![background image](http://html.mh-extra.com/html/ge/gep-09ca/gep-09ca_installation-and-user-manual_2198926006.webp)
•
Exhaust
Nozzle (1)
•
Exhaust
Hose (1)
•
Hose Connector
(1)
•
Flat Screws (2)
1
for extension panels
1
for nozzle
•
Remote Control
LOCATION REQUIREMENTS
•
Place the air conditioner on a flat level surface in a
location that is at least 51 cm
from any wall.
NOTE:
A minimum clearance of 51 cm
from the
air
conditioner to the wall must be maintained to
ensure
proper airflow
•
Maintain a minimum 51 cm
clearance around the air
conditioner to not block airflow
•
Keep the air conditioner free of any obstructions such as
drapes, curtains, blinds, etc.
•
The exhaust hose should be free of any obstructions.
•
Do not place the air conditioner on an unstable or raised
surface because it could fall and cause damage or injury.
•
Do not place the air conditioner in direct sunlight or near
a heat source such as baseboard heaters, stoves, etc.
•
The window panel can be installed in a window with a
minimum 51 cm
to a maximum 101.6 cm
opening.
(51 cm)
(51 cm)
ELECTRICAL REQUIREMENTS
POWER SUPPLY CORD
Wiring Requirements
•
220 Volt, 50Hz, 16-amp fused grounded outlet
•
The use of a time-delay fuse or time-delay circuit breaker
is recommended.
•
Use a dedicated circuit only.
NOTE:
Do not operate any other electrical
appliances on this circuit or you may trip the circuit
breaker/fuse.
If this power supply cord is damaged, it cannot be repaired. It
must be replaced with a cord from the product manufacturer.
4
ENGLISH
WARNING
Electrical Shock Hazard
Plug into a grounded outlet
only
.
Do not remove the ground
contacts
from the power
cord plug.
Do not use an adapter.
Do not use an extension cord.
Ïäìïøõè÷
o follow
these instructions can result in death,
fire
òõèïèæ÷õìæäï
shock.