– 23 –
Cold Control Removal
1.
Remove the control console (see the
Control
Panel Removal
section in this Guide).
2. Remove the temperature adjustment knob.
3.
Disconnect the wire leads and ground wire from
the Cold Control.
4. Push Cold Control either to the left or right to
clear the retaining tabs. Lift up on the side that
has cleared from the tab and remove.
5.
Remove (do not discard) the EPS Duct transition
to access the Cold Control capillary.
6. Remove the capillary from the sleeve.
NOTE
: When reinstalling the Cold Control, reconnect
the ground wire and fully insert the Cold Control
capillary into the sleeve.
The Cold Control switches 120 VAC from the
brown
wire to the
grey
to the Defrost Control.
120 VAC is supplied to the Cold Control from L1 to
CC terminal when the K2 relay, located on the EDC
board, is in the compressor run position.
On electromechanical models, the Cold Control
switches 120 VAC from the
brown
wire to the
gray
to the Defrost Control.
On models with an EDC board, 120 VAC is supplied
to the L1 terminal of the EDC. When the K2 relay is
closed, 120 VAC is supplied to the cold control.