Installation Instructions
27
For 3-wire Connection ONLY:
Be sure the dryer’s green ground wire
is connected to green ground screw on
cabinet rear.
D
For 4-wire Connection ONLY:
Remove the dryer’s ground wire from
behind the green ground screw and
connect it to the center screw of the
terminal block.
Attach ground wire of power cord to the
cabinet with the green ground screw.
CONNECTING DRYER POWER
CORD (cont.)
For 3-wire and 4-wire Connection:
Connect the neutral (center line on 3-wire,
white line on 4-wire) line to the center of
terminal block.
E
For 3-wire and 4-wire Connection: Tighten
all terminal block screws completely.
CONNECTING DRYER POWER
CORD (cont.)
For 3-wire and 4-wire Connection:
Reinstall the terminal block access cover.
IMPORTANT:
Do not leave the access
cover off.
F
G
Ground
Wire
(3-Wire Connection Shown)
(4-Wire Connection Shown)
(3-Wire Connection Shown)
(3-Wire Connection Shown)
(3-Wire Connection Shown)
Power
Cord
Ground
Wire
Connect
Center
Screw
Summary of Contents for DPGT750ECPL - Profile Harmony 7.3 cu. Ft. Electric Dryer