2. Refrigerator Compartment Control
1) Adjust by the pushing the REF.SET button.
LOW - MEDIUM LOW - MEDIUM - MEDIUM MAX - MAX
2) Refrigerator Fan controlled by each mode ON/OFF point.
3) Refrigerator Compartment ON/OFF Difference : 0.5C
- MEDIUM OFF point : 5.2C
- When Room Temperature (RT) is below 13C, Refrigerator sensor OFF point 2C up ( so, MEDIUM OFF : 7.2C )
4) Weak Cooling Prevention Function
- This funtion is free of Freezer sensor.
- When refrigerator compartment reaches the Fan OFF point, the Fan is OFF.
and then Compressor controlled by Freezer sensor.
- Weak cooling temperautre is + 7C in each sensor OFF temperature.
- Weak cooling terminate temperautre is same as each sensor OFF temperature.
6) Control Temperature Point in Each Mode
7) SUPER REF. (QUICK) Mode : This mode runs for 40 minutes.
- Until the sensor reaches the Excess Refrigeration OFF point ( -7C), Refrigerator Fan and compressor is ON.
- Until the QUICK Mode ends, the appliance runs with MAX dial mode.
- After QUICK Mode ( about 40 mins ) the normal mode start.
FUNCTIONS ( TEMPERATURE CONTROL_Dispenser Model )
Freezer
Sensor
Excess
Refrigeration
OFF point
ON/OFF
MAX MODE
NORMAL MODE
Start
QUICK MODE (40MIN )
Initially On
1st Press
2nd Press
3rd Press
4th Press
5th Press
6th Press
Sensor On
5.7
4.7
3.7
9.7
8.7
7.7
6.7
Sensor Off
5.2
4.2
3.2
9.2
8.2
7.2
6.2
Sensor On
7.7
6.7
5.7
11.7
10.7
9.7
8.7
Sensor Off
7.2
6.2
5.2
11.2
10.2
9.2
8.2
Sensor On
12.2
11.2
10.2
16.2
15.2
14.2
13.2
Sensor Off
5.2
4.2
3.2
9.2
8.2
7.2
6.2
Sensor On
14.2
13.2
12.2
18.2
17.2
16.2
15.2
Sensor Off
7.2
6.2
5.2
11.2
10.2
9.2
8.2
Medium Min
7
6
5
8
Medium Max
Max
Min
Normal
Weak refrigeration
RT <= 13C
Weak refrigeration
& RT <= 13C
Division
Display
Temperature
4
Medium
3
2
10
Summary of Contents for GCG200NGWC
Page 1: ...Pub No DWWR1053E GC 200YAWC GC 200YHWC GC 200NGWC GC 200NHWC ...
Page 3: ...2 External Size Features are model dependent All model has same size SPECIFICATIONS 2 ...
Page 27: ...1 Basic Model 2 Dispenser Model WIRING DIAGRAM 26 ...
Page 51: ...COOLING CYCLE HEAVY REPAIR Brzing Reference Drawings 50 ...