Installer Programming Menus
20
Siren (lst Tier)
The SIREN menu allows you to set up the following siren options:
•
SIREN TIME OUT
•
TROUBLE BEEPS
•
ALARM VOLUME
AC FAIL
(2nd Tier)
(REPORTS—)
(Default = off, UL installations = on)
When AC Failure is on, the panel reports to the central station 15 minutes after AC power to
the panel is lost.
¾
To turn AC failure reports on or off:
Press
#
to turn on or off.
LOW CPU BATTERY
(2nd Tier)
(REPORTS—)
Note
Panel will not call in a low CPU
battery within the first 24 hours
of being powered up.
(Default = on, UL installations = on)
When this setting is on, the panel reports a low panel battery to the central station.
¾
To turn low CPU battery reports on or off:
Press
#
to turn on or off.
PHONE TEST
(2nd Tier)
(REPORTS—)
(Default = on)
This setting determines if the user can, at any time when disarmed, test the communication
between the panel and the central station. If a DTIM is installed with the system:
•
The panel sends a packet to the DTIM informing it to send a phone test report to the central
station. The report will be sent out immediately.
•
The DTIM will send a successful or failed phone test message to the panel.
•
The panel will display
PHONE
TEST
FAILURE
, if the phone test is unsuccessful.
•
The panel will display
TEST
PASS
, if the phone test is successful.
•
If a central station phone number is not programmed the panel will not display the option to
do a phone test.
•
If a DTIM is not enrolled the panel will not display the option to do a phone test.
•
High or Low level reporting must be on.
¾
To turn the phone test setting on or off:
Press
#
to turn on or off.
SIREN TIME OUT
(2nd Tier)
(SIRENS—)
(Default = 4 minutes, Parameters = 1-30, UL installations = 4 minutes)
Siren Time-out determines how long sirens sound if no one is present to disarm the system.
¾
To set Siren Time Out:
Press
#
, enter the desired time and then press #.
TROUBLE BEEPS
(2nd Tier)
(SIRENS—)
(Default = on, UL installations = on)
When this setting is on, the panel will beep to alert users of system trouble.
¾
To turn Trouble Beeps on or off:
Press
#
to turn on or off.
Summary of Contents for Allegro 60-874-95R
Page 6: ...iv...