Ducting Materials: 

4-way via rear, right, left and bottom. 

Exhaust Length Calculation:

 

1.   Determine the number of 90° turns needed for your installation. If you exhaust 

to the side or bottom of dryer, add one turn.

2.   The maximum length of 4" rigid (aluminum or galvanized) duct which can be  

tolerated is shown in the table. The maximum length for flexible ducts are  
less than for rigid duct.

  A turn of 45° or less may be ignored. Two 45° turns within the duct length should  
  be  treated as a 90° elbow.  
  A turn over 45° should be treated as a 90° elbow.

Exhausting the dryer to the outside is strongly recommended

 to prevent large 

amounts of moisture and lint from being blown into the room. Gas dryers or any  
dryer located in a closet 

must

 be exhausted to the outside.

Caution:

 For personal safety do not terminate exhaust into a chimney, under any 

enclosed house floor (crawl space), or into an attic, since the accumulated lint could 
create a fire hazard or moisture could cause damage. Never terminate the exhaust 
into a common duct or plenum with a kitchen exhaust, since the combination of lint 
and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, 
bird nesting, etc. The wall cap must also be located at least 12" above the ground or 
any other obstruction with the opening pointed down.
Other terminations, such as louvered wall boxes, are acceptable provided they are 
equivalent to a 4" opening dampered wall cap.

For more information on venting kits and accessories, please call 1-800-GE CARES.

Special Installation Requirements

 

Alcove or Closet Installation:

 

•  If your dryer is approved for installation in an alcove or closet, it will be stated on 

a label on the dryer back.

• The dryer MUST be exhausted to the outside
•  Minimum clearances between dryer cabinet and adjacent walls or other surfaces 

are: 0" either side and 3" front and rear

• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
•  Closet doors must be louvered or otherwise ventilated and must contain a  

minimum of 60 sq. in. of open area equally distributed. If this closet contains both 
a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area 
equally distributed.

•  No other fuel-burning appliance shall be installed in the same closet with a gas 

dryer. 

DCCH43EF/GF 

GE

®

 5.7 Cu. Ft. Commercial Frontload Dryer

Dryer Exhausting Information — Use Metal Duct Only  

Vertical and Horizontal Ducting

 

 

 

150 ft. 

127 ft. 

75 ft. 

52 ft.

 

 

140 ft. 

117 ft. 

65 ft. 

42 ft.

 

 

130 ft. 

107 ft. 

55 ft. 

32 ft.

7.3 capacity electric  

120 ft. 

97 ft. 

45 ft. 

22 ft.

and gas dryers 

110 ft. 

87 ft. 

35 ft. 

12 ft.

 

 

90 ft. 

60 ft. 

55 ft. 

45 ft.

 

 

60 ft. 

45 ft. 

40 ft. 

30 ft.

7.0 and 6.0  

45 ft. 

35 ft. 

30 ft. 

20 ft.

capacity models 

35 ft. 

25 ft. 

20 ft. 

15 ft.

all electric dryers 

25 ft. 

15 ft. 

15 ft. 

10 ft.

 

 

90 ft. 

60 ft. 

55 ft. 

45 ft.

7.0 and 6.0  

60 ft. 

45 ft. 

40 ft. 

30 ft.

capacity models 

45 ft. 

35 ft. 

30 ft. 

20 ft. 

all gas dryers 

35 ft. 

25 ft. 

20 ft. 

15 ft.

 

 

60 ft. 

48 ft. 

30 ft. 

18 ft.

 

 

52 ft. 

40 ft. 

22 ft. 

14 ft.

 

 

44 ft. 

32 ft. 

14 ft. 

10 ft.

5.7 capacity electric  

32 ft. 

24 ft. 

— 

and gas dryers 

28 ft. 

16 ft. 

— 

— 

Number

of

90°

turns

Maximum length of 4"

dia. 

rigid metal 

duct 

Maximum length of 4"

dia. 

flexible metal 

duct 

Exhaust hood type

Exhaust hood type

Domestic  

dryer models

A

4" opening

B

2-1/2"

 

opening

A

4" opening

B

2-1/2"

 

opening

Best performance

A

B

2-1/2

4

GE Dryer Vent

A

B

2-1/2

4

GE Dryer Vent

A

Reviews: