Smart Wall Switch

3-Wire 

Installation Guide

3-Wire Smart Switches & Dimmers

Models

CSWONBLBWF1NN

CSWONBLPWF1NN

CSWONBLTWF1NN

CSWDMOCBWF1NN

CSWDMBLBWF1NN

Summary of Contents for CSWDMBLBWF1NN

Page 1: ...Smart Wall Switch 3 Wire Installation Guide 3 Wire Smart Switches Dimmers Models CSWONBLBWF1NN CSWONBLPWF1NN CSWONBLTWF1NN CSWDMOCBWF1NN CSWDMBLBWF1NN ...

Page 2: ... providing an air gap as per National Electrical Code NEC ANSI NFPA 70 article 404 and Canadian Electric Code Part 1 CEC Simple DIY Set Up STEP 1 Install your Smart Switch STEP 2 Download the Cync App powered by Savant on your smartphone STEP 3 Add your Smart Switch to the Cync App For set up help visit gelighting com cync GE and C by GE are trademarks of General Electric Company Used under tradem...

Page 3: ...cluded Bulb Adaptor Use the optional Fixture Adaptor available separately where the Bulb Adaptor will not fit Contact Customer Support at 1 844 302 2943 for details IMPORTANT NOTE ON 3 WAY WIRING Some lights have one wall switch while others are controlled by two or more wall switches such as stair lights which have a switch at both the top and bottom of the stairs If your lights have more than on...

Page 4: ...your system is up to date and you update the firmware when prompted for the best experience BEFORE YOU DO ANYTHING Turn Off the Power STEP 1 Turn off the power for the switch location at the circuit breaker box STEP 2 Test existing switch by toggling switch on off ensuring lights do not turn on STEP 3 Now follow these setup steps for a single gang switch ON OFF ...

Page 5: ...lling the Bulb Adaptor If the Bulb Adaptor does not fit your bulb or fixture you have other options Replace your lights with incandescent halogen or dimmable LED light bulbs that meet the 15 Watt minimum load requirement See a list of compatible bulbs at gelighting com cync Install our Fixture Adaptor to the actual fixture in the ceiling For install instructions and where to get a C by GE or Cync ...

Page 6: ...o confirm power to the switch is off recommended STEP 3 Before disconnecting the wires from the wall label each with the provided wire labels Ground wire is required If you don t have this wire the Cync or C by GE Smart Switch is not compatible STEP 4 Disconnect wires and remove existing switch Line Load Line Load Ground Wire Labels ...

Page 7: ... multi way traveler wire if applicable For 3 way switch setup visit gelighting com cync Attention Incorrectly connecting the ground wire from the wall to the ground wire on the switch will damage the product STEP 5 Cap the neutral wire from the wall if applicable Neutral wire is not required to operate this switch NOTE Both black wires on the switch are interchangeable and can be connected to eith...

Page 8: ...e arrow on the switch is pointing up Secure the Smart Switch STEP 1 Using a Phillips screwdriver and the screws provided secure the switch to the wall until level and flush Then snap the faceplate cover onto the bracket If using your existing wall plate you may need to replace the existing wall plate screws with the short screws provided ...

Page 9: ... to the Cync App LED indicator light or light ring will not illuminate if wired incorrectly or if the switch circuit does not meet the specified load requirements If lights don t turn on STEP 1 Check that power to the switch is on at the breaker STEP 2 Turn power off at the breaker return to the switch to confirm the wires are securely and properly wired according to the installation guide STEP 3 ...

Page 10: ...ns TRYTHIS Alexa turn off the living room Alexa turn on the bedroom HEY GOOGLE To set up open the Hey Google or Google Home app search for the Cync action follow the setup instructions TRYTHIS Hey Google turn on the lights Hey Google good morning Hey Google I m leaving For set up help visit gelighting com cync GE and C by GE are trademarks of General Electric Company Used under trademark license A...

Page 11: ... a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules and Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 This device may not cause interference 2 This device must accept any interference received including interferenc...

Page 12: ...pply before servicing Operation temperature 0 40ºC For Control of Electronic Ballast CFLs LED and LED Lamps Type 1 Enclosure IP20 Pollution Degree 2 Impulse Voltage 2500V Type 1 action Indoor use only TM Like your new Smart Switch Share your experience Leave a review where you purchased the product ...

Page 13: ...PK 00102798 3 ...