45
Performance Data Sheet
Model: GE RPWF
Use Replacement Cartridge RPWF.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible
limit for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53. System tested and certified by NSF International against
NSF/ANSI Standard 42 and Standard 53 for the reduction of substances listed below.
The following pharmaceutical reduction claims have not been certifi ed by NSF International. Claims tested and verifi ed
by independent laboratory:
Contaminant
Reduction
Average Infl uent
NSF specifi ed
Challenge Concentration
Avg %
Reduction
Average Product Water
Concentration
Max Permissible
Product Water
Concentration
NSF
Test Report
Atenolol
1088 ng/L
N/A
99.5%
5.0 ng/L
N/A
J-00103221
Fluoxetine
845 ng/l
N/A
99.4%
5.0 ng/L
N/A
J-00103221
Ibuprofen
898 ng/L
N/A
98.8%
9.9 ng/L
N/A
J-00103726
Progesterone
945 ng/L
N/A
99.4%
5.5 ng/L
N/A
J-00103727
Trimethoprim
403 ng/L
N/A
99.5%
2.0 ng/L
N/A
J-00103221
34-8708-7119-0
EPA #070595-MEX-001
© 2012 General Electric Company PC71879
It is essential that the manufacturer’s recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
See Installation Manual for Warranty information.
Application Guidelines/Water Supply Parameters
Service Flow
0.5 gpm (1.89 lpm)
Water Supply
Potable Water
Water Pressure
25-120 psi (172– 827 kPa)
Water Temperature
33º F - 100º F (0.6º C - 38º C)
Note:
While the testing was performed under standard laboratory conditions,
actual performance may vary.
Replacement Cartridge: RPWF. For estimated costs of replacement elements
please call 1-800-626-2002 or visit our website at www.geapplianceparts.com.
WARNING
To reduce the risk associated with ingestion of contaminants:
A
y
t
il
a
u
q
n
w
o
n
k
n
u
f
o
r
o
e
f
a
s
n
u
y
ll
a
c
i
g
o
l
o
i
b
o
r
c
i
m
s
i
t
a
h
t
r
e
t
a
w
h
t
i
w
e
s
u
t
o
n
o
D
without adequate disinfection before and after the system.
Systems certifi ed
for cyst reduction may be used on disinfected water that may contain fi lterable
cysts. EPA Establishment Number 070595-MEX-001.
NOTICE
To reduce the risk associated with property damage due to water leakage:
D
Read and follow
use instructions before installation and use of this system.
D5
stallation and use
MUST
comply with all state and local plumbing codes.
D
Do not
install if water pressure exceeds 120 psi (827 kPa). If your water pressure
exceeds 80 psi, you
must
install a pressure-limiting valve. Contact a plumbing
professional if you are uncertain how to check your water pressure.
K
Do not
install where water hammer conditions may occur. If water hammer
conditions exist you
must
install a water hammer arrester. Contact a plumbing
professional if you are uncertain how to check for this condition.
K
Do not
install on hot water supply lines. The maximum operating water
temperature of this fi lter system is 100º F (38º C).
K
Protect fi lter from freezing.
Drain fi lter when temperatures drop
below 33ºF (0.6ºC).
fi
e
l
b
a
s
o
p
s
i
d
e
h
T
K
lter cartridge
must
be replaced every
6
months at the
rated capacity, or sooner if a noticeable reduction in fl ow rate occurs.
For conditions of use, health claims certified by the California Department of Public
Health, and replacements, see performance data sheet. California Department
of Public Health Certification #11-2110. The contaminants or other substances
removed or reduced by this water filter are not necessarily in all users’ water.
Capacity 170 Gallons (643.5 Liters). Contaminant Reduction Determined by NSF testing.
Substance Tested
for Reduction
Average Infl uent
NSF specifi ed
Challenge Concentration
Avg %
Reduction
Average Product
Water
Concentration
Max Permissible
Product Water
Concentration
NSF Reduction
Requirements
NSF
Test Report
Chlorine Taste and Odor
2.0 mg/L
2.0 mg/L ± 10%
97.4%
0.05 mg/L
N/A
≥50%
J-00102044
Nominal Particulate
Class I, , ≥0.5 to < 1.0 μm 7,633,333 pts/mL
At least 10,000 particles/mL
99.0%
71,850 pts/ml
N/A
≥85%
J-00106249
Asbestos
109 MFL
10
7
to 10
8
fi bers/L; fi bers
greater than 10μm in length
99.99%
<1 MFL
N/A
≥99%
J-00102069
Atrazine
0.009 mg/L
0.009 mg/L ± 10%
94.4%
0.0005 mg/L
0.003 mg/L
N/A
J-00102058
Benzene
0.016 mg/L
0.015 mg/L ± 10%
96.4%
0.001 mg/L
0.005 mg/L
N/A
J-00102065
Carbofuran
0.08 mg/L
0.08 mg/L ± 10%
98.8%
0.001 mg/L
0.04 mg/L
N/A
J-00102059
Cyst*
104,750 cysts/L
Minimum 50,000 cysts/L
99.99%
3 cyst/L
N/A
≥99.95%
J-00102057
Lead pH @6.5
0.140 mg/L
0.15 mg/L ± 10%
99.3%
0.001 mg/L
0.010 mg/L
N/A
J-00102052
Lead pH @8.5
0.158 mg/L
0.15 mg/L ± 10%
98.3%
0.002 mg/L
0.010 mg/L
N/A
J-00102053
Mercury @ pH 6.5
0.006 mg/L
0.006 mg/L ± 10%
91%
0.0003 mg/L
0.002 mg/L
N/A
J-00102054
Mercury @ pH 8.5
0.006 mg/L
0.006 mg/L ± 10%
88.3%%
0.0007 mg/L
0.002 mg/L
N/A
J-00104087
Lindane
0.002 mg/L
0.002 mg/L ± 10%
99%
0.00002 mg/L
0.0002 mg/L
N/A
J-00102063
P-Dichlorobenzene
0.222 mg/L
0.225 mg/L ± 10%
99.8%
0.0005 mg/L
0.075 mg/L
N/A
J-00102067
Toxaphene
0.015 mg/L
0.015 mg/L ± 10%
93.5%
0.001 mg/L
0.003 mg/L
N/A
J-00102061
2, 4-D Reduction
0.218 mg/L
0.210 mg/L±10%
99.9%
0.0001 mg/L
0.07 mg/L
N/A
J-00102064
0
7
0
2
0
1
0
0
-
J
%
5
9
≥
A
/
N
L
/
g
m
5
1
0
0
.
0
%
7
.
7
9
%
0
1
±
L
/
g
m
0
0
3
.
0
L
/
g
m
8
7
2
.
0
C
O
V
*Based on the use of Cryptosporidium parvum oocysts.
REPLACEMENT
T
N
E
M
E
L
E
System tested and certifi ed by NSF
International against NSF/ANSI Standard
42 and Standard 53 in model GE RPWF
for the reduction of the claims specifi ed
on the performance data sheet.
GE
Appliances
Appliance Park
Louisville, KY 40225
geapplianceparts.com