Service Factors (US only)
* For a motor with a servicefactor of
1.15 or greater, use
the motor nameplate full load
current to select the
appropriate current range.
*
For motors with a service
factor less than 1.15, multiply
the motor FLA by .9 and
select the appropriate current range.
These instructions do not purpose to cover all details or variations in equipment nor to provide for every possible contingency to be met in
connection with installation operation or maintenance. Should further information be desired or should particular problems arise which
are not covered sufficiently for the purchaser's purposes, the matter should be referred to the GE Company.
GE Industrial Systems
41 Woodford Ave.
Plainville, CT 06062
GE Power Controls
©2000 General Electric Company
* Per UL 508 sec. 76.10, short circuit indication is required for category E installation of GPS2BHA. Use catalog # GPAE11LLA.
6.3
10
Characteristic curve
Operating Temperature at 20
Max. Value
Min. Value
0.001
2 3 4 5 6 78 10
Multiple of rated current
20 30 4050 70 100
0.002
0.004
0.006
0.01
0.02
0.04
0.06
0.1
0.2
Operating
time
second
minute
0.4
0.6
1
2
4
6
10
20
40
1
2
4
6
10
20
40
60
120
180
Instantaneous
tripping
characteristic
1100% to 1560%
of maximum current
Max. total fault
clearing time
Catalog Number
Standard breaking capacity High breaking capacity
Adjustment Range
GPS2BSAK
6.3 - 10
GPS2BSAL
9 - 13
GPS2BSAM
11 - 16
14 - 20
GPS2BSAN
19 - 25
GPS2BSAP
24 - 32
GPS2BSAR
28 - 40
GPS2BSAS
35 - 50
GPS2BSAT
GPS2BSAU
GPS2BHAK
GPS2BHAL
GPS2BHAM
GPS2BHAP
GPS2BHAN
GPS2BHAR
GPS2BHAS
GPS2BHAT
GPS2BHAU
45 - 63
GPAPTP2A
Click
9
9
90
110
84
120
3.3
91±1
107.8
55±0.5
42
M4X10
Screw fitting
5.5
92.3
4.2
18
AWG
20
13
Wire size
1 - 6 mm
2
10 - 25 mm
2
18 - 8 AWG
6 - 4 AWG
Terminal cover
No cutting
Cut before mounting
( part A and B )
( 2.5 mm
2
)
( 1.5 mm
2
)
( 14 AWG )
( 16 AWG )
20
13
( 1.5 mm
2
)
( 1.0 mm
2
)
20
13
A
B
part A
part B
* Per UL 508 sec. 76.10, short circuit indication is required for category E
installation. Use catalog # GPAE11LLA.
* Suitable for motor group installation on a circuit capable of delivering not
more than shown below, when protected by 1500A maximum Fuses or Circuit
Breaker.
240V
6.3 - 10
9 - 13
11 - 16
14 - 20
19 - 25
24 - 32
28 - 40
35 - 50
45 - 63
480V
600V
100,000
100,000
100,000
100,000
100,000
100,000
100,000
100,000
100,000
65,000
65,000
65,000
65,000
65,000
65,000
65,000
65,000
35,000
25,000
25,000
25,000
25,000
25,000
25,000
10,000
10,000
10,000
GPS2BHAK
GPS2BHAL
GPS2BHAM
GPS2BHAN
GPS2BHAP
GPS2BHAR
GPS2BHAS
GPS2BHAT
GPS2BHAU
GPS2BSAK
GPS2BSAL
GPS2BSAM
GPS2BSAN
GPS2BSAP
GPS2BSAR
GPS2BSAS
GPS2BSAT
GPS2BSAU
Catalog Number
RMS Symmetrical Amperes
FLA Adjustment
Range