EVT-Pro Pump Case with Electronics
Click here to go to Electrical Drawing
Rev - 1.0 / Page 23 / 10/10/2012
Bi-directional Pump
Restriction adjust
Softcase Removed for Clarity
Oil Fill / ISO46 or
AW46.
Pump Battery
Pump Serial
Number
USB connection to
Laptop
Pump Adjustment -
NEVER adjust this! It
is set and sealed by
the manufacturer
Pump Restriction Adjustment
EVT-Pump Bleeding Procedure:
To clear an air bubble in the cable or pump, simply connect the hydraulic
ends of the cable, open the reservoir vent cap and pump the hand pump
until the air bubble clears. Close the reservoir vent cap when complete.
NOTE: With all the cylinders retracted,
oil fill level should be at the top of the
reservoir or the bottom of the fill spout.