background image

CSB48WSK 

GE Café

 Series 48" Built-In Side-By-Side Refrigerator

Total volume and shelf 

area are calculated by 

the Association of Home 

Appliance Manufacturers’ 

standards.

Listed by 

Underwriters 

Laboratories

Specification Revised 3/16

For answers to your Monogram, GE Café

 Series, GE Profile

 Series or 

GE Appliances product questions, visit our website at geappliances.com 
or call GE Answer Center

®

 Service, 800.626.2000.

GROUNDING THE REFRIGERATOR
IMPORTANT—PLEASE READ CAREFULLY
FOR PERSONAL SAFETY, THIS APPLIANCE 

MUST BE PROPERLY GROUNDED.

The power supply cord of this appliance is 

equipped with a three-prong (grounding) plug 
which mates with a standard three-prong 
(grounding) wall receptacle to minimize the 
possibility of electric shock hazard from this 
appliance.
Have the wall outlet and circuit checked by a 
qualified electrician to make sure the outlet is 
properly grounded.
Where a standard 2-prong wall outlet is 
encountered, it is your personal responsibility 
and obligation to have it replaced with a properly 
grounded 3-prong wall outlet.

DO NOT, UNDER ANY  

CIRCUMSTANCES, CUT  

OR REMOVE THE THIRD  

(GROUND) PRONG FROM  

THE POWER CORD.
DO NOT USE AN ADAPTER PLUG  

TO CONNECT THE REFRIGERATOR  

TO A 2-PRONG OUTLET.
DO NOT USE AN EXTENSION CORD  

WITH THIS APPLIANCE.

DIMENSIONS AND INSTALLATION 

INFORMATION 

SIDE PANELS

Side panels (not supplied) 

must be used whenever  

the sides of the refrigerator 
will be exposed. The 1/4" 

side panels will slip into 
the side case trim. Order 

side panels from your 

cabinet manufacturer.

* Depending on installation 

height.

*Finished Width

Electrical

Area

84 1/2" max

83 1/2" min

Finished

Opening

74"

From Floor

to Bottom

of Electrical

24"

5"

5"

3 1/2"

Water 

Supply

3 1/2"

3"

7"

7"

24"

*84"

*3" to 4"

1-1/2"

THE INSTALLATION SPACE

FLOORING

For proper installation, this refrigerator must be 
placed on a level surface of hard material that 
is at the same height as the rest of the flooring. 
This surface should be strong enough to support 
a fully loaded refrigerator, or approximately 1500 
lbs.

NOTE:

 Protect the finish  of the flooring. Cut a 

large section of the cardboard carton and place 
under the refrigerator where you are working.

WATER AND ELECTRICAL LOCATIONS

The opening must  be prepared with the 
electrical and water supply located as shown.

THE CUTOUT DEPTH MUST BE 24"

The refrigerator will project forward, slightly 
beyond adjacent cabinets, depending on your 
installation.

ADDITIONAL SPECIFICATIONS

A 120 volt, 60Hz, 15 or 20 amp power supply is 
required. An individual properly grounded branch 
circuit or circuit breaker is recommended. Install 
a properly grounded 3-prong electrical receptacle 

recessed into the back wall. Electrical must be located 
on rear wall as shown.

NOTE:

 GFI (ground fault interrupter) is not 

recommended.
Water line can enter the opening through the floor or 
rear wall. The water line installed should be 1/4" O.D. 
copper tubing or GE SmartConnect™ tubing between 
the cold water line and water connection location. The 
line should be long enough to extend to the front of the 
refrigerator. Installation of an easily accessible shutoff 
valve in the water line is required.

* The  finished   

cutout width must 

be: 41-1/2" for  

42" models