2 Safety Measures & Warning

• The GEP inverter strictly conforms and has been tested according to international safety 

regulations. 

• The manufacturer strongly advises installers to follow local safety regulations during 

commissioning, operation and maintenance of the GEP inverter. Improper operation may result in 
electric shocks or damage to equipment and property.

• The installation, maintenance and connection of the inverters must be performed by qualified 

personnel, in compliance with local electrical standards, regulations and following the regulations 
of the local power suppliers, companies and related authorities. 

•  If the GEP inverter is unpacked but not put into use immediately,  please put it back to the original 

package with the desiccant bag and seal it with tape.

• To avoid electric shocks, the DC input and AC output port of the inverters must be disconnected 

for at least 5 minutes before performing any installation or maintenance.

• The temperature of some components of the inverters may exceed 60

 during operation. To 

avoid burns, do not touch the inverter during operation. Let the inverter cool before operating.

• Keep children away from the inverter. 
• Touching or changing inverter components without following manual instructions may cause 

personal injury, damage the inverters and could ultimately invalidate the warranty.

• The electronic components of the inverter could be damaged by static electricity. Appropriate 

methods must be adopted to prevent such damage, otherwise the warranty may be null and void. 

• Ensure the output voltage of the proposed PV array is lower than the maximum rated input voltage 

of the inverter, otherwise the inverter may be damaged and the warranty may be null and void. 

• When exposed to sunlight, the PV array generates dangerously high DC voltage. We strongly 

advise operators strictly follow instructions and avoid actions that put lives at risk. 

• The PV modules should have as a minimum an IEC61730 class A rating protection. 
• If the equipment is used in a way not authorized by the manufacturer, the equipment built-in 

protections may be damaged. 

• In order to achieve complete equipment isolation: turn off the AC switch first, then turn off the DC 

switch.

• Do not insert or pull the AC or DC terminals when the inverter is in operation.  
• An Arc Fault Detector is recommended to be installed on the DC side of an earthing photovltaic 

system.

• The inverter can exclude the possibility of DC residual currents to 6mA in the system, Where an 

external RCD is required in addition to the built-in RCMU, type A RCD must be used to avoid 
tripping. 

• The PV is not grounded as default configuration. 

Failure to observe a warning indicated in this manual may result in 

injury.

Danger of high voltage & electric shock.

This side up. The package must always have the arrows point up.

Special disposal instructions.

Refer to operation instructions

.

CE mark.

1 Symbols

Don't touch, hot surface!

No more than four  identical packages stacked on each other.

Fragile.

Wait at least 5 minutes after disconnecting the inverter before 

handling internal parts

.

Keep Dry.

Recyclable materials.

4

5min

01

02

Summary of Contents for GEP5.0C

Page 1: ...3 support au gesolarinverter com sales au gesolarinverter com Global Sales Service Network GEP 4 6 10KW SINGLE PHASE USER MANUAL GE is a registered trademark of General Electric Company and is used un...

Page 2: ...l Connection 08 4 4 Communication Connection 12 5 System Operation 16 5 1 LCD Panel 16 5 2 User Interface and System Configuration 17 5 3 Wi Fi LAN Reset Wi Fi LAN Reload 22 5 4 Precaution for Initial...

Page 3: ...d to prevent such damage otherwise the warranty may be null and void Ensure the output voltage of the proposed PV array is lower than the maximum rated input voltage of the inverter otherwise the inve...

Page 4: ...y extension solution for our customer For further details please visit www gesolarinverter com Item 1 2 3 4 5 6 7 8 9 Name DC Switch PV Input Terminal Wi Fi LAN Module Optional DRED Function Optional...

Page 5: ...be installed near flammable and explosive items Strong electro magnetic charges should be kept away from installation site 4 Product label and warning symbols should be located and placed in a manner...

Page 6: ...Grade A B C D Description Outside diameter Separated wire length Conductor wire length Conductor core section Value 13 18mm 20 25mm 7 9mm 2 5 10mm2 D A B Annealed copper wire C Cables Screw cap AC sh...

Page 7: ...PE wire ground wire Not following this instruction may cause damage to the inverter 5 Red wire represents positive black wire represents negative 6 For the GE series the minimum insulation resistance...

Page 8: ...d metal parts of the equipment and other enclosures in the PV power system must be grounded Please follow the steps below to connect PE cable to ground L1 L2 L1 1 2mm Step 1 Strip the wire insulation...

Page 9: ...installations in compliance with Australian and New Zealand safety requirements and DRED is not provided by the manufacturer DRED should be connected to the COM port with 6 Pin as illustrated below P...

Page 10: ...ion of commu nication connection you can access portal gesolarinverter com or download the Power Sight App by scanning the QR code to monitor your PV plant and device Please contact after sales for fu...

Page 11: ...6000W Or Or Power Limit ON Pac 6000W Power Limit OFF Pac 6000W Set Power Limit XXX Set Power Limit XXX Set Modbus Addr Pac 6000W Short Press Long Press Short press short press to select Leading or Lag...

Page 12: ...E Today menu which displays the total power generation for today Short press the button to enter the E Total menu which displays the total power generation up to today Short press the button to enter...

Page 13: ...et Power Limit XXX Long press 2S 6 Operation of display under grid connected mode When the input voltage reaches the inverter s start up voltage the LCD starts to work the yellow light will be turned...

Page 14: ...ecifically according to the inverter Modbus address and Modbus register value according to the set range to set the corresponding value PF Power Curve Mode Function PF curve mode enable or disable B P...

Page 15: ...e refer to the following instructions before contacting your local service If any problems arise the red FAULT LED indicator on the front panel will light up and the LCD screen will display relevant i...

Page 16: ...s possible that there are special characters not supported by the module in the hotspot password Please modify the password so that it consists of only Arabic numerals or uppercase lowercase letters...

Page 17: ...20 360 80 600 0 13 13 13 16 3 16 3 16 3 3 1 1 1 4600 4600 230V 50 20 3 150 120 80 97 7 97 3 GEP7 0S 13500 600 80 550 80 120 360 80 600 0 13 13 13 16 3 16 3 16 3 3 1 1 1 7000 7000 230V 3 50 1 35 1 Adju...

Page 18: ...es Moisture Location Category Definition Environment Category Definition Outdoor the ambient air temperature is 20 50 Relative humidity range is from 4 to 100 applied to PD3 Indoor unconditioned the a...

Reviews: