Nut Plate

Adapter Block

3/8-16 Washer and Bolts

Torque Bolts to 25 - 32ft-lbs.

(34-43 N-m)

ADAPTER PLATE FOR

SQUARE POLE

FIGURE 6

DRILLING TEMPLATE

SQUARE POLE MOUNTING

.312 in. DIA.

(8 mm DIA.)

5.250 in.

(133 mm)

(MIN.) 1.812 in.

(46 mm)

1.250 in. DIA.

(32 mm DIA.)

(HOLE)

.656 in. (17 mm)

1.312 in. (33 mm)

2.196 in.

(56 mm) 4.392 in.

(112 mm)

.438 in. DIA.

(11 mm DIA.)

(2 PLACES)

FIGURE 5

FIXTURE ARM TO ARM ADAPTER

Torque Top Bolt

to 25 - 32 ft-lbs.

(34-43 N-m)

Torque Bottom Bolt

to 25 - 32 ft-lbs.

(34-43 N-m)

FIGURE 7

 

NOTE:

 Make all electrical connections in accordance  

  with the National  Electrical Code and any applicable   

  local code requirements.  

  Strain relief for incoming power must be  provided in  

  the pole top by the customer.

  Supply Wire Type and Size, for Customer Connection  

  to Terminal Board: 16 AWG (1.5mm

2

) to 6 AWG  

  (10mm

2

) Solid or Stranded.

WIRING

4

CAUTION

Risk of Damage or Injury:

  Door should be closed with 

screw until fixture in final location.

Terminal Board Connections:

Terminal Board Position 

Supply Type

 

L1 

High Line

 

Ground

 

N/L2 

Low Line/Neutral

 

NOTE:

 Verify that supply voltage is correct by   

  comparing it to nameplate inside door or on carton.

3c   Square Pole Architectural Arm Mounting

This luminaire has been configured the same as 3b 

and an adapter plate has been included to mount to 

a square pole.  Hole pattern on square pole shall be in 

 accordance with 

Figure 5

.

  Orient adapter block so that the end marked top is in  

  the up  position.

  With adapter block end oriented properly, mount  

  adapter block to pole with the nut plate and 3/8-16  

  bolts and washer supplied as shown.  Torque  3/8-16  

  bolts to 25 - 32ft-lbs (34-43 N-m).  (See 

Figure 6

)

•  Place fixture against adapter block.

  In top location install  3/8-16 bolt through lock   

  washer, washer and mounting arm as shown.  

  (See 

Figure 7

)

  Open arm door and Install 3/8 bolt into tapped hole  

  of adapter block.  (See 

Figure 7

)

  Torque top and bottom bolts to 25 - 32 ft-lbs (34-43 N-m).

•  Inspect installation to ensure fixture is secure.

Dimming Input/Output
Control Voltage

1

 

Low (0V)  High(7.5-10V)

Nominal Input Wattage

2

 

20% of Max 

100%

Nominal Lumen Output

2

External Dimming Control (If Applicable):

  Gray Lead  = 0VDC (-)  

  Violet Lead = Up To 10VDC (+)

 

1

 Linear Transition between Low and High

 

2

 Component and system tolerance may affect the  

    end point levels and linearity of transition

Summary of Contents for Evolve EAMM

Page 1: ... undesired operation This Class A RFLD complies with the Canadian standard ICES 003 Ce DEFR de la classe A est conforme à la NMB 003 du Canada Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated ...

Page 2: ... Torque top and bottom bolts to 25 32 ft lbs 34 43 N m Inspect installation to ensure fixture is secure MOUNTING 3 Follow the appropriate installation instructions based on your selected mounting method a Slipfitter Mounting b Round Pole Architectural Arm Mounting c Square Pole Architectural Arm Mounting 3a Slipfitter Mounting This luminaire has been configured specifically to mount to a 2 inch pi...

Page 3: ...that supply voltage is correct by comparing it to nameplate inside door or on carton 3c Square Pole Architectural Arm Mounting This luminaire has been configured the same as 3b and an adapter plate has been included to mount to a square pole Hole pattern on square pole shall be in accordance with Figure 5 Orient adapter block so that the end marked top is in the up position With adapter block end ...

Page 4: ...through the included PE Receptacle Refer to instructions included with GE Dimming PE Control regarding appropriate settings for dimming control CAUTION Ensure the PE socket base gasket is properly seated in the die casting hole before tightening the holding screws SLIPFITTER MOUNTING Connect Luminaire wire leads to supply wire Connections are to be made in interior of pole Replace pole cap A wirin...

Page 5: ...pouvant causer un fonctionnement indésirable Ce DEFR de la classe A est conforme à la NMB 003 du Canada Remarque Cet appareil a été testé et reconnu conforme aux limites établies pour les appareils numériques de classe A selon la partie 15 des règles de la FCC Ces limites sont conçues pour assurer une protection raisonnable contre les interférences nuisibles dans un environnement commercial Cet ap...

Page 6: ...rer les vis supérieures et inférieures à 25 32 ft lbs 34 43 N m Inspecter pour s assurer que l installation est sûre MOUNTING 3 Choisir les instructions adaptées à la méthode d installation a Installation par encastrement b Installation par support sur poteau à section circulaire c Installation par support sur poteau à section carrée 3a Installation par encastrement Ce lampadaire a été configuré s...

Page 7: ...sur le carton 3c Installation par support sur poteau à section carrée Ce lampadaire a été configuré de la même manière que 3b et une plaque intermédiaire a été incluse pour installation sur poteau à section carrée L arrangement des trous de fixation sur poteau à section carrée doit être conforme à la Figure 5 Orienter le bloc intermédiaire tel que l extrémité identifiée par l inscription haut est ...

Page 8: ...on de nettoyage en utilisant un chiffon doux Rincez avec de l eau froide et propre puis essuyez AVERTISSEMENT Risque de choc électrique Avant de commencer toute opération d entretien assurez vous que l alimentation élec trique est coupée MONTAGE SUR JOINT COULISSANT Connectez les fils conducteurs du luminaire au câble d alimentation Les connexions doivent être faites à l intérieur du poteau Réinst...

Page 9: ...producto PRECAUCIÓN Riesgo de lesiones Utilice gafas de seguridad y guantes durante la instalación y mantenimiento ADVERTENCIA Riesgo de lesiones o daño La unidad fallará si no se instala apro piadamente Siga las instrucciones de instalación Este dispositivo cumple con la Parte 15 de las Reglas de la FCC La operación está sujeta a las dos condiciones siguientes 1 este dispositivo no puede causar i...

Page 10: ...e con brazo arquitectónico en poste redondo c Montaje con brazo arquitectónico en poste cuadrado 3a Montaje con ajustador deslizante Esta lámpara ha sido configurada específicamente para montaje en abrazaderas para tubo de 2 pulgadas 2 3 8 de Diámetro Exterior Sostenga la lámpara aproximadamente a nivel con el tubo Hale los alambres a través del brazo y coloque el ajustador deslizante sobre el tub...

Page 11: ... del montaje 3b y se incluye una placa adaptadora para montaje en poste cuadrado El patrón de orificios en el poste cuadrado deberá estar de acu erdo con la Figura 5 Oriente la placa adaptadora de modo que la parte superior marcada como extremo end esté en la posición arriba Con el extremo de la placa adaptadora orientada apropia damente monte la placa adaptadora al poste con la tuerca tipo placa ...

Page 12: ...s tornillos de fijación y gire el receptáculo hasta dirigir Norte hacia el norte verdadero con la mayor aproximación posible Apriete los tornillos de fijación e instale el control PRECAUCIÓN Asegúrese de que la junta de la base del zócalo PE esté cor rectamente asentada en el agujero de la pieza fundida antes de apretar los tornillos de fijación MONTAJE CON POSICIONADOR DESLIZANTE Conecte los cabl...

Reviews: