STOP!

What type of bulbs do you plan to use? 

You may need to install a Bulb Adaptor.

Some installations require the included Bulb Adaptor to maintain Wi-Fi

connectivity and to ensure your switch and bulbs work together.

If your switch circuit includes a load of at least 15 Watts:

TYPE OF LIGHT BULB

IS AN ADAPTOR REQUIRED?

Incandescent/Halogen

No

Dimmable LEDs

No

Non-Dimmable LEDs

Yes

Cync or C by GE smart lights

Yes

If your switch circuit does 

NOT

 include a load of at least 15 Watts:

TYPE OF LIGHT BULB

IS AN ADAPTOR REQUIRED?

Incandescent/Halogen

Yes

Dimmable LEDs

Yes

Non-Dimmable LEDs

Yes

Cync or C by GE smart lights

Yes

Installing the Bulb Adaptor

If the Bulb Adaptor does not fit your bulb or fixture, you have other options:
•  Replace your lights with incandescent, halogen, or dimmable LED light 

bulbs that meet the 15 Watt minimum load requirement. See a list of  

compatible bulbs at gelighting.com/cync

•  Install our Fixture Adaptor to the actual fixture in the ceiling. For install 

instructions and where to get a C by GE or Cync Fixture Adaptor 

(available separately), contact Customer Support at 1-844-302-2943

STEP 1

Twist the Bulb Adaptor onto the base of the 

medium-base (E26) light bulb.

STEP 2

Screw the bulb and Adaptor into the fixture.

NOTE: Only one Bulb Adaptor is needed per 

switch, even if there are multiple light bulbs 

on the circuit. If installing in a recessed can 

application, you may need to adjust the 

recessed can depth to ensure the bulb is flush.

Summary of Contents for Cync CSWONBLBWF1NN

Page 1: ...Smart Wall Switch 3 Wire Installation Guide 3 Wire Smart Switches Dimmers Models CSWONBLBWF1NN CSWONBLPWF1NN CSWONBLTWF1NN CSWDMOCBWF1NN CSWDMBLBWF1NN...

Page 2: ...providing an air gap as per National Electrical Code NEC ANSI NFPA 70 article 404 and Canadian Electric Code Part 1 CEC Simple DIY Set Up STEP 1 Install your Smart Switch STEP 2 Download the Cync App...

Page 3: ...luded Bulb Adaptor Use the optional Fixture Adaptor available separately where the Bulb Adaptor will not fit Contact Customer Support at 1 844 302 2943 for details IMPORTANT NOTE ON 3 WAY WIRING Some...

Page 4: ...your system is up to date and you update the rmware when prompted for the best experience BEFORE YOU DO ANYTHING Turn Off the Power STEP 1 Turn off the power for the switch location at the circuit bre...

Page 5: ...ling the Bulb Adaptor If the Bulb Adaptor does not fit your bulb or fixture you have other options Replace your lights with incandescent halogen or dimmable LED light bulbs that meet the 15 Watt minim...

Page 6: ...confirm power to the switch is off recommended STEP 3 Before disconnecting the wires from the wall label each with the provided wire labels Ground wire is required If you don t have this wire the Cyn...

Page 7: ...multi way traveler wire if applicable For 3 way switch setup visit gelighting com cync Attention Incorrectly connecting the ground wire from the wall to the ground wire on the switch will damage the p...

Page 8: ...arrow on the switch is pointing up Secure the Smart Switch STEP 1 Using a Phillips screwdriver and the screws provided secure the switch to the wall until level and flush Then snap the faceplate cove...

Page 9: ...to the Cync App LED indicator light or light ring will not illuminate if wired incorrectly or if the switch circuit does not meet the specified load requirements If lights don t turn on STEP 1 Check t...

Page 10: ...s TRYTHIS Alexa turn off the living room Alexa turn on the bedroom HEY GOOGLE To set up open the Hey Google or Google Home app search for the Cync action follow the setup instructions TRYTHIS Hey Goog...

Page 11: ...a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules and Industry Canad...

Page 12: ...ply before servicing Operation temperature 0 40 C For Control of Electronic Ballast CFLs LED and LED Lamps Type 1 Enclosure IP20 Pollution Degree 2 Impulse Voltage 2500V Type 1 action Indoor use only...

Page 13: ...PK 00102798 3...

Reviews: