background image

To power 

supply 

Red (+)

Black or blue (-)

Red Stripe (+)

Cap wires

Connect LED strips using in-line (IDC) connectors 

or twist-on wire connectors.
NOTE: 

Seal the connectors with silicone.

Must cap all exposed wires with appropriate wire 

connectors.
NOTE: 

Seal the connectors with silicone.

Run a wire from the Power Supply to each 

channel letter and connect to the first LED 

module on the strip. 
Must be used with Tetra

®

 24 Volt Power Supplies.

1

2

3

Connect the red stripe wire (+) of the LED strip to 

the red wire (+) of the power supply.  Connect the 

white wire (-) of the LED strip to the black or blue 

wire (-) of the power supply.
NOTE:

  All electrical connections should be made 

within the letter. Seal the connectors with silicone.

4

Power 

Supply

To Tetra LED System

Red (+)

Black or blue (-)

Red stripe (+)

White (-)

Electrical Connections

Retrofit Instructions

1.   (Existing Signs Only) Prior to installation, survey the site for information regarding power and accessibility inside and outside the building.  Ensure   

 

that the branch circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED power supply, and have  

 

 

a current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes (whichever is less).   

2.   (Existing Signs Only) Remove the existing lighting equipment to be replaced, such as neon tubing or fluorescent tubes; and associated    

 

 

transformers and ballasts. Care should be taken not to break the existing neon or fluorescent tubes.  

 NOTE:

 Follow all federal and local regulations when disposing of neon tubing, fluorescent tubes, transformers and ballasts.

3.   (Existing Signs Only)  If removal of the existing lighting equipment eliminates the disconnect switch, as required by applicable local, state, or  

 

 

country electrical codes; a new disconnect switch must be installed.

4.   (Existing Signs Only) Make sure the removal of lighting equipment does not compromise the integrity of the sign body (i.e. water intrusion). Fill in    

 

all holes 0.5 in. (13 mm) or smaller with the appropriate amount of rated caulk or sealant. For holes greater than 0.5 in. (13 mm), use an aluminum   

 

or zinc coated steel patch with rivets and sealant.

5.   (Existing Signs Only) A clean and dry mounting surface ensures optimum adhesion if the self-adhesive method of mounting is chosen.  Follow  

 

 

the manufacturer’s directions when using a non-oil based solvent, such as rubbing alcohol to clean the surface area where you intend to mount    

 

the module.  Before installing, ensure the surface is dry.

6.   Using the layout guidelines above, determine required number of LED modules required to illuminate the sign.
7.   A Tetra

®

 24VDC Class 2 Power Supply, as listed below, must be used with this retrofit kit. Using the Maximum Loading chart below, determine the    

 

number of Tetra

®

 Class 2 Power Supplies required to power the number of LED modules required to illuminate the sign, so as not to overload  

 

 

the Tetra

®

 Class 2 Power Supply chosen.

8.   Follow the instructions above to properly mount the LED modules. 
9.   Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above.
10. Connect the power unit to the supply in accordance with the applicable local, state, and country electrical codes, and the instructions found in the  

 

power supply installation guide.

11. If required, the disconnect switch shall be installed by qualified personnel, in accordance with applicable  local, state, and country electrical codes.

White (-)

Seal connectors 

with silicone

Seal connectors 

with silicone

Seal connectors 

with silicone

Summary of Contents for GEMX2471-W1

Page 1: ...omply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interf...

Page 2: ...roved 22 14 AWG 0 33 2 08 mm2 wire connectors or 22 18 AWG 0 33 0 82 mm2 in line IDC connectors 6 or 8 M3 or M4 screws 1 8 inch 3 2 mm rivets or electronic grade silicone or equivalent Tetra 24 Volt Power Supply Tetra MAX LED modules Components Layout Modules 2 3 4 5 1 Drill a 1 4 inch 6 4 mm hole near the LED strip and grommet the hole for supply wire access 5 6 Clean and remove all debris from t...

Page 3: ... eliminates the disconnect switch as required by applicable local state or country electrical codes a new disconnect switch must be installed 4 Existing Signs Only Make sure the removal of lighting equipment does not compromise the integrity of the sign body i e water intrusion Fill in all holes 0 5 in 13 mm or smaller with the appropriate amount of rated caulk or sealant For holes greater than 0 ...

Page 4: ...to ensure uniformity of illumination on the face of the letter This product is intended solely for the use of non residential signage lighting and is not intended for use in any other applications Conforms to the following standards IP66 rated www gelighting com GE and the GE Monogram are trademarks of the General Electric Company All other trademarks are the property of their respective owners In...