White 

D1/D+/Data, may be used for D1 (Wiegand data), D+ 

(RS485 data), magnetic stripe data. Normal operating 
voltage 0 to +5 V (absolute max12 V). 
The RAS is connected to the ATS panel via the RS485 data 

bus, up to 1.5 km from the control panel or the 4-door DGP. 
Use the 2-pair twisted, shielded data cable (WCAT52/54 is 
recommended). The shield of any bus cable must be 
connected to system ground at one end only. The ATS111x 
RAS is not provided with an Earth connection for this 
purpose. If the bus is ‘daisy-chained’ to the RAS, ensure 

that the shield of the cable is joined to provide continuity of 
data cable shield. 

Blue 

Buzzer/Beeper, may be used for offline buzzer control.  
Wire open or +5 to 12 V: buzzer off (absolute maximum is 
+14 V).  
Wire grounded (0 V): buzzer on. 

Brown 

Application depends on selection of RAS menu option 2 —
offline LED control. See programming. 

Yellow 

 

Application depends on selection of RAS menu option 2 —

offline LED control (see programming). When not used for 
two wire LED control, yellow wire may be used for  

• 

RTE input when online to ATS,  

• 

connection to a simple push button for operation in RTE

Only mode, 

• 

connection to a button for use in RTE + Arm/Disarm

mode.  

Button should be connected to GND. See 10—RTE (Egress) 
Control. 

Violet 
 

Open collector output, configurable as Door output, 

Tamper output, or magnetic stripe data present. This is a 
low current output and must not be used to directly 

energize high current door openers. (Absolute maximum is 
14 V @ 50 mA) 

 

When using a door control relay, always place a 
suppression diode (e.g. a 1N4001) across the 
relay coil. 

Status LED indications (figure  ) 

Connected to ATS control panel or access control panel 

Green/Red 
(disarm/arm) 

Green:

 when all areas assigned to the RAS alarm 

group are disarmed or when screensaver is active. 

Flashing green when running on battery (mains power 
off) or during unlock time when area disarmed. 

Red:

 if all areas assigned to the RAS alarm group are 

armed. Flashing red during unlock time when area 
armed. 

LED off:

 if at least one and less than all areas assigned 

to the RAS alarm group are armed. 

Yellow (ready) 

Active when all zones in areas assigned to the RAS are 
normal (or active if RAS configured as ATS1156). 

Red (alarm) 

Flashing when any areas assigned to the RAS is in 
alarm state. 

Connected to a Wiegand or Magnetic Stripe interface 

Green/Red 
 

Green: 

On when yellow wire is at 0 V. 

Red: 

On when brown wire is at 0 V. 

Yellow: 

On when yellow AND brown wire at 0 V. 

LED off: 

When yellow and brown wire are between 5 – 

14 V. 

Yellow  

Not used 

Red 

Not used 

 

In offline mode, the TERM switch (DIP switch 5) must be ‘off’ (up). 
DIP switches 1 to 4 are not used in offline mode. 

Operating features  

Night light 

The reader will be dimly lit when enabled. 

Beeper tone 

Press and hold the * key while pressing the 1 key to raise the tone 
frequency or the 2 key to lower the tone frequency. 

Power up 

Upon initial power up, the buzzer will sound two beeps indicating that 
the internal non-volatile memory is OK. All of the area LEDs may 
illuminate indicating that the system is armed. All areas must be 
disarmed in order to enable access to the installer programming menu 
options. 

Troubleshooting 

General faults 

No LED display or keypad backlight: 

• 

Verify the +13.8 and 0 V wire connections on both the RAS and the 

power supply. 

• 

Verify power output on the control panel, 4-door DGP, or external 

power supply. 

All three status LEDs are flashing: 

• 

Verify the D+ and D- wire connections (may be reversed or open 

circuit). 

• 

Verify the address DIP switches of the RAS are set to the proper 

address. 

• 

Verify that the control panel or 4-door controller is polling the RAS 

address. 

The RAS does not respond to a Smart Card: 

• 

The RAS may not be programmed correctly or card beep and LED 

flash may be disabled. Refer Programming for details. 

• 

The Smart Card may not be programmed for use with the 
particular system. 

Rx and Tx LED Indications 

Rx and Tx LEDs are provided on the circuit board to assist in fault 
diagnosis and are visible when the rear plastic cover is removed.  

Rx

:   The yellow Rx LED flashes to indicate polling data is being received 

on the system bus from the panel. If the LED does not flash, the 
control panel is not operational or the bus is faulty (usually cabling). 

Tx

:   The red Tx LED flashes to indicate the RAS is replying to polling 

from the control panel. If the Rx LED flashes but the Tx LED does 
not, the RAS is not programmed to be polled in the control panel or 
is addressed incorrectly. 

Configuring the ATS 1197 RAS 

To configure the RAS: 

• 

Press 19 [ENTER] followed by * 3 [ENTER. 

• 

Type the required RAS address (2 – 16). followed by [ENTER]. 

• 

Select the RAS. 

• 

Disable the option ’LCD Arming Station’. 

• 

Enable the option ‘3 LED RAS’. 

Summary of Contents for ATS1197

Page 1: ... the BUS or the system management software to program polling and set up the required items for the new RAS In particular the ATS1197 RAS must be programmed as a non LCD RAS 11 Check that the ATS1197 is communicating correctly and verify that the tamper switch is working properly i e RAS Tamper is not showing on the LCD RAS WARNING All power should be turned off to the control panel before wiring ...

Page 2: ...igned to the RAS is in alarm state Connected to a Wiegand or Magnetic Stripe interface Green Red Green On when yellow wire is at 0 V Red On when brown wire is at 0 V Yellow On when yellow AND brown wire at 0 V LED off When yellow and brown wire are between 5 14 V Yellow Not used Red Not used In offline mode the TERM switch DIP switch 5 must be off up DIP switches 1 to 4 are not used in offline mod...

Page 3: ...or Magnetic stripe See option 16 for more data on transmitted data details Menu 6 Card beep If enabled default the beeper will give a short beep when a card is badged The panel controls subsequent beeper activity Menu 7 Watchdog Offline mode only If enabled one byte of data is sent to the host every minute to indicate that the RAS is connected and operating normally If the ATS1197 tamper is active...

Page 4: ...kann 5 Schließen Sie das Kabel wie erforderlich ab siehe Verkabelungsdetails weiter unten 6 Für den Online Modus stellen Sie die BUS Adresse DIP Schalter 1 bis 4 ein Für den Online Modus stellen Sie den TERM Schalter DIP Schalter 5 nach Bedarf ein Für den Offline Modus muss der TERM Schalter ausgeschaltet sein nach oben Weitere Details finden Sie im Abschnitt mit den DIP Schaltereinstellungen 7 Be...

Page 5: ...le oder 4 Tür Controller Grün Rot Unscharf Scharf Grün wenn alle der BDT Alarmgruppe zugeordneten Bereiche unscharfgeschaltet sind oder wenn die Option Bedienteil LCD Anzeige sperrren aktiv ist Grün blinkend bei Batteriebetrieb Netzausfall oder während der Entriegelungszeit wenn der Bereich unscharfgeschaltet ist Rot wenn alle der BDT Alarmgruppe zugeordneten Bereiche scharfgeschaltet sind Rot bli...

Page 6: ...nzuzeigen oder geben Sie die Menünummer ein und drücken Sie ENTER um eine Menüoption direkt aufzurufen Menü 1 12 14 und 15 sind reservierte Menüs Menü 2 LEDs offline Wählen Sie entweder die 2 Draht Standard oder 1 Draht LED Steuerung Für die 2 Draht LED Steuerung Der braune Ader steuert die LED 1 rot scharf Ader auf Minus 0 V LED 1 rot ein Ader offen oder an 5 bis 14 V LED 1 aus Die gelbe Ader ste...

Page 7: ...S1620 1621 1622 Programmiergerät programmiert wurden Es wird das 4 Byte lange Sicherheitspasswort verwendet Datenübertragung In den folgenden Tabellen werden die Formate aufgelistet die der Kartenleser zum Übertragen von Daten verwendet Die Formate werden durch folgende Faktoren beeinflusst Online oder Offline Modus des Lesers Menü 5 Protokolloptionen Wiegand oder Magnetstreifen Menü 16 Sicherheit...

Page 8: ...Whitehorse Road Mitcham 3132 Australia EMC Technologies Pty Ltd 57 Assembly Drive Tullamarine 3043 Victoria Australia Test report reference M040929 1 IEC 60950 Test Report For ATS1197 M040929 2 Applied standards EN50130 4 1995 A1 1995 EN60950 2000 EN300330 2 v1 1 1 06 2001 Equipment class identifier RF products falling under the scope of R TTE Not Applicable X None class 1 product class 2 product ...

Reviews: