Verification Checklist:

1

Tank location: 
- Is 

room size less than 10x10x7 (700 cu. ft.)? If yes, Louvered door or similar ventilation is needed. 

- Back of unit 

away from wall by 7 inches. 

Front of unit is free and clear.  

- Is the water heater

 level? If no, add shims under the base of the unit.

2

Plumbing connections: 
- Do not prevent 

air filter removal. 

- No leaks after 

filling the tank with water, either when water is flowing or not.

3

Condensate lines are in place:  
- Longer PVC pipe on lower drain nozzle and directed into a floor drain or a condensate pump.

4

T & P valve is working and drain line completed per local code.

5

Electrical connection does not prevent air filter removal.

6

Verify 

control panel displays 120°F (49°C) Hybrid Mode.

7

Verify 

filter is in place.

Normal startup—what to expect after pressing the POWER button

Elapsed time

Hybrid water heater actions

Comments

:00 to 2:00 minutes

Unit will go through self-check

This 2 minute off-time prevents compressor from being “short cycled”  
(improved reliability).

2:00 to 10:00 minutes

Compressor and fan turn on and run for 8 minutes

This 8 minute period is used to ensure tank is full of water (dry fire prevention algorithm).

10:00 to 30:00 minutes Compressor and fan turn off, heating   elements turn on for approximately 

20 minutes.

Quickly provides initial amount of hot water for user (~25 gallons).

30 minutes and beyond Upper element turns off, and compressor turns back on.

Uses efficient heat pump for majority of heating.

NOTE: Heat pump operating range is 45°F to 120°F.

Summary of Contents for GeoSpring GEH50DEEDSC

Page 1: ...heater Power Requirements Check the markings on the rating plate of the water heater to be certain the power supply corresponds to the water heater requirements Location Locate the water heater in a clean dry area as near as practical to the area of greatest heated water demand Long uninsulated hot water lines can waste energy and water Note Because this unit draws in air from the room to heat the...

Page 2: ...r before fitting the adapter to the cold water connections on heater Any heat applied to the hot or cold water connection will permanently damage the dip tube Dimensions and Installation Information in inches Front back clearance requirements A 7 clearance is recommended with a minimum of 5 1 2 air space between any object and the front and back of the water heater and 7 on each side Clearance is ...

Page 3: ... 4 T P valve is working and drain line completed per local code 5 Electrical connection does not prevent air filter removal 6 Verify control panel displays 120 F 49 C Hybrid Mode 7 Verify filter is in place Normal startup what to expect after pressing the POWER button Elapsed time Hybrid water heater actions Comments 00 to 2 00 minutes Unit will go through self check This 2 minute off time prevent...

Page 4: ...0 gallon standard electric water heater with 65 gallons first hour rating Installs like a standard electric water heater with the same water and electrical connections Limited 10 year warranty provides peace of mind and dependability ENERGY STAR qualified exceeds federal guidelines for energy efficiency and provides year round energy and money savings Offers remote functionality to control modes a...

Reviews: