– 9 –
Specification for 15, 16 Cu Ft Energy Star
Refrigerator
DISCONNECT POWER CORD BEFORE SERVICING
IMPORTANT - RECONNECT ALL GROUNDING
DEVICES
DISCONNECT POWER CORD BEFORE SERVICING
IMPORTANT - RECONNECT ALL GROUNDING DEVICES
All parts of this appliance capable of conducting
electrical current are grounded. If grounding wires,
screws, straps, clips, nuts or washers used to
complete a path to ground are removed for service,
they
must
be returned to their original position and
properly fastened.
IMPORTANT SAFETY NOTICE
This information is intended for use by individuals
possessing adequate backgrounds of electrical,
electronic and mechanical experience. Any attempt
to repair a major appliance may result in personal
injury and property damage. The manufacturer or
seller cannot be responsible for the interpretation of
this information, nor can it assume any.
ELECTRICAL SPECIFICATIONS
Cold Control (Position 5)
28.0°F
Defrost Control @ 120
VAC ~60Hz
Adaptive Defrost
Defrost Thermostat
64-23°F
Electrical Rating:
120 VAC AC 60Hz
Maximum Current
Leakage
0.75 mA
Maximum Ground Path
Resistance
0.14 Ohms
NO LOAD PERFORMANCE
Control Position 5/C and Ambient
Temperature of
70°F
90°F
Fresh Food, °F / °C
33-39 33-41
Frozen Food, °F / °C
(-4) -2 (-4) -4)
Run Time %
23-33 37-49
REFRIGERATION SYSTEM
Refrigerant Charge
(R134a)
4.5 oz
Compressor @ 120 VAC
~60Hz
615 BTU/hr. /180W
Minimum Vacuum @ 2
minutes
19 inches / 48 cm
Minimum Equalized Pressure
@70°F / 21°C
37.8 PSIG / 362 kPa
@90°F / 32°C
50.7 PSIG / 451 kPa
INSTALLATION
Clearance must be provided for air circulation
TOP
1 inch / 25 mm
SIDES
3/4 inch / 19 mm
REAR
2 inch / 51 mm
REPLACEMENT PARTS
Temperature Control
WR09X21006
Electronic Defrost
Control Board (EDC)
WR55X21128
Defrost Thermostat
WR50X10071
Defrost Heater
WR09X21107
Condenser Fan Motor
WR60X20871
Evaporator Fan Motor
WR60X10346
Relay/Overload
WR07X10133
Drier
WR86X0096
Fuse Harness
WR55X21096
Pub. No. 31-51874-5