GE GFDS350GLWW Installation Instructions Manual Download Page 4

Installation Instructions

4

6

 EXHAUST INFORMATION

EXHAUST SYSTEM CHECK LIST

HOOD OR WALL CAP

•  Terminate in a manner to prevent back drafts or entry of 

birds or other wildlife.

•  Termination should present minimal resistance to 

the exhaust air flow and should require little or no 

maintenance to prevent clogging.

•  Never install a screen in or over the exhaust duct. This 

could cause lint build up.

•  Wall caps must be installed at least 12 in. above ground 

level or any other obstruction with the opening pointed 

down.

SEPARATION OF TURNS

For best performance, separate  all turns by at least 4 ft. 

of straight duct, including distance between last turn and 

exhaust hood.

TURNS OTHER THAN 90º

•  One turn of 45º or less may be ignored.

•  Two 45º turns should be treated as one 90º turn.

•  Each turn over 45º should be treated as one 90º turn.

WARNING -

 IN CANADA AND IN THE 

UNITED STATES, THE REQUIRED EXHAUST 

DUCT DIAMETER IS 4 in (102mm). DO NOT 

USE DUCT LONGER THAN SPECIFIED IN THE 

EXHAUST LENGTH TABLE.

Using exhaust longer than specified length will:

• Increase the drying times and the energy cost.

• Reduce the dryer life.

• Accumulate lint, creating a potential fire hazard.

The correct exhaust installation is YOUR 

RESPONSIBILITY. Problems due to incorrect 

installation are not covered by the warranty.

Remove and discard existing plastic or metal foil 

transition duct and replace with UL listed transition duct.

The MAXIMUM ALLOWABLE duct length and number of 

bends of the exhaust system depends upon the type of 

duct, number of turns, the type of exhaust hood (wall 

cap), and all conditions noted below. The maximum duct 

length for rigid metal duct is shown in the table below.

EXHAUST LENGTH

4" DIA.

4"

4" DIA.

Exhaust Hood Types

.

No of 90º

Elbows

Rigid

Metal

90 Feet

60 Feet

45 Feet

35 Feet

25 Feet

0

1

2

3

4

RECCOMMENDED MAX.

 

LENGTH

5 ELECTRICAL CONNECTION INFORMATION

 WARNING -  TO REDUCE THE RISK 

OF FIRE, ELECTRICAL SHOCK, AND  

PERSONAL INJURY: 

•  DO NOT USE AN EXTENSION CORD 

OR AN ADAPTER PLUG WITH THIS 

APPLIANCE.

 

Dryer must be electrically grounded in accordance 

with local codes and ordinances, or in the absence 

of  local codes, in accordance with the NATIONAL 

ELECTRICAL CODE, ANSI/NFPA NO. 70.

ELECTRICAL REQUIREMENTS

This appliance must be supplied with 120V, 60Hz, and 

connected to a properly grounded branch circuit, pro-

tected by a 15- or 20-amp circuit breaker or time delay 

fuse. If electrical supply provided does not meet the 

above specifications, it is recommended that a licensed 

electrician install an approved outlet.

 WARNING -  THIS DRYER IS 

EQUIPPED WITH A THREE-PRONG 

(GROUNDING) PLUG FOR YOUR PROTEC-

TION AGAINST SHOCK HAZARD AND 

SHOULD BE PLUGGED DIRECTLY INTO A 

PROPERLY GROUNDED THREE-PRONG 

RECEPTACLE. DO NOT CUT OR REMOVE 

THE GROUNDING PRONG FROM THIS 

PLUG.

IF LOCAL CODES PERMIT,

AN EXTERNAL GROUND WIRE

(NOT PROVIDED), WHICH MEETS

LOCAL CODES, MAY BE ADDED

BY ATTACHING TO THE GREEN

GROUND SCREW ON THE REAR

OF THE DRYER, AND TO A GROUNDED

METAL COLD WATER PIPE OR OTHER

ESTABLISHED GROUND.

ENSURE PROPER GROUND EXISTS BEFORE USE

Summary of Contents for GFDS350GLWW

Page 1: ...sit our Web site at www GEAppliances com US BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTANT Save these instructions for local inspector s use IMPORTANT Observe all governing codes and ordinances Note to Installer Be sure to leave these instructions with the customer Note to Customer Keep these instructions with your Use and Care Book for future reference Before the old ...

Page 2: ...EL GAS CODE ANSI Z223 This gas dryer is equipped with a Valve Burner Assem bly for use only with natural gas Using conversion kit WE25X0217 your local service organization can convert this dryer for use with propane LP gas ALL CONVER SIONS MUST BE MADE BY PROPERLY TRAINED AND QUALI FIED PERSONNEL AND IN ACCORDANCE WITH LOCAL CODES AND ORDINANCE REQUIREMENTS The dryer must be disconnected from the ...

Page 3: ...ealant CAUTION Use adaptors as shown Connector nuts must not be connected directly to pipe threads APPLY PIPE COMPOUND TO THE ADAPTER AND DRYER GAS INLET Tighten the flexible gas line using two adjustable wrenches APPLY PIPE COMPOUND TO ALL MALE THREADS Tighten all connections using two adjustable wrenches Do not overtorque gas connections Check all connections for leaks with soapy solution or equ...

Page 4: ...LLOWABLE duct length and number of bends of the exhaust system depends upon the type of duct number of turns the type of exhaust hood wall cap and all conditions noted below The maximum duct length for rigid metal duct is shown in the table below EXHAUST LENGTH 4 DIA 4 4 DIA Exhaust Hood Types No of 90º Elbows Rigid Metal 90 Feet 60 Feet 45 Feet 35 Feet 25 Feet 0 1 2 3 4 RECCOMMENDED MAX LENGTH 5 ...

Page 5: ...azard Do not use duct longer than specified in the exhaust length table Longer ducts can accumulate lint creating a potential fire hazard Never install a screen in or over the exhaust duct This will cause lint to accumulate creating a potential fire hazard Do not assemble ductwork with any fasteners that extend into the duct These fasteners can accumulate lint creating a potential fire hazard Do n...

Page 6: ...K Stand the dryer upright near the final location and adjust the 4 leveling legs at the corners to ensure that the dryer is level from side to side and front to rear For many applications installing elbows at both the dryer and the wall is highly recommended see illustrations below Elbows allow the dryer to sit close to the wall without kinking and or crushing the transition duct maximizing drying...

Page 7: ...MUST be vented to the outdoors with the termination securely fastened to the mobile home structure See EXHAUST INFORMATION section 6 The vent MUST NOT be terminated beneath a mobile or manufactured home The vent duct material MUST BE METAL KIT 14 D346 33 MUST be used to attach the dryer securely to the structure The vent MUST NOT be connected to any other duct vent or chimney Do not use sheet meta...

Page 8: ...elbow as shown above DUCT TAPE CAUTION Use 4 rigid metal ducting only inside the dryer Internal duct joints must be secured with tape otherwise they may sepa rate and cause a safety hazard ADDING COVER PLATE TO REAR OF CABINET Connect standard metal elbows and ducts to complete the exhaust system Cover back opening with a plate Kit WE1M454 available from your local service provider Place dryer in ...

Page 9: ... Siga todos los códigos y ordenanzas vigentes Nota al instalador Asegúrese de dejar estas instrucciones con el consumidor Nota al consumidor Mantenga estas instrucciones con el Manual de uso y cuidados para referencia futura Antes de que la secadora antigua sea retirada del servicio o elimi nada quítele la puerta La información sobre reparaciones y el diagrama del cableado se en cuentran en la con...

Page 10: ...anzas locales o si no las hubiera con el CÓDIGO NACIONAL DE GAS ANSI Z223 Esta secadora a gas está equipada con un montaje de válvula y quemador para utilizar sólo con gas natural Mediante el kit de conversión WE25X0217 la organización de atención local puede convertir esta secadora para su uso con gas propano LP TODAS LAS CONVERSIONES DEBEN LLEVARLAS A CABO PERSONAL CAPACITADO Y CALIFICADO EN CUM...

Page 11: ...exión no deben conectarse directa mente en las roscas de la tubería APLIQUE COMPUESTO PARA TUBERÍA AL ADAPTADOR Y A LA ENTRADA DE GAS DE LA SECADORA Ajuste la tubería flexible de gas utilizando dos llaves ajustables APLIQUE COMPUESTO PARA TUBERÍA EN TODAS LAS ROSCAS MACHO Ajuste todas las conexiones mediante dos llaves ajustables No ajuste de más las conexiones de gas Controle todas las conexiones...

Page 12: ...ad de codos del sistema de salida dependen del tipo de conducto la cantidad de curvas la clase de campana de salida cubierta de pared y todas las condiciones indicadas a continuación La longitud máxima del conducto para conductos rígidos de metal se indica en la siguiente tabla 4 DIA 4 4 DIA 90 Feet 60 Feet 45 Feet 35 Feet 25 Feet 0 1 2 3 4 LONGITUD DE SALIDA LONGITUD MÁXIMA RECOMENDADA Tipos de c...

Page 13: ... de una longitud mayor a la especificada en la tabla de longitud de salida Los conductos más largos acumulan pelusa lo que genera un riesgo potencial de incendio Nunca instale un filtro dentro o sobre el conducto de salida Esto provocará la acumulación de pelusas lo que genera un riesgo potencial de incendio No arme la red de conductos con sujeciones que se extiendan dentro del conducto Estas suje...

Page 14: ...LAR FRENTE A PARTE TRASERA Stand the dryer upright near the final location and adjust the 4 leveling legs at the corners to ensure that the dryer is level from side to side and front to rear Para muchas aplicaciones se recomienda enfáticamente la instalacióndecodosenlasecadorayenlapared verilustraciones de abajo Los codos permiten que la secadora se ubique cerca de la pared sin torcer o aplastar e...

Page 15: ...norma no sea aplicable con la NORMA NACIONAL ESTADOUNIDENSE PARA CASAS MÓVILES ANSI NFPA Nº 501B La secadora DEBE tener ventilación al exterior con la terminación bien sujeta a la estructura de la casa móvil Ver la INFORMACIÓN SOBRE SALIDA sección 6 La ventilación NO DEBE terminar debajo de una casa móvil o prefabricada El material del conducto de ventilación DEBE SER METAL DEBEutilizarseelKIT14 D...

Page 16: ...A PRECAUCIÓN Utilice un conducto de metal rígido de 4 sólo dentro de la secadora Las juntas del con ducto interno deben sujetarse con cinta caso contrario pueden separarse y provocar un riesgo de seguridad CÓMO AGREGAR LA PLACA DE CUBIERTA A LA PARTE TRASERA DEL GABINETE Conecte los codos y conductos de metal estándar para completar el sistema de salida Cubra la abertura trasera con la placa Kit W...

Reviews: