Table 1: Loop Resistance per 1000 feet 

Wire Type 

Resistance 

24 AWG /0,53 mm 

52 ohms 

23 AWG /0,57 mm 

42 ohms 

22 AWG /0,64 mm 

33 ohms 

 

Table 2: Power Distance Chart 

Power Supply Voltage 

12 VDC 

24 VAC 

28 VAC 

Voltage at the Camera 

10.8 VDC 

21.6 VAC 

21.6 VAC 

Dual 24 AWG 

448 ft. / 137 m 

896 ft. / 273 m 

2,388 ft. / 728 m 

100 mA Camera 

Dual 23 AWG 

564 ft. / 172 m  1,130 ft. / 345 m 

3,012 ft. / 918 m 

Dual 24 AWG 

150 ft. / 46

 

m 300 

ft. 

92

 

796 ft. / 243 m 

300 mA Camera 

Dual 23 AWG 

190 ft. / 58 m 

378 ft. / 115 m 

1,004 ft. / 306 m 

Dual 24 AWG 

46 ft. / 14 m 

90 ft. / 28 m 

240 ft. / 73 m 

1 AMP Camera 

Dual 23 AWG 

58 ft. / 18 m 

114 ft. / 35 m 

300 ft. / 92 m 

 

Important Safety Warnings 

•  Installation should be made by a qualified service person and should 

conform to all local codes. 

•  DO NOT bundle UTP signals in the same conduit as high-voltage wiring. 

•  To reduce the risk of fire or electrical shock, do not expose these products to 

rain, moisture, dripping or splashing. 

•  No objects filled with liquids, such as vases, shall be placed on GE equipment.  

•  DO NOT block ventilation openings to let sufficient airflow to the UTP devices. 

•  Only unplugging the power cord is considered as a main power disconnect. 

•  DO NOT connect multiple outputs together. 

•  Make sure that the mains Voltage input is set to the proper local voltage. 

 

Summary of Contents for GEC-4VPHUB

Page 1: ...esk or rack mounted They use Category 2 7 twisted pair wires and do not require power They provide built in surge suppression to protect video equipment against damaging voltage spikes and provide noi...

Page 2: ...s been damaged in any way such as a power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not o...

Page 3: ...vers Passive GE transceivers can transmit video and Up the Coax P T Z control signals up to 750 ft 228 m We recommend using short 18 AWG solid wires for ground connections GE VPD products follow the E...

Page 4: ...ft 14 m 90 ft 28 m 240 ft 73 m 1 AMP Camera Dual 23 AWG 58 ft 18 m 114 ft 35 m 300 ft 92 m Important Safety Warnings Installation should be made by a qualified service person and should conform to all...

Page 5: ...nect to the transceiver hub Make sure that the same UTP pair and polarity are used on both the transmit and receive sides Video Connect the baseband Video signal output of the camera to the BNC of the...

Page 6: ...connector to a qualified earth ground using a short thick wire If the picture is scrambled change the polarity of the twisted pair wires on the corresponding terminal block Technical Specifications E...

Page 7: ...16VPHUB 17 x 1 74 x 3 in 43 x 4 2 x 7 6 cm GEC 32VPHUB 17 x 1 74 x 3 in 43 x 4 2 x 7 6 cm Weight GEC 4VPHUB 0 2 lb 90 g GEC 8VPHUB 3 3 lb 1500 g GEC 16VPHUB 3 3 lb 1500 g GEC 32VPHUB 3 3 lb 1500 g Env...

Page 8: ...9 P N 1069682 REV 1 0 ISS 14APR10 EIA TIA 568A B Color Codes Midspan Control Room Data Connections GEC 4VPHUB Cameras 1 4 GEC 8VPHUB GEC 16VPHUB GEC 32VPHUB Cameras 1 8 GEC 16VPHUB GEC 32VPHUB Cameras...

Page 9: ...interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on...

Reviews: