– 69 –
The circulation pump turns on, water pressure
causes the diverter plate to rise and index 1/8 turn.
7KHSXPSWXUQVRȺUHVXOWLQJLQWKHGLYHUWHUSODWH
to lower and index 1/8 turn. This repeats until the
diverter reaches the position the control is set for.
Diverter Position Sensor
A diverter sensor is used to detect the position of the
diverter. A sensor contains two reed switches used
on the outside of the diverter. The sensor is part of
the DC harness. This sectioned illustration of the
bottom of the diverter has been sectioned to show
magnets located on the bottom of the diverter plate.
The diverter is only available as an assembly.
The Diverter is the key component which allows
lower water use, by alternating water to the lower
spray arm, silverware wash, mid/upper spray
system (bottle wash, mid spray arm and upper spray
system) or lower spray arm reverse bottle wash and
upper spray system.
Operation
The rotation of the power diverter is counter-
clockwise as viewed from the top. The control will
seek the lower primary as the start of the circulation
cycle. Lower reverse and silverware wash are only
used during the main wash segment of a cycle. A
short spray will be detected from the silverware
wash, mid and upper spray systems as well as the
lower reverse until the diverter is positioned to the
lower primary port.
Pressure Diverter
Mid, Upper &
Bottle Wash
Lower
Reverse
Silverware Wash
Lower Primary
Magnets
Sensor
Cut Away Section
(
Continued next page
)