THROUGH-THE-WALL INSTALLATION
4. INSTALL THE CASE IN THE WALL.
•
Place the case in the wall opening.
•
Secure the case sides and top to the wooden
frame.
NOTE:
Drill holes in the case sides and top, if
necessary, for proper installation. If the frame is
oversized, use shims to prevent cabinet distortion.
•
Caulk all four sides on the outdoor side of the
case to prevent moisture from getting through
to the interior wall. Use of flashing will further
prevent moisture from getting into interior walls.
•
Install wood trim molding, if desired, around the
roomside projection of the case.
3. REMOVE THE AIR CONDITIONER
AND PREPARE THE CASE.
NOTE:
Save these screws. They will be used at
the end of the installation.
•
Remove the air conditioner from the case using
the base pan as a handle.
•
With caulking compound or electrical tape,
seal all holes provided in the case for window
installation hardware not used in this installation.
Remove the
air conditioner
locking screws.
Use four 1
″
long #10 wood screws.
Use six 1
″
long #10
wood screws.
Remove the
locking brackets.
Remove the
ground screw
and move the
ground wire
aside.
Secure the case bottom
rail to the wooden frame
with two 1
″
long #10
wood screws.
Plaster
line
Trim
molding
(if desired)
Holes for #10
1
″
long wood
screws
Caulking
Flashing
1
″
min.
Inside
Sill channel
Brick veneer
Lintel angle
(if required)
Caulking
Remove the
knobs and
the control
panel.
Summary of Contents for AMH06