Table 5 -Performa 960 FA Level I Programming Parameters
Parameter
Range of Values
Minimum
Increments
Default
Units of Measure
Notes
Name
Description
P1
Time of day
AM or PM
1:00 to 12:59
00:00 to 23:59
1
None
Hour: minute
Range depends on value selected
for P13. Enter the current time.
P2
Time of day of
regeneration
1:00 to 12:59
AM or PM
00:00 to 23:59
1
2:00 AM
Hour: minute
Range depends on value selected
for P13. Skip this parameter to
accept the default or enter a new
time.
P3
Factor A
3 to 250
30 to 2500
1
10
10
100
PPM
PPM x 10
Unit of measure depends on value
selected for P12. Enter potassium
permanganate demand.
P4
Regenerant
Dosage
0.5 to 99.5
01 to 25.5
0.5
0.1
6
2.5
Gallons x 10
Liters x 10
Unit of measure depends on value
selected for P12.
Select regenerant dosage from
Table 6 and enter that value.
P5
Capacity of Unit
0.1 to 140.0
0.01 to 14.00
0.1
0.01
1.0
0.1
PPM-gallons
PPM-liters
Unit of measure depends on value
selected for P12.
Enter the system capacity setting
from Table 7.
Table 6 - Regenerant Dosage Settings (gallons x 10) for Various Size Iron Filters
Temperature
Filter Size/Cubic Feet of Manganese Greensand
0.75 ft
3
1.00 ft
3
1.25 ft
3
1.50 ft
3
1.75 ft
3
2.00 ft
3
2.50 ft
3
3.00 ft
3
3.50 ft
3
50
°
F
4.0
5.0
6.0
8.0
9.0
10.0
13.0
15.0
18.0
60
°
F
3.0
4.0
5.0
6.0
7.0
9.0
9.0
11.0
13.0
70
°
F
3.0
3.0
3.0
4.0
4.0
5.0
6.0
8.0
9.0
Table 7 - Capacity Settings for Various Size Iron Filters
Filter Size
0.75 ft
3
1.00 ft
3
1.25 ft
3
1.50 ft
3
1.75 ft
3
2.00 ft
3
2.50 ft
3
3.00 ft
3
3.50 ft
3
Capacity Setting
7.5
10
12.5
15
17.5
20
25
30
35