Normal Operating Sounds

■ 

You may hear a pinging noise caused by water
being picked up and thrown against the
condenser on rainy days or when the humidity 
is high. This design feature helps remove
moisture and improve efficiency.

■ 

You may hear the thermostat click when the
compressor cycles on and off.

■ 

Water will collect in the base pan during
high humidity or on rainy days. The water
may overflow and drip from the outdoor side
of the unit.

■ 

The fan may run even when the compressor 
does not.

Problem

Possible Causes

What To Do

Air conditioner

The air conditioner

Make sure the air conditioner plug is pushed

does not start

is unplugged.

completely into the outlet.

The fuse is blown/circuit

Check the house fuse/circuit breaker box and replace

breaker is tripped.

the fuse or reset the breaker.

Power failure.

If power failure occurs, turn the air conditioner 

OFF

.

When power is restored, wait 3 minutes to restart the
air conditioner to prevent tripping of the compressor 
overload.

Air conditioner does

Airflow is restricted.

Make sure there are no curtains, blinds or furniture

not cool as it should

blocking the front of the air conditioner.

The temp control may

On models with touch pads: In 

COOL

mode, press the 

not be set correctly.

DECREASE

▼ 

pad. 

On models with control knobs, turn the temperature 
knob to a higher number. 

The air filter is dirty.

Clean the filter at least every 30 days.
See the 

Operating Instructions

section.

The room may have been hot.

When the air conditioner is first turned on, you need 
to allow time for the room to cool down.

Cold air is escaping.

Check for open furnace registers and cold air returns.

Set the air conditioner’s vent to the closed position.

Cooling coils have iced up.

See “

Air conditioner freezing up

” below.

Air conditioner

Ice blocks the air flow

On models with control knobs, set the mode control 

freezing up

and stops the air conditioner

at 

HIGH FAN 

or 

HIGH COOL

with the temp at 

1

or 

2

.

from cooling the room.

On models with touch pads, set the controls at 

HIGH FAN 

or 

HIGH COOL 

and set the thermostat to 

a higher temperature.

The remote control is 

The batteries are inserted

Check the position of the batteries. They should be 

not working

incorrectly.

inserted in the opposite (+) and (–) direction.

The batteries may be dead.

Replace the batteries.

Water drips outside

Hot, humid weather. 

This is normal.

Water drips indoors

The air conditioner is not

For proper water disposal, make sure the air conditioner

tilted to the outside.

slants slightly from the case front to the rear.

Water collects in 

Moisture removed from air 

This is normal for a short period in areas with little

base pan

and drains into base pan.

humidity; normal for a longer period in very humid areas.

“E1” appears

Function error code.

Unplug the air conditioner. Wait 3 minutes and plug it 

in the display

back in. If the error code reappears, call for service.

Summary of Contents for ASH24

Page 1: ...ir Filter 8 Batteries 8 Grille and Case 8 Outdoor Coils 8 Installation Instructions Through the Wall Installation Optional 15 Window Installation 9 14 Troubleshooting Tips 16 Normal Operating Sounds 1...

Page 2: ...must be removed prior to product disposal If you are getting rid of an old product with refrigerants check with the company handling disposal about what to do SAFETY PRECAUTIONS Do not under any circu...

Page 3: ...made to a properly grounded 2 prong wall outlet by use of a UL listed adapter available at most local hardware stores The larger slot in the adapter must be aligned with the larger slot in the wall ou...

Page 4: ...the room is unoccupied Note The fan will continue to run for a short time after the compressor cycles off OFF The fan runs all the time while the compressor cycles on and off This switch must be set...

Page 5: ...door air will become cooler Set the thermostat at a higher number and the indoor air will become warmer NOTE If the air conditioner is off and is then turned on while set to COOL it will take approxim...

Page 6: ...at midpoint For Maximum Cooling Select HIGH COOL with the temp control at the highest number available on your knob For Quieter and Nighttime Cooling Select LOW COOL with the temp control at midpoint...

Page 7: ...o the left Energy Saver on some models The energy saver switch controls the fan ON The fan and compressor cycle on and off together This results in wider variations of room temperature and humidity It...

Page 8: ...t batteries Do not use rechargeable batteries Remove the batteries from the remote control if the system is not going to be used for a long time 3 2 1 Air Filter The air filter behind the front grille...

Page 9: ...e power cord Do not change the plug on the power cord of this air conditioner Aluminum house wiring may present special problems consult a qualified electrician Before You Begin Some models require 11...

Page 10: ...to Install the Air Conditioner before beginning Parts Included Window Installation Instructions Type A 22 Security bracket Top mounting rail Right accordion panel Foam top window gasket Window sash se...

Page 11: ...behind it if present that holds the grille in place On models with a raise up inlet grille lift it see the Care and Cleaning section and remove the screw behind it if present that holds the grille in...

Page 12: ...bottom mounting rails Attach the accordion panels to the side of the case using 8 type A screws B A Remove the Air Conditioner From the Case Remove the 2 screws on each side of the case Keep these fo...

Page 13: ...ide wall Attach a V support to each side of the bottom of the case using type A screws 4 on each side Adjust the type C leveling bolts against the outside wall so that the case has a slight tilt to th...

Page 14: ...in until it snaps into place Secure the front grille to the case by replacing the screw removed in Step 3A If a screw was not removed in Step 3A secure the grille with a Type D screw for models with a...

Page 15: ...ertain a wall receptacle is available close to the hole location or make arrangements to install a receptacle Place the case in the wall opening and secure with 12 1 long 10 wood screws NOTE Drill pil...

Page 16: ...de press the not be set correctly DECREASE pad On models with control knobs turn the temperature knob to a higher number The air filter is dirty Clean the filter at least every 30 days See the Operati...

Page 17: ...protection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher washer and dryer range TV VCR and much mo...

Page 18: ...ure that your product is registered or register online at www GEAppliances com 1 2 3 Model Number Serial Number Cut here Complete and mail your Consumer Product Ownership Registration today Have the p...

Page 19: ...vide reasonable and necessary maintenance In commercial locations labor necessary to move the unit to a location where it is accessible for service by an individual technician Replacement of house fus...

Page 20: ...arranty and learn about special discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Ho...

Page 21: ...ciones de instalaci n Instalaci n en ventanas 11 14 Instalaci n opcional a trav s de la pared 15 Solucionar problemas 16 Sonidos normales de operaci n 16 Servicio al consumidor Garant a 19 Servicio al...

Page 22: ...tes los que por Ley Federan deben ser removidos antes de desecharlos Si usted planea deshacerse de alg n producto que contenga refrigerantes p ngase en contacto con la compa a que se encarga de recoge...

Page 23: ...disponible en la mayor a de las ferreter as La ranura mayor en el adaptador debe estar alineada con la p a mayor en la pared para proporcionar una polaridad apropiada en la conexi n del cable el ctric...

Page 24: ...lo de apagado OFF APAGADO El ventilador funciona todo el tiempo mientras que el compresor pasa por los ciclos de encendido y apagado Este interruptor debe estar en OFF APAGADO para usar los ajustes de...

Page 25: ...ra del aire interno se calentar m s NOTA Si el acondicionador de aire est apagado y luego se enciende mientras est ajustado en COOL FR O tomar aproximadamente 3 minutos para que el compresor comience...

Page 26: ...GH COOL ENFRIAMIENTO ALTO o MED COOL ENFRIAMIENTO MEDIO con el control de temperatura en el medio Para enfriamiento m ximo Seleccione HIGH COOL ENFRIAMIENTO ALTO con el control de temperatura en el n...

Page 27: ...en ciclo entre encendido y apagado Esto da como resultado mayores variaciones de temperaturas y humedad en la habitaci n Normalmente este es usado cuando la habitaci n no est ocupada OFF APAGADO El ve...

Page 28: ...per odo prolongado 3 2 1 Servicio al consumidor Solucionar problemas Operaci n Seguridad Instalaci n Filtro de aire El filtro de aire detr s de la rejilla frontal debe inspeccionarse y limpiarse por l...

Page 29: ...nsulte a un t cnico electricista calificado Antes de comenzar Algunos modelos requieren tomacorrientes de 115 120 voltios de corriente alterna y 60 Hz conectados a tierra protegidos con un fusible de...

Page 30: ...d Riel de montaje superior Panel de acorde n derecho Parte superior de la espuma de la junta de la ventana Banda de sello de la ventana Panel de acorde n izquierdo Tipo B 11 Tipo C 2 Junta de la caja...

Page 31: ...l proceso para otros tipos de ventanas El acondicionador de aire puede instalarse sin los paneles de acorde n para ajustarse a una ventana m s estrecha Ver las dimensiones de la abertura de la ventana...

Page 32: ...ador de aire de la caja Retire los 2 tornillos en cada lado de la caja Gu rdelos para m s tarde Deslice el acondicionador de a re de la caja agarrando la empu adura del c rter base y tire hacia adelan...

Page 33: ...os tornillos de nivelado tipo C contra la pared exterior para que la caja tenga una ligera inclinaci n hacia afuera Use un nivel aproximadamente 1 2 burbuja ser la inclinaci n correcta hacia afuera NO...

Page 34: ...egure la parrilla con un tornillo tipo D para los modelos con parrilla de entrada elevadiza o 1 2 tornillos tipo D para modelos con un filtro deslizable La instalaci n est ahora completa D C B A Gu e...

Page 35: ...piloto si es necesario para una instalaci n apropiada Si el marco es demasiado grande use cu as para evitar la distorsi n de la caja C B A 1 La caja podr a instalarse a trav s de la pared en construcc...

Page 36: ...la tecla DECREASE En los modelos con botones gire la temperatura a un n mero mayor El filtro de aire est sucio Limpie el filtro cada 30 d as por lo menos Ver la secci n de Instrucciones de Operaci n...

Page 37: ...17 Notas Servicio al consumidor Solucionar problemas Operaci n Seguridad Instalaci n...

Page 38: ...18 Servicio al consumidor Solucionar problemas Operaci n Seguridad Instalaci n Notas...

Page 39: ...y necesario En locales comerciales la mano de obra necesaria para retirar la unidad hacia un lugar para revisi n por parte de un t cnico individual Reemplazo de fusibles de la casa o reajuste del sist...

Page 40: ...etalles sobre descuentos especiales disponibles mientras su garant a est a n activa Puede comprarla en l nea en cualquier momento o llamar al 800 626 2224 durante horas normales de oficina GE Consumer...

Reviews: