background image

EXHAUST INFORMATION (continued)

EXHAUST SYSTEM CHECK LIST

HOOD OR WALL CAP

‡ 7HUPLQDWHLQDPDQQHUWRSUHYHQWEDFNGUDIWVRUHQWU\RI

ELUGVRURWKHUZLOGOLIH

‡ 7HUPLQDWLRQ VKRXOG SUHVHQW PLQLPDO UHVLVWDQFH WR WKH

H[KDXVWDLUÀRZDQGVKRXOGUHTXLUHOLWWOHRUQRPDLQWHQDQFH
WRSUHYHQWFORJJLQJ

‡ 1HYHU LQVWDOO D VFUHHQ LQ RU RYHU WKH H[KDXVW GXFW 7KLV

FRXOGFDXVHOLQWEXLOGXS

‡ :DOO FDSV PXVW EH LQVWDOOHG DW OHDVW  LQ DERYH JURXQG

OHYHORUDQ\RWKHUREVWUXFWLRQZLWKWKHRSHQLQJSRLQWHGGRZQ

SEPARATION OF TURNS

)RU EHVW SHUIRUPDQFH VHSDUDWH  DOO WXUQV E\ DW OHDVW  IW

of straight duct, including distance between last turn and 

H[KDXVWKRRGZDOOFDS,IWZRWXUQVPXVWEHFORVHUWKDQIW

GHGXFWIWIURPWKHPD[LPXPOHQJWKVVKRZQLQWKHWDEOH
IRUHDFKRFFXUUHQFH

TURNS OTHER THAN 90º

‡ 2QHWXUQRIžRUOHVVPD\EHLJQRUHG
‡ 7ZRžWXUQVVKRXOGEHWUHDWHGDVRQHžWXUQ
‡ (DFKWXUQRYHUžVKRXOGEHWUHDWHGDVRQHžWXUQ

SEALING OF JOINTS

‡ $OO MRLQWV VKRXOG EH WLJKW WR DYRLG OHDNV 7KH PDOH HQG RI

HDFKVHFWLRQRIGXFWPXVWSRLQWDZD\IURPWKHGU\HU

‡ 7KH GXFW VKDOO QRW EH DVVHPEOHG ZLWK VFUHZV RU RWKHU

IDVWHQLQJPHDQVWKDWH[WHQGLQWRWKHGXFWDQGFDWFKOLQW

‡ 'XFWMRLQWVFDQEHPDGHDLUDQGPRLVWXUHWLJKWE\ZUDSSLQJ

WKHRYHUODSSHGMRLQWVZLWKGXFWWDSH

INSULATION

Duct work that runs through an unheated area or is near air 
conditioning should be insulated to reduce condensation and 

OLQWEXLOGXS
‡ +RUL]RQWDO UXQV VKRXOG VORSH GRZQ WRZDUG WKH RXWGRRUV

LQFKSHUIRRW

4

Installation Instructions

SIDE OR BOTTOM EXHAUST

THIS DRYER COMES READY FOR REAR 

EXHAUSTING. IF SPACE IS LIMITED, USE 

THESE INSTRUCTIONS TO EXHAUST 

DIRECTLY FROM THE SIDE OR BOTTOM OF 

THE CABINET.

‡1HYHUXVHÀH[LEOHGXFWLQVLGHGU\HU

  

'HWDFKDQGUHPRYHWKHGHVLUHGNQRFNRXW

  

5HPRYH WKH VFUHZ LQVLGH WKH GU\HU H[KDXVW GXFW DQG VDYH
3XOOWKHGXFWRXWRIWKHGU\HU3URWHFWVKDUSHGJHVDURXQGWKH
NQRFNRXWDQGH[KDXVWRSHQLQJZLWKWKHWDSH

&XWWKHGXFWDVVKRZQ.HHSSRUWLRQ$

7KURXJKWKHUHDURSHQLQJORFDWHWKHWDELQWKHPLGGOHRIWKH

GU\HUEDVH/LIWWKHWDEWRDERXWƒXVLQJDÀDWVFUHZGULYHU

5HFRQQHFWDQGVHFXUHWKHFXWSRUWLRQ$RIWKHGXFWWRWKH

EORZHU KRXVLQJ 0DNH VXUH WKDW WKH ¿[LQJ KROH LV DOLJQHG
ZLWKWKHWDELQWKHEDVH8VHWKHVFUHZRILWHPWRVHFXUH
WKHGXFWLQSODFHWKURXJKWKHWDERQWKHGU\HUEDVH

8VHVWDQGDUGPHWDOHOERZVDQGGXFWWRFRPSOHWHH[KDXVW

V\VWHP,QVHUWVWDQGDUGHOERZDQGGXFWVWKURXJKUHDUDQG
VLGHRUERWWRPRSHQLQJV

&RYHUWKHRSHQLQJDWWKHEDFNZLWKWKHSODWH.LW:(0

DYDLODEOHIURP\RXU/RFDO6HUYLFH3URYLGHU

PARTS AVAILABLE FROM LOCAL SERVICE 

ORGANIZATION

5LJLG0HWDO'XFW&RPSRQHQWV

 

:;;µ;·'XFW

 

:;;µ[·'XFW

 

:;;µ(OERZ

 

:;;$RRG

)OH[LEOH0HWDO'XFW&RPSRQHQWV

 

:;;µGLD)OH[LEOH0HWDO6HPL5LJLG

 

8//LVWHG7UDQVLWLRQ'XFWLQFOXGHVHOERZV

9"

A

B

FIXING HOLE

WARNING-

NEVER LEAVE THE 

BACK OPENING WITHOUT THE PLATE. 

