Ordering Information

Maintaining the Detector

When installed and used properly, the AP950PI provides many years
of service with minimal maintenance. To ensure proper operation,
you should walk test the unit annually.

Clean the inside of the unit with a soft bristled brush or compressed
air. Clean the outside with a damp (water) cloth as  needed to keep it
free of dust and dirt. Always test the unit after cleaning.

Model Number

Description

AP950PI

PIR,  closed loop, Form A, 35 foot (10.7m) pet immune mirror installed, 50 foot (15.2m) standard mirror
included

Specifications

Input voltage ............................................................. 8.2 to 15VDC
Input voltage (UL) ...............................................  9.7 to 13.6 VDC
Peak to peak ripple ...........................................  2V max at 12VDC
Current consumption ..................................................... 17mA max
Mounting height ............................................ 7' to 10' (2.1m to 3m)
Relay contacts .................................................... 50 mA max at 28V
Relay type ..................................................  Closed loop (Form A)
Alarm time (LED and relay) ............................... 2.9 to 3.5 seconds
Operating temperature .......................  0° to 122° F (-18° to 50° C)
Relative humidity ..........................................  93% non-condensing
RFI immunity ........................   -  20V/meter from 28 to 1000MHz
Weight ....................................................................  0.26 lbs (120 g)
Dimensions:

Width .................................................................... 2.9" (7.4 cm)
Depth .................................................................. .2.1" (5.2 cm)
Height ................................................................  4.7" (12.0 cm)

Number of curtains .......................................................................  9
View angle .................................................................................  89°
Detection range ............................ 50' (15.2m) with standard mirror

                                                    and sensitivity set to Increased
                                            35' (10.7m) with pet immune mirror
                                                      and sensitivity set to Standard

Listings ............................................................................. C-UL US

>

  1037263 Rev B     06/02

Dimensions

4.7"
12.0cm

2.9"
7.4cm

2.1"
5.2cm

12345 SW Leveton Drive

Tualatin, OR 97062

www.interlogixsecurity.com

www.sentrol.com
©  2002 GE Interlogix, Inc.

Phone: 503-692-4052

USA & Canada: 800-547-2556

Technical Service: 800-648-7424

FaxBack: 800-483-2495

GE Interlogix

 

Operation Information

When the unit is powered up, the LED turns on and the relay
contacts open for about 12 seconds, then the LED goes off and the
relay contacts close. Thereafter, the LED will turn on and the relay
contacts will open every time an alarm occurs. The unit should be
allowed to settle for at least one minute after power-up before walk
testing. When walk testing, walk across the curtains, not directly
toward or away from the unit. Wait 10 seconds between trips to
allow the unit to stabilize.

Summary of Contents for AP950PI - Security High-Security PIR Motion Sensor

Page 1: ...id vibration free surface Mount the unit so the expected movement of an intruder is across the fields of the detection pattern See Figure 2 Do not locate the unit on a surface exposed to moisture Do not locate the unit where it may be exposed to false alarm sources such as direct sunlight heat sources heaters radiators etc in the field of view strong air drafts fans air conditioners etc on unit Do...

Page 2: ...using toward the back housing to snap the unit closed See Figure 1 9 Fasten the housings together with the screw provided Selecting the Coverage Pattern The coverage pattern for the unit can be modified to fit specific applications by masking off mirror curtains Curtains should be masked to avoid sources of false alarms such as heaters air conditioners and windows Remove the mirror by inserting a ...

Page 3: ... to place the unit in Bi Curtain Mode STD Standard Curtain Mode Use for wide angle or single curtain applications Requires the intruder to only pass through one curtain to trigger an alarm Either pin can be uncovered to place the unit in Standard Curtain Mode Note Operation of the AP950PI in the Standard Curtain Mode is UL 639 Listed for a range of 35 feet 10 7m with both mirrors in Standard Sensi...

Page 4: ... to 122 F 18 to 50 C Relative humidity 93 non condensing RFI immunity 20V meter from 28 to 1000MHz Weight 0 26 lbs 120 g Dimensions Width 2 9 7 4 cm Depth 2 1 5 2 cm Height 4 7 12 0 cm Number of curtains 9 View angle 89 Detection range 50 15 2m with standard mirror and sensitivity set to Increased 35 10 7m with pet immune mirror and sensitivity set to Standard Listings C UL US 1037263 Rev B 06 02 ...

Reviews: