Problem
Possible Causes
What To Do
Water hard sometimes
Using hot water while the water
• Avoid using hot water during water softening system
softening system is regenerating
regeneration because the water heater will refill with hard water.
Control
HARDNESS
number setting
• Press the
SET
button to enter a new value. Be sure the
too low
number shown is the same as the actual grains per gallon
hardness of your water supply
. See the
Programming
the Control
section if a change in the setting is needed.
Grains of hardness in your water
• Water hardness can change over time, especially in well water.
supply have increased
To check, have the water tested by a water analysis laboratory
or call your local water department. Adjust the hardness
number setting as needed.
System capacity inputs, Salt per
• See
Salt per Regen and Capacity
section so system will
Regeneration and Capacity set too low
regenerate about every 5 days. See instructions on pages 12
and 13.
If resin bed is fully exhausted, for
• Complete “back to back” regenerations. Initiate Regeneration
example, after a malfunction, one
cycle, wait 1 minute, then press
REGEN
again.
regeneration cycle may not fully
See page 14.
restore capacity
Water feels slippery
Absence of hardness minerals
• This is normal. Hardness in water gives it the abrasive feel
after installation of
you may have been accustomed to. The slippery feel is the
water softening system
clean feel of soft water.
Water softening system
Water softening system is a
• Does not use much salt to regenerate—very efficient.
not using any salt
“demand” unit
Possible salt bridge
• See the
Breaking a Salt Bridge
section.
Possible plugged injector and screen
• See the
Cleaning the Injector and Screen
section.
Water is blue color
Acidic water in copper plumbing
• Have the water tested at once.
after water softening
system was installed
Cloudiness on glassware
Combination of soft water and
• This is called
etching
and is permanent. To prevent this
(automatic dishwashers)
too much detergent
from happening, use less detergent if you have soft water.
Wash glassware in the shortest cycle that will get them clean.
Excessive/high level
Valve drain hose pinched,
• Any restriction in this drain hose may prevent proper
of water in brine tank
plugged, elevated too high
operation of the injector and screen and reduce or prevent
or otherwise restricted
brine draw during regeneration.
Injector or injector screen dirty
• See the
Cleaning the Injector and Screen
section, page 17.
With water pressure to the water softening system off,
remove the injector and injector screen. Thoroughly clean
and flush. Check for any damage. Reassemble to valve
assembly.
Before you call for service…
20
Troubleshooting Tips