 ALCOVE OR CLOSET INSTALLATION

• If your dryer is approved for installation in an alcove or 

FORVHWLWZLOOEHVWDWHGRQDODEHORQWKHGU\HUEDFN

7KH GU\HU

MUST

 EH YHQWHG WR WKH RXWGRRUV 6HH WKH

EXHAUST INFORMATION

VHFWLRQ

0LQLPXP FOHDUDQFH IURP FRPEXVWLEOH VXUIDFHV DQG QRQ

FRPEXVWLEOHVXUIDFHVIRUDLULQWDNHSXUSRVHVLV

LQHLWKHUVLGH
LQIURQWDQGUHDU

NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT THE REAR OF 
THE DRYER, MINIMUM CLEARANCE FROM THE WALL IS 5.5 in.

• 

0LQLPXP YHUWLFDO VSDFH IURP ÀRRU WR RYHUKHDG FDELQHWV
FHLOLQJHWFLVLQ

• Closet doors must be louvered or otherwise ventilated and 

PXVWFRQWDLQDPLQLPXPRIVTLQRIRSHQDUHDHTXDOO\

GLVWULEXWHG,IWKHFORVHWFRQWDLQVERWKDZDVKHUDQGDGU\HU

GRRUVPXVWFRQWDLQDPLQLPXPRIVTLQRIRSHQDUHD
HTXDOO\GLVWULEXWHG

‡7KHFORVHWVKRXOGEHYHQWHGWRWKHRXWGRRUVWRSUHYHQWJDV

SRFNHWLQJLQFDVHRIDJDVOHDNLQWKHVXSSO\OLQH

‡1R RWKHU IXHOEXUQLQJ DSSOLDQFH VKDOO EH LQVWDOOHG LQ WKH

VDPHFORVHWZLWKWKHGU\HU

Summary of Contents for DDC4400TWH

Page 1: ...INSTALLATION INSTRUCTIONS BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTANT 6DYH WKHVH LQVWUXFWLRQV IRU ORFDO LQVSHFWRU V XVH IMPORTANT 2EVHUYH DOO JRYHUQLQJ FRGHV DQG RUGLQDQFHV Note to Installer H VXUH WR OHDYH WKHVH LQVWUXFWLRQV ZLWK WKH FXVWRPHU Note to Customer Keep these instructions with your Owner s Manual for future UHIHUHQFH HIRUH WKH ROG GU HU LV UHPRYHG IURP V...

Page 2: ...opriate ZDOO KRRNV WDNLQJ XS DQ VODFN STEP 7 GMXVW DOO OHYHOOLQJ OHJV U HU PXVW EH OHYHOOHG DQG UHVW UPO RQ DOO OHYHOOLQJ OHJV Installation Instructions STEP 7 Alternate Method for Installation of Wall Hooks STEP 1 If wall studs are not correctly spaced or centered behind upper XQLW LW PD EH QHFHVVDU WR DWWDFK D KRUL RQWDO µ µ ERDUG WR WKH H LVWLQJ ZDOO STEP 2 WWDFK ZDOO KRRNV LQ DSSUR LPDWH SRVLW...

Page 3: ...DWLQJ D SRWHQWLDO UH KD DUG R QRW REVWUXFW LQFRPLQJ RU H KDXVWHG DLU Provide an access for inspection and cleaning of the H KDXVW V VWHP HVSHFLDOO DW WXUQV DQG MRLQWV KDXVW system shall be inspected and cleaned at least once a year In special installations it may be necessary to connect WKH GU HU WR WKH KRXVH YHQW XVLQJ D ÀH LEOH PHWDO IRLO W SH GXFW 8 OLVWHG ÀH LEOH PHWDO IRLO W SH GXFW PD EH XVH...

Page 4: ...G VDYH 3XOO WKH GXFW RXW RI WKH GU HU 3URWHFW VKDUS HGJHV DURXQG WKH NQRFNRXW DQG H KDXVW RSHQLQJ ZLWK WKH WDSH XW WKH GXFW DV VKRZQ HHS SRUWLRQ 7KURXJK WKH UHDU RSHQLQJ ORFDWH WKH WDE LQ WKH PLGGOH RI WKH GU HU EDVH LIW WKH WDE WR DERXW XVLQJ D ÀDW VFUHZGULYHU 5HFRQQHFW DQG VHFXUH WKH FXW SRUWLRQ RI WKH GXFW WR WKH EORZHU KRXVLQJ 0DNH VXUH WKDW WKH LQJ KROH LV DOLJQHG ZLWK WKH WDE LQ WKH EDVH 8VH...

Reviews: