background image

IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.

WARNING

Risk of electric shock. Can cause injury or death. For your
safety, the information in this manual must be followed to
minimize the risk of fire, electric shock or personal injury.

Use this appliance only for its intended purpose as
described in this Owner’s Manual.

This air conditioner must be properly installed in
accordance with the Installation Instructions before it
is used.

Never unplug your air conditioner by pulling on the
power cord. Always grip plug firmly and pull straight
out from the receptacle.

If the supply cord is damaged,it must be replaced
by the manufacture,its service agent or similarly 

damaged power supply cord must be replaced
with a new power supply cord obtained from the
manufacturer and not repaired. Do not use a cord
that shows cracks or abrasion damage along its
length or at either the plug or connector end.

NOTE:

All servicing should be performed by a qualified

individual.

For your safety…do not store or use combustible
materials, gasoline or other flammable vapors or
liquids in the vicinity of this or any other appliance.

All air conditioners contain refrigerants, which under
federal law must be removed prior to product
disposal. If you are getting rid of an old product
with refrigerants, check with the company handling

disposal about what to do.

SAFETY PRECAUTIONS

SAVE THESE INSTRUCTIONS

For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock,

or to prevent property damage, personal injury, or loss of life.

This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.  All safety 

messages will follow the safety alert symbol and the word “DANGER”, “WARNING”, or “CAUTION”.  These words are defined as:

Indicates a hazardous situation which, if not avoided,

will

result in death or serious injury.

  Indicates a hazardous situation which, if not avoided,

could

result in death or serious injury.

  Indicates a hazardous situation which, if not avoided,

could

result in minor or moderate injury.

SAFETY INFORMATION

WARNING

DANGER

CAUTION

WARNING

qualified persons in order to avoid a hazard. A

Turn

OFF

and unplug your air conditioner before

performing any user maintenance or cleaning.

This appliance can be used by children aged 8 years
and above and persons with reducedphysical,
sensory or mental capabilities or lack of experience

and knowledge if they have been given supervision
or instruction concerning use of the appliance in a
safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made
by children without supervision.

Always keep the remote control and its batteries out
of the reach of children and infants, including during
normal use and when replacing worn out batteries.

Worn out batteries should be discarded safely and

in accordance with local regulations.

Do not obstruct or cover the ventilation grille of the
air conditioner.

Do not remove the fan guard.

Do not place fingers or other items near the ventilation
grille whilst the product is still connected to the

electricity supply.

Do not repeatedly removed and re-insert the mains plug in order stop and start the product.
Do not place anything on top of the Indoor Unit.

Do not hang anything from the Indoor Unit.

Do not attach anything to the Indoor Unit.

When cleaning the Indoor Unit NEVER pour water over the product. Do not use means to accelerate the defrosting process or 

When cleaning the Indoor Unit NEVER use a dripping wet cloth. Always make sure the cloth is either dry or slightly damp.

1

to clean, other than those recommended by the manufacturer.

The appliance must be stored in a room without continuously operating ignition sources (for example: open flames, an operatin

g

gas appliance or an operating electric heater). Do not pierce or burn. Be aware that refrigerants may not contain an odour.

The appliance must be installed, operated and stored in a room with a floor area larger than 3 M

2

Summary of Contents for GES-NJGB25IN-1

Page 1: ...BLE SHOOTING 15 Write the model and serial numbers here Model _________________________ Serial ____________________________ 1 SAFETY INFORMATION SPECIFICATIONS 16 This appliance is filled with R32 GES...

Page 2: ...azardous situation which if not avoided could result in death or serious injury Indicates a hazardous situation which if not avoided could result in minor or moderate injury SAFETY INFORMATION WARNING...

Page 3: ...TRUCTIONS BEFORE USING WARNING RISK OF FIRE Could cause serious injury or death DO NOT use an adaptor plug with this Air Conditioner DO NOT use surge protectors or multi outlet adaptors with this Air...

Page 4: ...Used to set HEAT operation Used to set COOL operation QUIET button n o i t c n u f h c a e f o y a l p s i D status Operation mode display TEMP display Humidity display FAN SPEED display SWING display...

Page 5: ...GES NJGB25IN 1 GES NJGW25IN GES NJGB35IN 1 1 GES NJGW35IN 1 GES NJGB50IN GES NJGW50IN GES NMG25IN GES NMG35IN GES NMG50IN GES NMG70IN GES NM25IN M GES NM35IN M...

Page 6: ...is needed for rest or reading For each press is displayed Air conditioner starts QUIET function operation In QUIET operation mode fan speed automatically takes low speed of AUTO fan mode Press QUIET...

Page 7: ...ssed temp setting decreases 1 C 1 2 1 POWER POWER Operation Press POWER Operation Powerful function available in heating and cooling mode after unit turn on SMART HEALTH AIRFLOW POWER LIGHT CODE DRY F...

Page 8: ...midity a phenomenon falling drips of water occurs at the outlet grille 5 Select the appropriate fan direction according to the actual conditions 7 SMART HEALTH AIRFLOW POWER LIGHT CODE DRY FAN MODE SL...

Page 9: ...occur at air outlet if all vertical louvers are adjusted to left or right position for a long time in COOL or DRY mode otherwise condensate water might occur 1 2 HEAT SMART Initial state Initial stat...

Page 10: ...se by 2 C further After more another 3 hours temp rises by 1 C further The unit will run for further 3 In SMART mode The unit operates in corresponding sleep mode which adapted to the automatically se...

Page 11: ...NFIRM CANCEL SWING QUIET COOL HEAT TEMP TEMP FAN FAN SPEED AUTO AUTO AUTO ON OF F Operation Use this operation only when the remote controller is defective or lost and with function of emergency runni...

Page 12: ...luoresecent lamps If the remote control is fixed to a wall locate it in a location where the signal is not affected by fluorescent light starting devices The distance between the indoor unit and the f...

Page 13: ...e plug pass through Preparation of piping and conne cting wiring 4 1 Cut the connecting wirings 1 5m longer than the pipe length Cut the pipes a little longer than measured distance Measure the distan...

Page 14: ...e warm area to prevent condensation Problems with the piping may lead to water leaks and interior property damage 2 Do not install the drain pipe as follows It is raised after exiting the wall The end...

Page 15: ...e water out of the cloth before wiping then wipe off the detergent completel y Air Filter cleaning Open the inletgrille by pulling it upward R emove the filter C lean the filter Attach the filter C lo...

Page 16: ...ownout Is the air filter dirty Are there any obstacles before Is temperature set correctly Are there some doors or Is there any direct sunlight through the window during the Are there too much heat so...

Page 17: ...d for charging Important information regarding the In accordance with the directive of the European parliament herewith we inform the consumer about the dis posal requirements of the electrical and el...

Reviews: