Installation Instructions
4
3
RECONNECTING GAS
NEW METAL
FLEXIBLE GAS
LINE CONNECTOR
ADAPTER
ELBOW
ITEMS NOT SUPPLIED
ADAPTER
SHUT-OFF
VALVE
PIPE SIZE
AT LEAST 1/2"
1/8" NPT PIPE
PLUG FOR
CHECKING GAS
INLET PRESSURE
3/8" NPT
Listed connector ANSI Z21.24 / CSA 6.10
only on the original installation and are not to be reused
end of adaptor free of grease, oil and thread sealant.
CAUTION:
Use adaptors as shown. Connector nuts
must not be connected directly to pipe threads.
APPLY PIPE COMPOUND
TO THE ADAPTER AND
DRYER GAS INLET.
Tighten the flexible
gas line using two
adjustable wrenches.
APPLY PIPE COMPOUND
TO ALL MALE THREADS.
Tighten all connections using two adjustable
wrenches.
Do not overtorque gas connections!
Check all connections for leaks with soapy solution or equivalent.
Apply soap solution. Leak test solution must not contain ammonia
which could cause damage to the brass fittings. If leaks are found.
close valve, retighten the joint, and repeat the soap test.
4
LEAK TEST
NEVER
USE AN OPEN FLAME TO TEST FOR
GAS LEAKS.
OPEN
GAS VALVE.
WARNING