GE GSD3301K00BB Installation Instructions Manual Download Page 5

The improper connection of the   equipment- 

grounding conductor can result in electric 

shock. Check with a qualified electrician or 

service representative if you are in doubt 

that the appliance is properly grounded. 

Do not modify the plug provided with the 

appliance; if it will not fit the outlet, have 

a proper outlet installed by a qualified 

technician.

WARNING

Cabinet Preparation and Wire Routing

• The wiring may enter the opening from either side, 

rear or floor within the shaded area illustrated 

above in Figure E and defined in Figure A.

• Cut a 1-1/2" maximum diameter hole to insert the 

electrical cable. Permanent wiring connections 

may pass through the same hole as the drain 

hose and hot water line, if convenient. Hole edges 

must be smooth and rounded. If the cabinet wall is 

metal, the hole edge must be covered with a cord 

protector.  

NOTE: Power cords with plug must pass through a 

separate hole. 

PREPARE ELECTRICAL WIRING

Electrical Requirements

• This appliance must be supplied with 120V, 60 Hz., 

and   connected to an individual properly grounded 

branch circuit, protected by a 15- or 20-ampere 

circuit breaker or time-delay fuse.

• Wiring must be 2 wire with ground.

• If the electrical supply does not meet the above 

 requirements, call a licensed electrician before 

 proceeding.

Grounding Instructions – Permanent Connection

This appliance must be connected to a grounded- 

metal, permanent wiring system, or an equipment- 

grounding conductor must be run with the circuit 

conductors and be connected to the equipment- 

grounding terminal or lead on the appliance.

Grounding Instructions – Power Cord Models

This appliance must be grounded. In the event of a 

malfunction or breakdown, grounding will reduce 

the risk of electric shock by providing a path of 

least resistance for electric current. This appliance 

is equipped with a cord having an equipment- 

grounding conductor and a grounding plug. The 

plug must be plugged into an appropriate outlet 

that is installed and grounded in accordance with 

all local codes and ordinances.

White

18"

6"

24"

from Wall

3"

from

Cabinet

Alternate
Receptacle
Location

Ground

Black

1-1/2" Dia. Hole (Max.)

18"

6"

Receptacle
Location
Area

Figure E

Installation Preparation – Electrical Supply

FOR PERSONAL SAFETY: Remove house fuse 

or open circuit breaker before beginning 

installation. Do not use an extension cord 

or adapter plug with this appliance.

Electrical Connection to Dishwasher

Electrical connection is on the right front of 

dishwasher.

• For permanent connections, the cable must 

be routed as shown in Figure E. The cable must 

extend a minimum of 24" from the rear wall.

• For power cord connections, install a 3-prong 

grounding-type receptacle in the adjacent cabinet 

rear wall, between 6" and 18" from the opening, 6" 

to 18" above the floor as shown in Figure E. 

Hole Diameter

1-1/2" Maximum

Cord

Protector
(Provided

with Power

Cord Models Only)

Metal Cabinet Wall

PARA SEGURIDAD PERSONAL: Retire el 

fusible de la casa o abra el interruptor de 

circuitos antes de empezar la instalación. 

No use un cable de extensión o enchufe 

adaptador con este aparato.

La conexión incorrecta del conductor 

de conexión a tierra del equipo puede 

resultar en choque eléctrico. Consulte con 

un electricista calificado o representante 

de servicio si tiene dudas de la conexión 

a tierra del aparato. No modifique el 

enchufe que se suministra con el aparato; 

si no calza en el tomacorrientes, haga 

que un técnico calificado le instale un 

tomacorrientes adecuado.

ADVERTENCIA

WARNING

WARNING

ADVERTENCIA

5

Summary of Contents for GSD3301K00BB

Page 1: ...l CAUTIONS and WARNINGS shown throughout these instructions While performing installations described in this booklet gloves and safety glasses should be worn READ CAREFULLY KEEP THESE INSTRUCTIONS IMP...

