personne qual...

Page 27: ...F Appliquez de la p te joint ou du ruban PTFE aux filetages m les Vanne d Arr t Bouchon de Tuyau RACCORDEMENT L ALIMENTATION EN GAZ DE LA S CHEUSE Installez un coude femelle de 3 8 NPT au bout du tuya...

Page 28: ...demander un lectricien agr de le remplacer par une prise de mise la terre 3 broches correctement mise la terre Assurez vous que la prise du cable est mise la terre avant de l utiliser INSTRUCTIONS DE...

Page 29: ...evis Phillips Niveau OUTILS DONT VOUS AUREZ BESOIN MAT RIAUX DONT VOUS AUREZ BESOIN Coude en m tal de 4 trier de d charge de traction de 3 4 Brides de conduit de 4 2 ou pinces ressort de 4 2 Lunettes...

Page 30: ...ue INSTRUCTIONS DE LA MISE LA TERRE Pour une s cheuse reli e la terre et connect e par un cordon Cette s cheuse doit tre mise la terre En cas de mauvais fonctionnement ou de panne la mise la terre r d...

Page 31: ...nlevez la protection du fil lectrique situ e 4 Enlevez et jetez la tresse de masse Gardez la vis verte de mise la terre pour l tape 7 5 Installez un trier de d charge de traction de 3 4 po homologu UL...

Page 32: ...ainsi les vitez de placer le conduit sur des objets tranchants CONDUIT DE TRANSITION DE M TAL FLEXIBLE HOMOLOGU UL DE TYPE FEUILLE M TALLIQUE Lors d installations sp ciales il peut tre n cessaire de...

Page 33: ...oude Pour chaque coude additionnel de 90 r duire de 10 pieds la longueur du conduit d vacuation En calculant la longueur totale du conduit d vacuation vous devez ajoutez toutes les portions droites et...

Page 34: ...obstruction Les capuchons de mur doivent tre install s au moins 12 au dessus du niveau du sol ou tout autre obstacle avec l ouverture vers le bas S PARATION DE VIRAGES Pour de meilleures performances...

Page 35: ...ENT LAT RAL DE LA S CHEUSE SITE DE LA LANGUETTE Risque d Incendie AVERTISSEMENT Fermez l ouverture arri re avec une plaque de recouvrement Ensemble WE1M454 D branchez la s cheuse de l approvisionnemen...

Page 36: ...nduit interne de la s cheuse et le coude ainsi que sur le joint entre le coude et le conduit lat ral Les joints de conduits internes doivent tre scell s avec du ruban adh sif sinon ils peuvent se s pa...

Page 37: ...Tournevis plat Avant de commencer D branchez la s cheuse de la prise lectrique Choisissez les instructions INVERSION DE PORTE A ou B pour votre mod le A INVERSION DE PORTE MOD LE DE PORTE SOLIDE 1 Ou...

Page 38: ...c t gauche et serrez fermement les 4 vis 6 Installez les 4 bouchons de plastique enlev s l tape 1 dans les 4 trous du c t droit du panneau avant NOTE Pour retourner la porte son installation originale...

Page 39: ...t 2 droite 3 Desserrez chaque gond sup rieur du c t gauche Enlevez la porte et placez la sur une surface plane pour viter des dommages Bouchon de Plastique 4 C t gauche du panneau avant Desserrez chaq...

Page 40: ...Porte Accrochez la porte et serrez les vis B INVERSION DE PORTE MOD LE DE PORTE EN VERRE suite 6 Enlevez et changez les 2 bouchons de plastique et les deux gonds 7 Faire pivoter la porte ext rieure d...

Reviews: