Installation Instructions
REQUIREMENTS FOR ALCOVE OR
CLOSET INSTALLATION
MOBILE OR MANUFACTURED HOME
INSTALLATION
3
- Explosion Hazard
WARNING
Keep flammable materials and vapors, such as gasoline,
away from dryer.
Place dryer at least 18” (46 cm) above the floor for a
garage installation.
Failure to do so can result in death, explosion, or fire.
If the dryer is approved for installation in an alcove or
closet, it will be stated on a label on the dryer back.
The dryer MUST be vented to the outdoors. See
WKH(;+$867,1*7+('5<(5VHFWLRQ
Minimum clearance between dryer cabinet and
adjacent walls or other surfaces is:
0”
either
side
3”
front
0” rear but a 1” minimum is recommended
Minimum vertical space from dryer to overhead
shelves, cabinets, ceilings, etc., is 1” on top.
Consideration must be given to provide adequate
clearance for installation and service.
Closet doors must be louvered or otherwise
ventilated and have at least 60 square inches of
open area. If the closet contains both a washer
and a dryer, doors must contain a minimum of
120 square inches of open area.
NOTE:
WHEN THE EXHAUST DUCT IS LOCATED IN
7+(5($52)7+('5<(57+(&21),*85$7,212)
7+('8&7,1*0$<5(48,5(*5($7(57+$1µ2)
5($5&/($5$1&($µ0,1,080,65(&200(1'('
Gas Dryers Only:
No other fuel burning appliance shall be installed
in the same closet as a gas dryer.
The dryer must be disconnected from the gas
supply piping during pressure testing at pressures
greater than ½ psi (3.5 kPa).
A 1/8 inch NPT minimum plugged tapping,
accessible for test gauge connection, must be
installed immediately upstream of the gas supply
connection to the dryer.
POWER CORDS:
GE strongly recommends the use of factory specified parts.
Select the power cord to fit your installation requirements.
Order on-line at
GEApplianceParts.com
, 24 hours a day or
by phone at
800.626.2002
during normal business hours.
Part Number
Type
Length
Amperage
WX9X2
3-Prong
4 Feet
30
WX9X3
3-Prong
5 Feet
30
WX9X4
3-Prong
6 Feet
30
WX9X18
4-Prong
4 Feet
30
WX9X19
4-Prong
5 Feet
30
WX9X20
4-Prong
6 Feet
30
MINIMUM CLEARANCE OTHER THAN
ALCOVE OR CLOSET INSTALLATION
Installation must conform to the
0$18)$&785('+20(&216758&7,21$1'
6$)(7<67$1'$5'7,7/(3$57²RU
Standard CAN/CSA-Z240 MH, or, when such
VWDQGDUGLVQRWDSSOLFDEOHZLWK$0(5,&$1
1$7,21$/67$1'$5')2502%,/(+20(
ANSI/NFPA NO. 501B.
The dryer MUST be vented to the outdoors. The
exhaust vent must be securely fastened to a
non-combustible portion of the mobile home.
The vent MUST NOT be terminated beneath a
mobile or manufactured home.
The vent duct material MUST BE METAL.
KIT 14-D346-33 MUST be used to attach the dryer
securely to the structure.
The vent MUST NOT be connected to any other
duct, vent or chimney.
Do not use sheet metal screws or other
fastening devices which extend into the interior
of the exhaust vent.
Provide an opening with a free area of at least
25 square inches for introduction of outside air
into the dryer room.
See the sections for electrical connection
information.
Minimum clearance to combustible surfaces and
for air opening are: 0” both sides; 1” front; 0” rear
but a 1” minimum is recommended. Consideration
must be given to provide adequate clearance for
installation and service.