Care and cleaning of the air conditioner.

Air Filter

The air filter behind the front grille should be
checked and cleaned at least every 30 days or
more often if necessary.

To remove: 

Grasp the filter handle and pull it up and out.

The filter can be cleaned with a vacuum
cleaner to remove light dust or washed in
warm, soapy water. Rinse and let the filter dry
before replacing it.

Do not

expose the filter to

heat or direct sunlight when drying.

CAUTION: 

DO NOT operate the air conditioner 

without a filter because dirt and lint will clog it and
reduce performance.

Outdoor Coils

The coils on the outdoor side of the air
conditioner should be checked regularly. 
If they are clogged with dirt or soot they may
be professionally steam cleaned, a service
available through your GE service outlet.

Grille and Case

Turn the air conditioner off and remove the
plug from the wall outlet before cleaning. 

To clean, use water and a mild detergent. 
Do not use bleach or abrasives.

Summary of Contents for ASC05 Series

Page 1: ...door Coils 6 Air Filter 6 Installation Instructions Window Installation 7 11 Troubleshooting Tips Before You Call For Service 12 Normal Operating Sounds 12 Customer Service Product Registration 13 14 Warranty 15 Service Telephone Numbers 2 Back Cover GE Appliances Air Conditioners 49 7385 1 JR 12 99 ASC05 5 000 BTU models Owner s Manual Installation Instructions www geappliances com E DB68 01037A ...

Page 2: ...ey over the life of your air conditioner READ THIS MANUAL IF YOU NEED SERVICE You ll find many answers to common problems in the Before You Call For Service section If you review our chart of Troubleshooting Tips first you may not need to call for service at all If you do need service you can relax knowing help is only a phone call away A list of toll free customer service numbers is included in t...

Page 3: ...s in the vicinity of this or any other appliance SAFETY PRECAUTIONS 3 Customer Service Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be properly grounded The power cord of this appliance is equipped with a 3 prong grounding plug...

Page 4: ...rary connection may be made to a properly grounded 2 prong wall outlet by use of a UL listed adapter available at most local hardware stores The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord When disconnecting the power cord from the adapter always hold the adapter in place with one hand while pulli...

Page 5: ...with the temp control at midpoint For Maximum Cooling Select HI COOL with the temp control at the highest number available on the knob For Quieter Nighttime Cooling Select LOW COOL with the temp control at midpoint Temp Control The temp control is used to maintain the room temperature The compressor will cycle on and off to keep the room at the same level of comfort When you turn the knob to a hig...

Page 6: ...t up and out The filter can be cleaned with a vacuum cleaner to remove light dust or washed in warm soapy water Rinse and let the filter dry before replacing it Do not expose the filter to heat or direct sunlight when drying CAUTION DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance Outdoor Coils The coils on the outdoor side of the air co...

Page 7: ...ower cord Do not change the plug on the power cord of this air conditioner Aluminum house wiring may present special problems consult a qualified electrician Before You Begin Some models require 115 120 volt a c 60 Hz grounded outlet protected with a 15 amp time delay fuse or circuit breaker The 3 prong grounding plug minimizes the possibility of electric shock hazard If the wall outlet you plan t...

Page 8: ...acket 2 183 4 min Without accordion panels Window Requirements These instructions are for a standard double hung window You will need to modify them for other types of windows The air conditioner can be installed without the accordion panels if needed to fit in a narrow window See the window opening dimensions at right All supporting parts must be secured to firm wood masonry or metal The electric...

Page 9: ...t for this attach a piece of wood to the stool WOOD PIECES WIDTH 2 LENGTH Long enough to fit inside the window frame THICKNESS To determine the thickness place a piece of wood on the stool to make it 1 2 higher than the top of the storm window frame Attach securely with nails or screws provided by the installer 1 2 higher than frame Storm window frame Wood Stool 2 4 Stool Type B screws Outside Ins...

Page 10: ...wer the window behind the top mounting rail The air conditioner should be slightly tilted to the outside B A 5 Lower the window Front grille Inside Outside Install the Window Accordion Panels and Locking Bracket Extend the left and right accordion panels to the vertical window sashes and attach the top corners with two type B screws Use a lower accordion panel clamp on each lower corner to trap th...

Page 11: ...oner off and disconnect the power cord Wait 5 10 minutes before moving the air conditioner to allow the water to drain from the coil into the base pan Remove the foam gasket from between the windows Remove the window locking bracket Remove the screws securing the accordion panels on each side Close the accordion panels Keeping a firm grip on the air conditioner raise the window and carefully rock ...

Page 12: ...e air conditioner plug is pushed does not start is unplugged completely into the outlet The fuse is blown circuit Check the house fuse circuit breaker box and replace breaker is tripped the fuse or reset the breaker Power failure If power failure occurs turn the mode control to OFF When power is restored wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload A...

Page 13: ...otection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher washer and dryer range TV VCR and much more any brand Plus there s no extra charge for emergency service and low monthly financing is available Even icemaker coverage and food spoilage protection is offered You can rest easy knowing that all y...

Page 14: ...or register online at www geappliances com 1 2 3 Model Number Serial Number Cut here Complete and mail your Consumer Product Ownership Registration today Have the peace of mind of knowing we can contact you in the unlikely event of a safety modification After mailing the registration below store this document in a safe place It contains information you will need should you require service Our serv...

Page 15: ...our dealer or installer You are responsible for providing adequate electrical connecting facilities Failure of the product resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance In commercial locations labor necessary to move the unit to a location where it is accessible for service by an individual technician Replac...

Page 16: ...l discount GE Consumer Service will still be there after your warranty expires Parts and Accessories 800 626 2002 Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are accepted Instructions contained in this manual cover procedures to be performed by any user Other servicing generally should be referr...

Reviews: