06 Electrical Connection
User Manual
V1.0-2023-10-30
No�
Port Definition
Function
Description
1
DO1+
Dry contact
Optionnal function. The inverter reserves a
dry contact controlling port, which supports
connecting additional
contactors to enable/disable the load. For high
voltage AC230V. PIN2 is reserved for safety
regulations.
2
NC
Reserved PIN
3
DO1-
Dry contact
4
GND
Power supply
Optionnal function. Supplies power for external
devices.
5
12V_S
6
RSD_12V
Controls the RSD
modules externally.
Reserved. Connects to RSD_12V and 12V_S to
control the RSD module rapidly.
7
GND
Remote shutdown
Optionnal function. Controls the equipment on/
off remotely.
8
Remote shutdown
9
DO2+
Dry contact
Optionnal function. The inverter reserves a
dry contact controlling port, which supports
connecting additional contactors to enable/
disable the load.
10
DO2-
11
COM/DRM0 or
REF_1
DRED or RCR
Optionnal function.
• DRED (Demand Response Enabling
Device): the inverter satisfies the Australian
DERD certification and offers DRED signal
controlling ports.
• RCR (Ripple Control Receiver): In Germany
and some other European regions, grid
companies use Ripple Control Receiver
to convert grid dispatching signals into dry
contact mode for transferring. And the power
station receives grid dispatching signals
through dry contact communication mode.
12
REFGEN or
REF_2
13
DRM4/8 or DI_4
14
DRM3/7 or DI_3
15
DRM2/6 or DI_2
16
DRM1/5 or DI_1
17
EMS/PAR
EMS communication
or parallel
connection port
•
Optionnal function. EMS communication port:
connects with the third party device. The third
party device is not supported in a parallel
system.
•
Optionnal function. PAR communication port:
serves as the communication port for the
inverter parallelizing as shown below.
PAR
PAR