![background image](http://html1.mh-extra.com/html/ge/ges-nx25in/ges-nx25in_owners-manual-and-installation-instructions_4683649013.webp)
Indoor Unit Installation
Make holes of 60 mm in diamet er.
Ins tall piping hole cove r and sea l it off with putty after ins tallation
F itting of the Mounting P late and P ositioning of the wall Ho le
Making a Ho le on the Wall
Indoor side
O utdoor side
Ø 60mm
Wall hole
T hickne ss of wall
( S ection of wall hole)
12
1. Fix mounting plate on the wall horizontally.
2. Positoning the piping hole at position shown at figure.
The different shape of mounting plate has its position.
1.
2.
A=170mm
C=120mm
B= 60mm
B= 60mm
1
2
3
4
3. F a ste n securely the plate with stee l nails o f the reference holes 1, 2 , 3
4. Che ck care fully to make s ure the ins tallation s ecure.
P reparation of indoor unit body
1
2
3
1. Take out cushion blocks on the left
and right angle beads as shown in
the following . The cushion blocks are no longer used.
2. Remove 2 cushions between the
cross-flow fan and the casing
3. There are 3 virtual segments on the case. Select the required virtual
segment on the case according to the piping outside direction .
Remove it by hands
and clean the burr
to let the power cable (with the plug)
pass through.
P reparation of piping and conne cting wiring
4
1
Cut the connecting wirings 1.5m longer than the pipe
length.
Cut the pipes a little longer than measured distance.
Measure the distance between the indoor and the
outdoor unit.
Use the accessory piping kit or the pipes.
Cut the pipes and cables
Turn the pipe end down to avoid the metal
powder entering the pipe.
2
Remove the burrs
3
Insert the flare nuts,mounted on the connection
Fit the copper end into the Bar of flare tool
Flare the pipe end.
Flaring the pipe.
Conne ction of piping
5
1.Align the center of the piping and sufficiently tighten
2.Finall y, tighten the flare nut with torque wrench until
the wrench clicks.
When tightening the flare nut with torque wrench ,
ensure the direction for tightening follows the arro
w
on the wrench.
and 4. In case of left rear piping, please find the wall hole location A.
In case of right rear piping, please find the wall hole location C.
500
144
70
183
500
76
60mm
60mm
60mm
60mm
GES-NX25IN
GES-NX35IN GES-NX1H25IN
GES-NX25IN M GES-NX35IN M
GES-NX50IN GES-NX2G50IN GES-NX2G70IN
GES-NX1H35IN GES-NX2G25IN GES-NX2G35IN GES-NX2G25IN M
GES-NX2G35IN M
Summary of Contents for GES-NX25IN
Page 2: ......
Page 3: ......
Page 6: ......
Page 7: ......
Page 8: ......
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 14: ......
Page 15: ......
Page 16: ......
Page 17: ......
Page 18: ......
Page 20: ......
Page 21: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 29: ......
Page 30: ......
Page 32: ......
Page 33: ......
Page 34: ......
Page 35: ...1 230V...
Page 36: ......