dpsb619Gdww – GE profile

 super 7.0 Cu. Ft. Capacity Gas dryer with stainless steel drum 

For complete information, see installation instructions packed with your dryer.

ducting Materials: 

For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If “all 

rigid metal” duct cannot be used, then “flexible all metal” venting can be used, but it will reduce the 

maximum recommended duct length.

Exhaust Length Calculation: 

1.  Determine the number of 90° turns needed for your installation. If you exhaust to the side or  

bottom of dryer, add one turn.

2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown  

  in the table. The maximum length for flexible ducts are less than for rigid duct.

 A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 

90° elbow. A turn over 45° should be treated as a 90° elbow.

Exhausting the dryer to the outside is strongly recommended 

to prevent large amounts of 

moisture and lint from being blown into the room. Gas dryers or any dryer located in a closet must be 

exhausted to the outside.

Caution: 

For personal safety do not terminate exhaust into a chimney, under any enclosed house 

floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture 

could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen 

exhaust, since the combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. 

The wall cap must also be located at least 12" above the ground or any other obstruction with the 

opening pointed down.
Other terminations, such as louvered wall boxes, are acceptable provided they are equivalent to a  

4" opening dampered wall cap.

For  more information on venting kits and accessories, please call 1-800-GE-CAREs.

dryer Exhausting Information – Use Metal duct Only 

Vertical and Horizontal ducting

 

 

150 ft. 

127 ft. 

75 ft. 

52 ft.

 

 

140 ft. 

117 ft. 

65 ft. 

42 ft.

 

 

130 ft. 

107 ft. 

55 ft. 

32 ft.

7.3 Capacity Electric  

120 ft. 

97 ft. 

45 ft. 

22 ft.

and Gas Dryers 

110 ft. 

87 ft. 

35 ft. 

12 ft.

 

 

90 ft. 

60 ft. 

55 ft. 

45 ft.

 

 

60 ft. 

45 ft. 

40 ft. 

30 ft.

7.0 and 6.0   

45 ft. 

35 ft. 

30 ft. 

20 ft.

Capacity Models  

35 ft. 

25 ft. 

20 ft. 

15 ft.

all Electric Dryers 

25 ft. 

15 ft. 

15 ft. 

10 ft.

 

 

90 ft. 

60 ft. 

55 ft. 

45 ft.

7.0 and 6.0   

60 ft. 

45 ft. 

40 ft. 

30 ft.

Capacity Models  

45 ft. 

35 ft. 

30 ft. 

20 ft.

all Gas Dryers 

35 ft. 

25 ft. 

20 ft. 

15 ft.

 

 

60 ft. 

48 ft. 

30 ft. 

18 ft.

 

 

52 ft. 

40 ft. 

22 ft. 

14 ft.

 

 

44 ft. 

32 ft. 

14 ft. 

10 ft.

5.7 Capacity Electric  

32 ft. 

24 ft. 

— 

and Gas Dryers 

28 ft. 

16 ft. 

— 

Number

of

90°

Turns

Maximum Length of 4"

Dia.

 Rigid Metal

 Duct 

Maximum Length of 4"

Dia. 

Flexible Metal

 Duct 

Exhaust Hood Type

Exhaust Hood Type

Domestic  

Dryer Models

A

4" Opening

B

2-1/2"

 

Opening

A

4" Opening

B

2-1/2"

 

Opening

Best Performance

A

B

2-1/2

4

GE Dryer Vent

A

B

2-1/2

4

GE Dryer Vent

A

special Installation Requirements

Alcove or Closet Installation: 

• If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back. 

• The dryer MUST be exhausted to the outside. 

•  Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 

                0" either side 

                3" front and rear

• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”. 

•  Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of 

open area equally distributed. If this closet contains both a washer and a dryer, doors must contain  

a minimum of 120 sq. in. of open area equally distributed.

• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.

bathroom or bedroom Installation:

• The dryer MUST be exhausted to the outdoors. 

•  The installation must conform with the local codes, or in the absence of local codes, with the  

National Fuel Gas Code, ANSI Z223.

Minimum Clearances other than Alcove or Closet Installation:

•  Minimum clearances to combustible surfaces 

                0" both sides 

                3" rear

For answers to your Monogram,

®

 GE Profile

 or  

GE

®

 appliance questions, visit our website at

GEAppliances.com or call 

GE Answer Center

®

 service, 800.626.2000.

Listed by 

Underwriters 

Laboratories

specification Revised 4/06

270187