Page 2: ...untertops FOR NEW INSTALLATIONS Electrical cable Water line 3 8 minimum copper tubing including ferrule and compression nut Strain relief for electrical connection Hand shut off valve recommended Air...

Page 3: ...or to open fully Refer to Figure B 0DNH VXUH WKH RRU LV OHYHO LQVLGH WKH RSHQLQJ DQG HYHQ ZLWK WKH QLVKHG RRU RI WKH NLWFKHQ 7KLV ZLOO facilitate removal of the dishwasher at a later date for service...

Page 4: ...drain loop will result in improper draining of the dishwasher which may cause damage Installation Preparation Drain Remove Drain Plug PREPARE DRAIN PLUMBING Drain Requirements Follow local codes and o...

Page 5: ...a malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This appliance is equipped with a cord having an equipment grou...

Page 6: ...r connection is on the left side of the dishwasher Install the hot water inlet line using 3 8 or larger copper tubing Route the line as shown in Figure F and extend forward at least 19 from rear wall...

Page 7: ...mix up with the 1 4 machine thread screws in Step 20 Figure H STEP 1 PREPARATION Locate the items in the installation package and set them aside for use in the listed steps Screw kit Steps 5 or 16 an...

Page 8: ...GE appliance dealer meets these requirements Dishwasher Installation STEP 7 INSTALL DRAIN HOSE TO DISHWASHER DRAIN PORT Skip this step if drain hose has been preinstalled In this step you will need t...

Page 9: ...USED THROUGH CABINET Upright the dishwasher and position it in front of the cabinet opening Insert the drain hose into the hole previously drilled in the cabinet wall If a power cord is used guide th...

Page 10: ...damage Do not press on the center of panel with hands or knees when sliding dishwasher into position Figure Q STEP 12 POSITION AND LEVEL DISHWASHER IMPORTANT Dishwasher must be level for proper dish...

Page 11: ...SUPPLY Connect the water supply line to the 90 elbow installed in Step 6 Slide the compression nut and then the ferrule over the end of the water line Insert the water line into the 90 elbow Slide th...

Page 12: ...HG WR W WKH LQOHW SRUW If a longer drain hose is required and you did not purchase the GPF10S drain hose add up to 42 length for a total of 120 10 feet to the factory installed hose Use 5 8 or 7 8 ins...

Page 13: ...r cord with plug is already installed proceed to Step 17 If the dishwasher came with a factory installed power cord and you want to convert it to a permanent connection refer to the instructions on pa...

Page 14: ...drain push the reset pad on electronic models For dial models un ODWFK WKH GRRU DQG URWDWH WKH GLDO WR WKH 2 position STEP 19 DISHWASHER WET TEST CHECKLIST Turn on power supply or if power cord is use...

Page 15: ...hwasher Remove the two 8 32 x 1 4 machine thread screws Align the access panel to the dishwasher Select the two 8 32 x 1 4 machine thread screws just removed and insert them through the top holes in t...

Page 16: ...and remove cover if present Disconnect the three power cord conductors from the dishwasher harness See Figure BB Remove and discard the power cord Connect the conversion harness included with dishwas...

Page 17: ...s directives il faut porter des gants et des lunettes de s curit VEUILLEZ LIRE ATTENTIVEMENT ET CONSERVER CES DIRECTIVES IMPORTANT Observez tous les codes et ordonnances en vigueur Note l installateur...

Page 18: ...limentation en eau tuyau en cuivre d au moins 9 5 mm 3 8 po y compris bague et crou compression Bague anti traction pour le raccordement lectrique Robinet d arr t recommand Coupure anti refoulement po...

Page 19: ...um 3 m tres 10 pieds de l vier pour assurer une YLGDQJH DGpTXDWH Le dessus les c t s et l arri re du lave vaisselle doivent tre compl tement dissimul s l int rieur GH O RXYHUWXUH Le lave vaisselle ne...

Page 20: ...vidange doit avoir une longueur PD LPDOH GH PqWUHV SLHGV Il faut pr voir une boucle de vidange lev e RX O LQVWDOODWLRQ G XQH FRXSXUH DQWL UHIRXOHPHQW 9RLU FL GHVVRXV M thode de vidange Le type d inst...

Page 21: ...nissant au courant lectrique un circuit GH PRLQGUH UpVLVWDQFH HW DSSDUHLO HVW GRWp G XQ cordon d alimentation poss dant un conducteur GH PLVH j OD WHUUH HW XQH ILFKH GH PLVH j OD WHUUH La fiche doit t...

Page 22: ...t peut m me tre exig e par les codes locaux en YLJXHXU Le raccordement de la conduite d eau s effectue GX F Wp JDXFKH GX ODYH YDLVVHOOH QVWDOOH OD conduite d eau chaude en utilisant un tuyau HQ FXLYUH...

Page 23: ...po j O pWDSH TAPE 1 PR PARATION Prenez les pi ces fournies dans l emballage et mettez les de c t en vue de les utiliser au cours GHV pWDSHV LQGLTXpHV FL GHVVRXV Ensemble de vis tapes 5 ou 16 et 13 Cou...

Page 24: ...tion GX 1DWLRQDO OHFWULFDO RGH GHV e 8 HW RX DX RUGRQQDQFHV HW DX FRGHV ORFDX HQ YLJXHXU Le cordon d alimentation doit avoir une longueur PD LPDOH GH P SL H FRUGRQ G DOLPHQWDWLRQ n WX09X70910 ou WX09X...

Page 25: ...rais de r paration inutiles pour des probl mes de remplissage de vidange ou de bruit Placez la conduite d eau et le c ble lectrique de mani re ce qu ils n entrent pas en contact avec quoi que ce soit...

Page 26: ...2 MISE DE NIVEAU DU LAVE VAISSELLE IMPORTANT Le lave vaisselle doit tre de niveau pour assurer le bon fonctionnement des paniers et de la porte du lave vaisselle et obtenir XQH ERQQH H FDFLWp GH ODYDJ...

Page 27: ...se ferme facilement sans frotter contre les armoires DGMDFHQWHV 9LVVH FRPSOqWHPHQW OHV YLV ELHQ GURLWHV Figure T Support du comptoir 1 9 cm 3 4 po Supports de montage lat raux facultatifs TAPE 13 FIX...

Page 28: ...z pas achet le boyau de vidange GPF10S ajoutez au boyau de vidange install l usine une longueur maximale de 106 cm 42 po SRXU XQH ORQJXHXU WRWDOH GH PqWUHV SR Pour ce faire utilisez un boyau dont le d...

Page 29: ...ave YDLVVHOOH SRXU OXEULILHU OH MRLQW GH OD SRPSH 2XYUH O DOLPHQWDWLRQ HQ HDX FKDXGH 9pULILH V LO D GHV IXLWHV 6HUUH OHV UDFFRUGV DX EHVRLQ 5HSRUWH YRXV j O pWDSH Enlevez la pellicule protectrice s il...

Page 30: ...la porte et WRXUQH OH VpOHFWHXU j OD SRVLWLRQ 2 UUrW TAPE 19 LISTE DE CONTR LE DE L ESSAI DU LAVE VAISSELLE AVEC DE L EAU R tablissez l alimentation lectrique ou si l appareil est dot d un cordon d al...

Page 31: ...HOOH Prenez les deux vis m taux n 8 32 x 6 3 mm 1 4 po que vous venez d enlever et vissez les dans les trous la partie sup rieure du panneau G DFFqV HW GDQV OH FDGUH GX ODYH YDLVVHOOH 6HUUH ELHQ FHV Y...

Page 32: ...D branchez les trois conducteurs du cordon G DOLPHQWDWLRQ GX IDLVFHDX GX ODYH YDLVVHOOH 5HSRUWH YRXV j OD LJXUH QOHYH HW MHWH OH FRUGRQ G DOLPHQWDWLRQ UDQFKH OHV OV SRXU OD FRQYHUVLRQ IRXUQLV DYHF le...

Reviews: