29
• Control Keypad
4.7.3
Start Settings
– Page 2
Function &
Default
Range
Unit
Description
Soft Start Curve
0(Standard)
0
(Standard)
1 !!
2 !!
3 !!
4 (Torque)
Sets ASTAT-XT’s Soft Start Curve.
4.7.3.1 on page 32.
Kickstart Time
0 Sec.
0 –1.0
sec.
Sets ASTAT-XT’s Kickstart Time.
Kickstart level is 80% Un.
Intended to start high friction loads that require high starting
torque for a short time.
A pulse of 80% Un without Current Limit is initiated to break the
load free.
Kickstart
Time
is adjustable, 0.1–1sec. After this pulse the
voltage is ramped down to
Starting Voltage
setting
before ramping up again to full voltage according to the
Start
Settings
.
26
Displays in MINIMIZED MODE and MAXIMIZED MODE.
27
When ASTAT-XT is connected in
DELTA Conf
. only
Soft Start Curve 0
(Standard) is applied.
28
There is no
Kickstart
function when ASTAT-XT is connected in
DELTA Conf.