Water Supply Connections: Refer to the illustration below for suggested 
typical installation. The installation of unions or flexible copper connectors 
is recommended on the hot and cold water connections so that the water 
heater may be easily disconnected for servicing if necessary. The HOT and 
COLD water connections are clearly marked and are 3/4” NPT on all models.

Note: Install a shut-off valve in the cold water line near the water heater. 
This will enable easier service or maintenance of the unit later.

IMPORTANT: Do not apply heat to the HOT or COLD water connections. 
If sweat connections are used, sweat tubing to adapter before fitting the 
adapter to the cold water connections on heater. Any heat applied to the 
hot or cold water connection will permanently damage the dip tube.

Dimensions and Installation Information (in inches) 

Front & back clearance requirements: A 7” clearance is 
recommended with a minimum of 5-1/2” air space between any 
object and the front and back of the water heater and 7” on each 
side. Clearance is needed to allow for removal of the front and back 
covers in the event service is needed.

Condensate drain required: A primary 
drain pipe must be installed at the top right 
side of the water heater. The primary drain 
is intended to carry all condensate away.

Top filter removal clearance 

requirements: A minimum 6” clearance is 
required at the top of the water heater to 
pull the filter up and remove it for cleaning. 
It is critical that the hot and cold water 
plumbing and the electrical connections do 
not interfere with the removal of the filter.

Above illustration intended for dimensional reference only.
Refer to photograph for actual product appearance.

Summary of Contents for GeoSpring GEH50DEEDSC

Page 1: ...heater Power Requirements Check the markings on the rating plate of the water heater to be certain the power supply corresponds to the water heater requirements Location Locate the water heater in a clean dry area as near as practical to the area of greatest heated water demand Long uninsulated hot water lines can waste energy and water Note Because this unit draws in air from the room to heat the...

Page 2: ...r before fitting the adapter to the cold water connections on heater Any heat applied to the hot or cold water connection will permanently damage the dip tube Dimensions and Installation Information in inches Front back clearance requirements A 7 clearance is recommended with a minimum of 5 1 2 air space between any object and the front and back of the water heater and 7 on each side Clearance is ...

Page 3: ... 4 T P valve is working and drain line completed per local code 5 Electrical connection does not prevent air filter removal 6 Verify control panel displays 120 F 49 C Hybrid Mode 7 Verify filter is in place Normal startup what to expect after pressing the POWER button Elapsed time Hybrid water heater actions Comments 00 to 2 00 minutes Unit will go through self check This 2 minute off time prevent...

Page 4: ...0 gallon standard electric water heater with 65 gallons first hour rating Installs like a standard electric water heater with the same water and electrical connections Limited 10 year warranty provides peace of mind and dependability ENERGY STAR qualified exceeds federal guidelines for energy efficiency and provides year round energy and money savings Offers remote functionality to control modes a...

Reviews: