LCD
GRAPHIC
FACTORY
FUNCTION
DISPLAY
SETTING
DESCRIPTION
SETTING
6-33
* 85
RESET INT
RESET INTERVAL
5
Time interval between reset attempts as set
in Function Code 84.
2 TO 20
Time in seconds.
MOTOR CHARACTERISTICS
86
MOTOR CAP
MOTOR Hp CAPACITY
1
This Function Code is used to select the
motor Hp capacity in relation to the
drive Hp capacity.
0:
One frame up in Hp capacity (variable torque
application).
1:
Standard capacity (constant torque application).
2:
One frame down in Hp capacity.
3:
Two frames down in Hp capacity.
87
MOTOR 1-Ir 0.00 TO
MOTOR #1 NAMEPLATE FULL LOAD CURRENT
RATED
2000
AMPS
88
MOTOR 1-Io 0.00 TO
MOTOR #1 NO LOAD CURRENT (Magnitizing
2000
current).
89
MOTOR 2-Ir 0.00 TO
MOTOR #2 NAMEPLATE FULL LOAD CURRENT
RATED
2000
AMPS
90
TUNING
MOTOR TUNING
0
This Function Code is used to tune the
primary resistance and inductance of the
motor.
0:
Inactive
1:
Active
WARNING:
Ensure the motor is connected, free to rotate and at a standstill. Upon setting
Function Code 90 equal to 1, the drive will pulse the motor three (3) times in order to calculate
the settings in Function Codes 91 and 92.
CAUTION:
When using motor tuning, be sure the correct values are set in Function Code 03, 04 and 87.