FTP-1000
Installation Manual
6
Testing
Use the following procedures to test the touchpad for display function, button function, and system operation.
Test touchpad display function
Press and hold the
4
,
5
, and
6
buttons together for about three seconds, then release them.
The touchpad cycles though all text messages, then returns to the time display.
Test button function
To test the button functions, do the following:
1. Press and hold the
7
,
8
, and
9
buttons together for about three seconds, then release them. The display
should go blank.
2. Press each touchpad button to display a different string of letters or numbers for each button. For
example,
11111111111, AAAAAAAAAAA
, etc. Pressing
*
displays Es and pressing
#
displays Fs. After
about 15 seconds of no touchpad activity, the touchpad returns to the time display.
Test system operation
Testing the system operation requires you to perform some standard operations to ensure that they work
properly.
To test the system’s operation, do the following:
Arm/disarm the system, activate the touchpad panics, bypass sensors, and turn chime on/off to verify correct
operation.
Note:
You must enable the touchpad panic buttons in order to activate them. Please see the panel installation instructions for
more information.
Refer to the panel’s user manual for complete system operating instructions and user programming procedures.
CAUTION:
Contact the central monitoring station before activating alarms, to avoid dispatching local police and fire
departments