SMBus 2
SMBus two connects the CM6 board specific serial devices. Following devices
and address scheme are used.
Address:
1101 110x
clock device ICS9FG104
1001 100x
Thermo Sensor LM86
1010 01xx
User EEPROM 128kByte
1010 00xx
SPD and Factory EEPROM 256Bytes